Robert Huhle
Dresden University of Technology
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Robert Huhle.
BJA: British Journal of Anaesthesia | 2016
T Kiss; Pedro Luis do Nascimento Silva; Robert Huhle; Lillian Moraes; Raquel S. Santos; Nathane S. Felix; Cintia L. Santos; Marcelo M. Morales; Vera L. Capelozzi; Michael Kasper; Paolo Pelosi; M. Gama de Abreu; Prm Rocco
BACKGROUND Variable ventilation improves respiratory function, but it is not known whether the amount of variability in tidal volume (VT) can be reduced in recruited lungs without a deterioration of respiratory system elastance. METHODS Acute lung inflammation was induced by intratracheal instillation of lipopolysaccharide in 35 Wistar rats. Twenty-eight animals were anaesthetized and ventilated in volume-controlled mode. Lungs were recruited by random variation of VT (mean 6 ml kg(-1), coefficient of variation 30%, normal distribution) for 30 min. Animals were randomly assigned to different amounts of VT variability (n=7 for 90 min per group): 30, 15, 7.5, or 0%. Lung function, diffuse alveolar damage, and gene expression of biological markers associated with cell mechanical stress, inflammation, and fibrogenesis were assessed. Seven animals were not ventilated and served as controls for post-mortem analyses. RESULTS A VT variability of 30%, but not 15, 7.5, or 0%, prevented deterioration of respiratory system elastance [Mean (SD) -7.5 (8.7%), P<0.05; 21.1 (9.6%), P<0.05; 43.3 (25.9), P<0.05; and 41.2 (16.4), P<0.05, respectively]. Diffuse alveolar damage was lower with a VT variability of 30% than with 0% and without ventilation, because of reduced oedema and haemorrhage. A VT variability of 30, 15, or 7.5% reduced the gene expression of amphiregulin, cytokine-induced neutrophil chemoattractant-1, and tumour necrosis factor α compared with a VT variability of 0%. CONCLUSIONS In this model of acute lung inflammation, a VT variability of 30%, compared with 15 and 7.5%, was necessary to avoid deterioration of respiratory system elastance and was not associated with lung histological damage.
Anesthesiology | 2015
Peter M. Spieth; Pedro L. Silva; Cristiane S. N. B. Garcia; Debora S. Ornellas; Cynthia S. Samary; Lillian Moraes; Maira Bentes; Marcelo M. Morales; Michael Kasper; Andreas Güldner; Robert Huhle; Thea Koch; Paolo Pelosi; Marcelo Gama de Abreu; Patricia R.M. Rocco
Background:Mechanical ventilation can lead to lung biotrauma when mechanical stress exceeds safety thresholds. The authors investigated whether the duration of mechanical stress, that is, the impact of a stress versus time product (STP), influences biotrauma. The authors hypothesized that higher STP levels are associated with increased inflammation and with alveolar epithelial and endothelial cell injury. Methods:In 46 rats, Escherichia coli lipopolysaccharide (acute lung inflammation) or saline (control) was administered intratracheally. Both groups were protectively ventilated with inspiratory-to-expiratory ratios 1:2, 1:1, or 2:1 (n = 12 each), corresponding to low, middle, and high STP levels (STPlow, STPmid, and STPhigh, respectively). The remaining 10 animals were not mechanically ventilated. Results:In animals with mild acute lung inflammation, but not in controls: (1) messenger RNA expression of interleukin-6 was higher in STPhigh (28.1 ± 13.6; mean ± SD) and STPlow (28.9 ± 16.0) versus STPmid (7.4 ± 7.5) (P < 0.05); (2) expression of the receptor for advanced glycation end-products was increased in STPhigh (3.6 ± 1.6) versus STPlow (2.3 ± 1.1) (P < 0.05); (3) alveolar edema was decreased in STPmid (0 [0 to 0]; median, Q1 to Q3) compared with STPhigh (0.8 [0.6 to 1]) (P < 0.05); and (4) expressions of vascular cell adhesion molecule-1 and intercellular adhesion molecule-1 were higher in STPlow (3.0 ± 1.8) versus STPhigh (1.2 ± 0.5) and STPmid (1.4 ± 0.7) (P < 0.05), respectively. Conclusions:In the mild acute lung inflammation model used herein, mechanical ventilation with inspiratory-to-expiratory of 1:1 (STPmid) minimized lung damage, whereas STPhigh increased the gene expression of biological markers associated with inflammation and alveolar epithelial cell injury and STPlow increased markers of endothelial cell damage.
Critical Care | 2016
Robert Huhle; Paolo Pelosi; Marcelo Gama de Abreu
This article is one of ten reviews selected from the Annual Update in Intensive Care and Emergency medicine 2016. Other selected articles can be found online at http://www.biomedcentral.com/collections/annualupdate2016. Further information about the Annual Update in Intensive Care and Emergency Medicine is available from http://www.springer.com/series/8901.
Critical Care Medicine | 2016
Cynthia S. Samary; Lillian Moraes; Cintia L. Santos; Robert Huhle; Raquel S. Santos; Debora S. Ornellas; Nathane S. Felix; Vera Luiza Capelozzi; Alberto Schanaider; Paolo Pelosi; Marcelo Gama de Abreu; Patricia R.M. Rocco; Pedro L. Silva
Objectives: The biologic effects of variable ventilation may depend on the etiology of acute respiratory distress syndrome. We compared variable and conventional ventilation in experimental pulmonary and extrapulmonary acute respiratory distress syndrome. Design: Prospective, randomized, controlled experimental study. Settings: University research laboratory. Subjects: Twenty-four Wistar rats. Interventions: Acute respiratory distress syndrome was induced by Escherichia coli lipopolysaccharide administered intratracheally (pulmonary acute respiratory distress syndrome, n = 12) or intraperitoneally (extrapulmonary acute respiratory distress syndrome, n = 12). After 24 hours, animals were randomly assigned to receive conventional (volume-controlled ventilation, n = 6) or variable ventilation (n = 6). Nonventilated animals (n = 4 per etiology) were used for comparison of diffuse alveolar damage, E-cadherin, and molecular biology variables. Variable ventilation was applied on a breath-to-breath basis as a sequence of randomly generated tidal volume values (n = 600; mean tidal volume = 6 mL/kg), with a 30% coefficient of variation (normal distribution). After randomization, animals were ventilated for 1 hour and lungs were removed for histology and molecular biology analysis. Measurements and Main Results: Variable ventilation improved oxygenation and reduced lung elastance compared with volume-controlled ventilation in both acute respiratory distress syndrome etiologies. In pulmonary acute respiratory distress syndrome, but not in extrapulmonary acute respiratory distress syndrome, variable ventilation 1) decreased total diffuse alveolar damage (median [interquartile range]: volume-controlled ventilation, 12 [11–17] vs variable ventilation, 9 [8–10]; p < 0.01), interleukin-6 expression (volume-controlled ventilation, 21.5 [18.3–23.3] vs variable ventilation, 5.6 [4.6–12.1]; p < 0.001), and angiopoietin-2/angiopoietin-1 ratio (volume-controlled ventilation, 2.0 [1.3–2.1] vs variable ventilation, 0.7 [0.6–1.4]; p < 0.05) and increased relative angiopoietin-1 expression (volume-controlled ventilation, 0.3 [0.2–0.5] vs variable ventilation, 0.8 [0.5–1.3]; p < 0.01). In extrapulmonary acute respiratory distress syndrome, only volume-controlled ventilation increased vascular cell adhesion molecule-1 messenger RNA expression (volume-controlled ventilation, 7.7 [5.7–18.6] vs nonventilated, 0.9 [0.7–1.3]; p < 0.05). E-cadherin expression in lung tissue was reduced in volume-controlled ventilation compared with nonventilated regardless of acute respiratory distress syndrome etiology. In pulmonary acute respiratory distress syndrome, E-cadherin expression was similar in volume-controlled ventilation and variable ventilation; in extrapulmonary acute respiratory distress syndrome, however, it was higher in variable ventilation than in volume-controlled ventilation. Conclusions: Variable ventilation improved lung function in both pulmonary acute respiratory distress syndrome and extrapulmonary acute respiratory distress syndrome. Variable ventilation led to more pronounced beneficial effects in biologic marker expressions in pulmonary acute respiratory distress syndrome compared with extrapulmonary acute respiratory distress syndrome but preserved E-cadherin in lung tissue only in extrapulmonary acute respiratory distress syndrome, thus suggesting lower damage to epithelial cells.
PLOS ONE | 2014
Alessandro Beda; Andreas Güldner; Alysson R. Carvalho; Walter A. Zin; Nadja C. Carvalho; Robert Huhle; Antonio Giannella-Neto; Thea Koch; Marcelo Gama de Abreu
Background Measuring esophageal pressure (Pes) using an air-filled balloon catheter (BC) is the common approach to estimate pleural pressure and related parameters. However, Pes is not routinely measured in mechanically ventilated patients, partly due to technical and practical limitations and difficulties. This study aimed at comparing the conventional BC with two alternative methods for Pes measurement, liquid-filled and air-filled catheters without balloon (LFC and AFC), during mechanical ventilation with and without spontaneous breathing activity. Seven female juvenile pigs (32–42 kg) were anesthetized, orotracheally intubated, and a bundle of an AFC, LFC, and BC was inserted in the esophagus. Controlled and assisted mechanical ventilation were applied with positive end-expiratory pressures of 5 and 15 cmH2O, and driving pressures of 10 and 20 cmH2O, in supine and lateral decubitus. Main Results Cardiogenic noise in BC tracings was much larger (up to 25% of total power of Pes signal) than in AFC and LFC (<3%). Lung and chest wall elastance, pressure-time product, inspiratory work of breathing, inspiratory change and end-expiratory value of transpulmonary pressure were estimated. The three catheters allowed detecting similar changes in these parameters between different ventilation settings. However, a non-negligible and significant bias between estimates from BC and those from AFC and LFC was observed in several instances. Conclusions In anesthetized and mechanically ventilated pigs, the three catheters are equivalent when the aim is to detect changes in Pes and related parameters between different conditions, but possibly not when the absolute value of the estimated parameters is of paramount importance. Due to a better signal-to-noise ratio, and considering its practical advantages in terms of easier calibration and simpler acquisition setup, LFC may prove interesting for clinical use.
Anesthesiology | 2015
Andreas Güldner; Thomas Kiss; Thomas Bluth; Christopher Uhlig; Anja Braune; Nadja C. Carvalho; Theresa Quast; Ines Rentzsch; Robert Huhle; Peter M. Spieth; Torsten Richter; Felipe Saddy; Patricia R.M. Rocco; Michael Kasper; Thea Koch; Paolo Pelosi; Marcelo Gama de Abreu
Background:To investigate the role of ultraprotective mechanical ventilation (UP-MV) and extracorporeal carbon dioxide removal with and without spontaneous breathing (SB) to improve respiratory function and lung protection in experimental severe acute respiratory distress syndrome. Methods:Severe acute respiratory distress syndrome was induced by saline lung lavage and mechanical ventilation (MV) with higher tidal volume (VT) in 28 anesthetized pigs (32.8 to 52.5 kg). Animals (n = 7 per group) were randomly assigned to 6 h of MV (airway pressure release ventilation) with: (1) conventional P-MV with VT ≈6 ml/kg (P-MVcontr); (2) UP-MV with VT ≈3 ml/kg (UP-MVcontr); (3) UP-MV with VT ≈3 ml/kg and SB (UP-MVspont); and (4) UP-MV with VT ≈3 ml/kg and pressure supported SB (UP-MVPS). In UP-MV groups, extracorporeal carbon dioxide removal was used. Results:The authors found that: (1) UP-MVcontr reduced diffuse alveolar damage score in dorsal lung zones (median[interquartile]) (12.0 [7.0 to 16.8] vs. 22.5 [13.8 to 40.8]), but worsened oxygenation and intrapulmonary shunt, compared to P-MVcontr; (2) UP-MVspont and UP-MVPS improved oxygenation and intrapulmonary shunt, and redistributed ventilation towards dorsal areas, as compared to UP-MVcontr; (3) compared to P-MVcontr, UP-MVcontr and UP-MVspont, UP-MVPS yielded higher levels of tumor necrosis factor-&agr; (6.9 [6.5 to 10.1] vs. 2.8 [2.2 to 3.0], 3.6 [3.0 to 4.7] and 4.0 [2.8 to 4.4] pg/mg, respectively) and interleukin-8 (216.8 [113.5 to 343.5] vs. 59.8 [45.3 to 66.7], 37.6 [18.8 to 52.0], and 59.5 [36.1 to 79.7] pg/mg, respectively) in dorsal lung zones. Conclusions:In this model of severe acute respiratory distress syndrome, MV with VT ≈3 ml/kg and extracorporeal carbon dioxide removal without SB slightly reduced lung histologic damage, but not inflammation, as compared to MV with VT = 4 to 6 ml/kg. During UP-MV, pressure supported SB increased lung inflammation.
Experimental Lung Research | 2014
Robert Huhle; Peter M. Spieth; Andreas Güldner; Thea Koch; Marcelo Gama de Abreu
ABSTRACT Background: This study aimed to develop and evaluate an adaptive control system for volume-controlled ventilation (VCV) in small animals to guarantee accurate delivery of tidal volume (VT) in the presence of changes in lung mechanics. Methods: The adaptive control system to control the Harvard Inspira ventilator was designed and evaluated on a custom-made physical model during step changes of resistance and elastance of the respiratory system assessing difference in minute ventilation (ΔMVc) during convergence cycles (NC). The controller was then evaluated during conventional and variable volume VCV in rats with acute respiratory distress syndrome (ARDS) induced by intratracheal HCl (six animals/group), where the difference between desired and applied VT (dVT,d), its root-mean square error (RMSE) and relative deviation from target minute ventilation (ΔMV) were determined. Results: The controller showed fast convergence NC < 20 cycles with an acceptable ΔMVC < 10% in simulations and nearly abolished dVT,d (VCV: 0.23 ± 0.1 mL to 0.0 ± 0.0 mL, P < .001 and vVCV: 0.05 ± 0.8 mL to 0.0 ± 0.0 mL, P < .001), significantly reduced RMSE (VCV: 0.23 ± 0.1 to 0.04 ± 0.01 mL, P < .001 and vVCV: 0.13 ± 0.04 to 0.08 ± 0.02 mL, P < .001) and ΔMV (VCV: 11.6 ± 4.2 to 0.04 ± 0.15%, P < .001 and vVCV: −3 ± 3.8 to −0.35 ± 1.3 %, P < .001) in animal experiments. In VCV the improvement was more pronounced, due to reduced respiratory system elastance in this group (VCV: 5.6 cmH2O mL−1 versus vVCV: 3.8 cmH2O mL−1, P < .001). Conclusions: The new adaptive controller ensured accurate delivery of VT in VCV and proved valuable for mechanical ventilation of small animals especially in ARDS research.
Frontiers in Physiology | 2016
Isabela Henriques; Gisele A. Padilha; Robert Huhle; Caio Wierzchon; Pj Miranda; Isalira Peroba Ramos; Nazareth N. Rocha; Fernanda F. Cruz; Raquel S. Santos; Milena V. de Oliveira; Sergio Augusto Lopes de Souza; Regina Coeli dos Santos Goldenberg; Ronir Raggio Luiz; Paolo Pelosi; Marcelo Gama de Abreu; Pedro L. Silva; Patricia R.M. Rocco
Emphysema is characterized by loss of lung tissue elasticity and destruction of structures supporting alveoli and capillaries. The impact of mechanical ventilation strategies on ventilator-induced lung injury (VILI) in emphysema is poorly defined. New ventilator strategies should be developed to minimize VILI in emphysema. The present study was divided into two protocols: (1) characterization of an elastase-induced emphysema model in rats and identification of the time point of greatest cardiorespiratory impairment, defined as a high specific lung elastance associated with large right ventricular end-diastolic area; and (2) comparison between variable (VV) and conventional volume-controlled ventilation (VCV) on lung mechanics and morphometry, biological markers, and cardiac function at that time point. In the first protocol, Wistar rats (n = 62) received saline (SAL) or porcine pancreatic elastase (ELA) intratracheally once weekly for 4 weeks, respectively. Evaluations were performed 1, 3, 5, or 8 weeks after the last intratracheal instillation of saline or elastase. After identifying the time point of greatest cardiorespiratory impairment, an additional 32 Wistar rats were randomized into the SAL and ELA groups and then ventilated with VV or VCV (n = 8/group) [tidal volume (VT) = 6 mL/kg, positive end-expiratory pressure (PEEP) = 3 cmH2O, fraction of inspired oxygen (FiO2) = 0.4] for 2 h. VV was applied on a breath-to-breath basis as a sequence of randomly generated VT values (mean VT = 6 mL/kg), with a 30% coefficient of variation. Non-ventilated (NV) SAL and ELA animals were used for molecular biology analysis. The time point of greatest cardiorespiratory impairment, was observed 5 weeks after the last elastase instillation. At this time point, interleukin (IL)-6, cytokine-induced neutrophil chemoattractant (CINC)-1, amphiregulin, angiopoietin (Ang)-2, and vascular endothelial growth factor (VEGF) mRNA levels were higher in ELA compared to SAL. In ELA animals, VV reduced respiratory system elastance, alveolar collapse, and hyperinflation compared to VCV, without significant differences in gas exchange, but increased right ventricular diastolic area. Interleukin-6 mRNA expression was higher in VCV and VV than NV, while surfactant protein-D was increased in VV compared to NV. In conclusion, VV improved lung function and morphology and reduced VILI, but impaired right cardiac function in this model of elastase induced-emphysema.
Anesthesia & Analgesia | 2017
Lígia de Albuquerque Maia; Cynthia S. Samary; Milena V. de Oliveira; Cintia L. Santos; Robert Huhle; Vera Luiza Capelozzi; Marcelo M. Morales; Marcus J. Schultz; Marcelo Gama de Abreu; Paolo Pelosi; Pedro Luis do Nascimento Silva; Patricia Rieken Macedo Rocco
BACKGROUND: Intraoperative mechanical ventilation may yield lung injury. To date, there is no consensus regarding the best ventilator strategy for abdominal surgery. We aimed to investigate the impact of the mechanical ventilation strategies used in 2 recent trials (Intraoperative Protective Ventilation [IMPROVE] trial and Protective Ventilation using High versus Low PEEP [PROVHILO] trial) on driving pressure (&Dgr;PRS), mechanical power, and lung damage in a model of open abdominal surgery. METHODS: Thirty-five Wistar rats were used, of which 28 were anesthetized, and a laparotomy was performed with standardized bowel manipulation. Postoperatively, animals (n = 7/group) were randomly assigned to 4 hours of ventilation with: (1) tidal volume (VT) = 7 mL/kg and positive end-expiratory pressure (PEEP) = 1 cm H2O without recruitment maneuvers (RMs) (low VT/low PEEP/RM−), mimicking the low-VT/low-PEEP strategy of PROVHILO; (2) VT = 7 mL/kg and PEEP = 3 cm H2O with RMs before laparotomy and hourly thereafter (low VT/moderate PEEP/4 RM+), mimicking the protective ventilation strategy of IMPROVE; (3) VT = 7 mL/kg and PEEP = 6 cm H2O with RMs only before laparotomy (low VT/high PEEP/1 RM+), mimicking the strategy used after intubation and before extubation in PROVHILO; or (4) VT = 14 mL/kg and PEEP = 1 cm H2O without RMs (high VT/low PEEP/RM−), mimicking conventional ventilation used in IMPROVE. Seven rats were not tracheotomized, operated, or mechanically ventilated, and constituted the healthy nonoperated and nonventilated controls. RESULTS: Low VT/moderate PEEP/4 RM+ and low VT/high PEEP/1 RM+, compared to low VT/low PEEP/RM− and high VT/low PEEP/RM−, resulted in lower &Dgr;PRS (7.1 ± 0.8 and 10.2 ± 2.1 cm H2O vs 13.9 ± 0.9 and 16.9 ± 0.8 cm H2O, respectively; P< .001) and less mechanical power (63 ± 7 and 79 ± 20 J/min vs 110 ± 10 and 120 ± 20 J/min, respectively; P = .007). Low VT/high PEEP/1 RM+ was associated with less alveolar collapse than low VT/low PEEP/RM− (P = .03). E-cadherin expression was higher in low VT/moderate PEEP/4 RM+ than in low VT/low PEEP/RM− (P = .013) or high VT/low PEEP/RM− (P = .014). The extent of alveolar collapse, E-cadherin expression, and tumor necrosis factor-alpha correlated with &Dgr;PRS (r = 0.54 [P = .02], r = −0.48 [P = .05], and r = 0.59 [P = .09], respectively) and mechanical power (r = 0.57 [P = .02], r = −0.54 [P = .02], and r = 0.48 [P = .04], respectively). CONCLUSIONS: In this model of open abdominal surgery based on the mechanical ventilation strategies used in IMPROVE and PROVHILO trials, lower mechanical power and its surrogate &Dgr;PRS were associated with reduced lung damage.
Frontiers in Physiology | 2017
Andre Soluri-Martins; Lillian Moraes; Raquel S. Santos; Cintia L. Santos; Robert Huhle; Vera Luiza Capelozzi; Paolo Pelosi; Pedro L. Silva; Marcelo Gama de Abreu; Patricia R.M. Rocco
Lung ischemia-reperfusion injury remains a major complication after lung transplantation. Variable ventilation (VV) has been shown to improve respiratory function and reduce pulmonary histological damage compared to protective volume-controlled ventilation (VCV) in different models of lung injury induced by endotoxin, surfactant depletion by saline lavage, and hydrochloric acid. However, no study has compared the biological impact of VV vs. VCV in lung ischemia-reperfusion injury, which has a complex pathophysiology different from that of other experimental models. Thirty-six animals were randomly assigned to one of two groups: (1) ischemia-reperfusion (IR), in which the left pulmonary hilum was completely occluded and released after 30 min; and (2) Sham, in which animals underwent the same surgical manipulation but without hilar clamping. Immediately after surgery, the left (IR-injured) and right (contralateral) lungs from 6 animals per group were removed, and served as non-ventilated group (NV) for molecular biology analysis. IR and Sham groups were further randomized to one of two ventilation strategies: VCV (n = 6/group) [tidal volume (VT) = 6 mL/kg, positive end-expiratory pressure (PEEP) = 2 cmH2O, fraction of inspired oxygen (FiO2) = 0.4]; or VV, which was applied on a breath-to-breath basis as a sequence of randomly generated VT values (n = 1200; mean VT = 6 mL/kg), with a 30% coefficient of variation. After 5 min of ventilation and at the end of a 2-h period (Final), respiratory system mechanics and arterial blood gases were measured. At Final, lungs were removed for histological and molecular biology analyses. Respiratory system elastance and alveolar collapse were lower in VCV than VV (mean ± SD, VCV 3.6 ± 1.3 cmH20/ml and 2.0 ± 0.8 cmH20/ml, p = 0.005; median [interquartile range], VCV 20.4% [7.9–33.1] and VV 5.4% [3.1–8.8], p = 0.04, respectively). In left lungs of IR animals, VCV increased the expression of interleukin-6 and intercellular adhesion molecule-1 compared to NV, with no significant differences between VV and NV. Compared to VCV, VV increased the expression of surfactant protein-D, suggesting protection from type II epithelial cell damage. In conclusion, in this experimental lung ischemia-reperfusion model, VV improved respiratory system elastance and reduced lung damage compared to VCV.