Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Robert Srnec is active.

Publication


Featured researches published by Robert Srnec.


BMC Biotechnology | 2008

Allogeneic and autogenous transplantations of MSCs in treatment of the physeal bone bridge in rabbits

Ladislav Plánka; Petr Gál; H. Kecová; Jiri Klima; Jana Hlučilová; Eva Filova; Evzen Amler; Petr Krupa; Leos Kren; Robert Srnec; Lucie Urbanová; Jana Lorenzová; Alois Nečas

BackgroundThe aim of this experimental study on New Zealands white rabbits was to find differences in the results of treating the distal physeal femoral defect by the transplantation of autologous or allogeneic mesenchymal stem cells (MSCs). After the excision of a created bone bridge in the distal physis of the right femur, modified composite scaffold with MSCs was transplanted into the defect. In animal Group A (n = 11) autogenous MSCs were implanted; in animal Group B (n = 15) allogeneic MSCs were implanted. An iatrogenic physeal defect of the left femur of each animal not treated by MSCs transplantation served as control. The rabbits were euthanized four months after the transplantation. The treatment results were evaluated morphometrically (femoral length and valgus deformity measurement) and histologically (character and quality of the new cartilage).ResultsFour months after the transplantation, the right femurs of the animals in Group A were on average longer by 0.50 ± 0.04 cm (p = 0.018) than their left femurs, the right femurs of rabbits in Group B were on average longer by 0.43 ± 0.01 cm (p = 0.028) than their left femurs.4 months after the therapeutic transplantation of MSCs valgus deformity of the distal part of the right femur of animals in Group A was significantly lower (by 4.45 ± 1.86°) than that of their left femur (p = 0.028), in Group B as well (by 3.66 ± 0.95° than that of their left femur p = 0.001). However, no significant difference was found between rabbits with transplanted autogenous MSCs (Group A) and rabbits with transplanted allogeneic MSCs (Group B) either in the femur length (p = 0.495), or in its valgus deformity (p = 0.1597). After the MSCs transplantation the presence of a newly formed hyaline cartilage was demonstrated histologically in all the animals (both groups). The ability of transplanted MSCs to survive in the damaged physis was demonstrated in vivo by magnetic resonance, in vitro by Perls reaction and immunofluorescence.ConclusionThe transplantation of both autogenous and allogeneic MSCs into a defect of the growth plate appears as an effective method of surgical treatment of physeal cartilage injury. However, the Findings point to the conclusion that there is no clear difference in the final effect of the transplantation procedure used.


Veterinary Surgery | 2011

Quantification of Humeroulnar Incongruity in Labrador Retrievers with and without Medial Coronoid Disease

Pavel Proks; Alois Nečas; Ladislav Stehlík; Robert Srnec; Dominique J. Griffon

OBJECTIVE To quantify humeroulnar incongruity on elbow radiographs in Labrador Retrievers with or without medial coronoid disease (MCD). STUDY DESIGN Retrospective study of 92 elbows. SAMPLE POPULATION Radiographic projections of elbow joints from Labrador Retrievers with MCD (n = 42 elbows; 26 dogs) and without MCD (n = 50 elbows; 25 dogs). PROCEDURE The congruity of the humeroulnar joint was measured using an index of subluxation (SI) for each elbow. SI was defined as the distance between the centers of 2 circles drawn along the margins of the incisura trochlearis and the trochlea of humerus on mediolateral digital radiographic projections, normalized by the radius of the circle circumscribing the humeral trochlea. SI was compared between right and left elbows with and without pathology using a Wilcoxon test for paired data, and between normal and abnormal groups with a Wilcoxon test for unpaired data. Mismatch between ulnar curvature and curvature of humeral trochlea and radioulnar incongruency were also noted (Wilcoxon test). The intraobserver repeatability, correlation between SI and radioulnar incongruency, and between SI and mismatch elbow curvature were estimated with a Pearsons correlation coefficient. RESULTS Intraobserver repeatability of SI measurement was high (r = 0.97). Mean ± SD humeroulnar incongruity (SI) was greater in elbows with MCD (18.5 ± 6.6) than in the normal elbows (1.7 ± 2.0, P < 0.001). The difference between the diameters of the curvatures of the ulnar and humeral trochlea was greater in elbows with MCD (12.5 ± 4.4) than in the normal group (10.7 ± 4.1, P < 0.05). A moderate correlation was found between the degree of humeroulnar incongruity and a radioulnar step (r = 0.63); however, no correlation was identified between SI and the difference between the diameters of the curvatures of the ulnar and humeral trochleae (r = 0.14). CONCLUSION We propose a radiographic index to measure humeroulnar incongruity on mediolateral digital radiographic projections. This index (SI) supports the presence of humeroulnar incongruity in Labrador Retrievers with MCD. Further evaluation of its reproducibility and clinical importance are warranted. Although there is a moderate correlation between humeroulnar incongruity and radioulnar incongruency, causation has not been established.Objective To quantify humeroulnar incongruity on elbow radiographs in Labrador Retrievers with or without medial coronoid disease (MCD). Study Design Retrospective study of 92 elbows. Sample Population Radiographic projections of elbow joints from Labrador Retrievers with MCD (n = 42 elbows; 26 dogs) and without MCD (n = 50 elbows; 25 dogs). Procedure The congruity of the humeroulnar joint was measured using an index of subluxation (SI) for each elbow. SI was defined as the distance between the centers of 2 circles drawn along the margins of the incisura trochlearis and the trochlea of humerus on mediolateral digital radiographic projections, normalized by the radius of the circle circumscribing the humeral trochlea. SI was compared between right and left elbows with and without pathology using a Wilcoxon test for paired data, and between normal and abnormal groups with a Wilcoxon test for unpaired data. Mismatch between ulnar curvature and curvature of humeral trochlea and radioulnar incongruency were also noted (Wilcoxon test). The intraobserver repeatability, correlation between SI and radioulnar incongruency, and between SI and mismatch elbow curvature were estimated with a Pearsons correlation coefficient. Results Intraobserver repeatability of SI measurement was high (r = 0.97). Mean ± SD humeroulnar incongruity (SI) was greater in elbows with MCD (18.5 ± 6.6) than in the normal elbows (1.7 ± 2.0, P < 0.001). The difference between the diameters of the curvatures of the ulnar and humeral trochlea was greater in elbows with MCD (12.5 ± 4.4) than in the normal group (10.7 ± 4.1, P < 0.05). A moderate correlation was found between the degree of humeroulnar incongruity and a radioulnar step (r = 0.63); however, no correlation was identified between SI and the difference between the diameters of the curvatures of the ulnar and humeral trochleae (r = 0.14). Conclusion We propose a radiographic index to measure humeroulnar incongruity on mediolateral digital radiographic projections. This index (SI) supports the presence of humeroulnar incongruity in Labrador Retrievers with MCD. Further evaluation of its reproducibility and clinical importance are warranted. Although there is a moderate correlation between humeroulnar incongruity and radioulnar incongruency, causation has not been established.


Journal of Veterinary Emergency and Critical Care | 2009

Incidence of seizures associated with iopamidol or iomeprol myelography in dogs with intervertebral disk disease: 161 cases (2000-2002).

L. Lexmaulová; Josef Zatloukal; Pavel Proks; Milan Dvorak; Robert Srnec; Petr Raušer; H. Kecová; Alois Nečas

OBJECTIVE To compare the incidence of seizures in dogs with intervertebral disk disease after iopamidol or iomeprol myelography, and to assess whether the incidence of seizures differed between the 2 agents when severity of neurological deficits, location of cord compression, duration of anesthesia, site of myelogram, volume of contrast, and concentration of contrast were evaluated. DESIGN Retrospective study. SETTING Veterinary teaching hospital. ANIMALS One hundred and sixty-one client-owned dogs with intervertebral disk disease. INTERVENTIONS Subarachnoid injection of contrast medium. MEASUREMENTS AND MAIN RESULTS One hundred and sixty-one dogs with intervertebral disk disease were subjected to myelography using iopamidol (n=74) or iomeprol (n=87). Cranial myelography was performed in 31 dogs, caudal myelography in 125 and both cranial and caudal myelography in 5. Seizures occurred in 23 of 161 (14%) dogs. There was no significant difference overall between iopamidol and iomeprol myelography. However, in dogs with thoracolumbar disk extrusion and paraplegia, seizures occurred more frequently after caudal myelography using iopamidol compared with iomeprol. CONCLUSIONS Both iomeprol and iopamidol are suitable for myelography in dogs. Iomeprol is recommended for caudal myelography in paraplegic dogs with thoracolumbar disk extrusion due to the higher incidence of seizures in this group when iopamidol was used.


Biomedical papers of the Medical Faculty of the University Palacký, Olomouc, Czechoslovakia | 2012

Nanotechnology and mesenchymal stem cells with chondrocytes in prevention of partial growth plate arrest in pigs

Ladislav Plánka; Robert Srnec; Petr Raušer; David Stary; Eva Filova; J. Jancar; Jana Juhasova; Leos Kren; Alois Nečas; Petr Gál

INTRODUCTION This study describes the results achieved using a combination of allogeneic mesenchymal stem cells (MSCs) with chondrocytes (CHC) and a new scaffold consisting of type-I collagen and chitosan nanofibers in the prevention of partial growth plate arrest after iatrogenic injury in pigs. MATERIAL AND METHODS The miniature pig was selected as an experimental model to compare the results in the left femoral bones (MSCs and CHC in scaffold transplantation into the iatrogenic partial distal growth plate defect) and right femoral bones (scaffold alone transplantation). The experimental group consisted of 10 animals. Bone marrow from os ilium as the source of MSCs was used. A porous cylinder consisting of 0.5% by weight type-I collagen and 30% by weight chitosan, was the optimal choice. The length of the bone and angular deformity of distal femur after the healing period was measured and the quality and structure of the newly formed cartilage was histologically examined. RESULTS Transplantation of the composite scaffold in combination with MSCs and chondrocytes led to the prevention of growth disorder and angular deformity in the distal epiphysis of the left femur. Compared to the right (control) femur, tissue similar to hyaline cartilage with signs of columnar organization typical of the growth plate occurred in most cases. CONCLUSIONS The promising results of this study reveal the new and effective means for the prevention of bone bridge formation after growth plate injury.


Acta Veterinaria Brno | 2010

Comparison of the Resistance to Bending Forces of the 4.5 LCP Plate-rod Construct and of 4.5 LCP Alone Applied to Segmental Femoral Defects in Miniature Pigs

Lucie Urbanová; Robert Srnec; Pavel Proks; Ladislav Stehlík; Zdeněk Florian; Tomáš Návrat; Alois Nečas

The study deals with the determination of mechanical properties, namely resistance to bending forces, of flexible buttress osteosynthesis using two different bone-implant constructs stabilizing experimental segmental femoral bone defects (segmental ostectomy) in a miniature pig ex vivo model using 4.5 mm titanium LCP and a 3 mm intramedullary pin (“plate and rod” construct) (PR-LCP), versus the 4.5 mm titanium LCP alone (A-LCP). The “plate and rod” fixation (PR-LCP) of the segmental femoral defect is significantly more resistant ( p < 0.05) to bending forces (200 N, 300 N, and 500 N) than LCP alone (A-LCP). Stabilisation of experimental segmental lesions of the femoral diaphysis in miniature pigs by flexible bridging osteosynthesis 4.5 mm LCP in combination with the “plate and rod” construct appears to be a suitable fixation of non-reducible fractures where considerable strain of the implants by bending forces can be assumed. These findings will be used in upcoming in vivo experiments in the miniature pig to investigate bone defect healing after transplantation of mesenchymal stem cells in combination with biocompatible scaffolds. Fracture fixation, comminuted fracture, ostectomy, buttress osteosynthesis, implant failure


Veterinary Surgery | 2011

Quantification of Humeroulnar Incongruity in Labrador Retrievers with and without Medial Coronoid Disease: Quantification of Humeroulnar Incongruity in Labrador Retrievers

Pavel Proks; Alois Nečas; Ladislav Stehlík; Robert Srnec; Dominique J. Griffon

OBJECTIVE To quantify humeroulnar incongruity on elbow radiographs in Labrador Retrievers with or without medial coronoid disease (MCD). STUDY DESIGN Retrospective study of 92 elbows. SAMPLE POPULATION Radiographic projections of elbow joints from Labrador Retrievers with MCD (n = 42 elbows; 26 dogs) and without MCD (n = 50 elbows; 25 dogs). PROCEDURE The congruity of the humeroulnar joint was measured using an index of subluxation (SI) for each elbow. SI was defined as the distance between the centers of 2 circles drawn along the margins of the incisura trochlearis and the trochlea of humerus on mediolateral digital radiographic projections, normalized by the radius of the circle circumscribing the humeral trochlea. SI was compared between right and left elbows with and without pathology using a Wilcoxon test for paired data, and between normal and abnormal groups with a Wilcoxon test for unpaired data. Mismatch between ulnar curvature and curvature of humeral trochlea and radioulnar incongruency were also noted (Wilcoxon test). The intraobserver repeatability, correlation between SI and radioulnar incongruency, and between SI and mismatch elbow curvature were estimated with a Pearsons correlation coefficient. RESULTS Intraobserver repeatability of SI measurement was high (r = 0.97). Mean ± SD humeroulnar incongruity (SI) was greater in elbows with MCD (18.5 ± 6.6) than in the normal elbows (1.7 ± 2.0, P < 0.001). The difference between the diameters of the curvatures of the ulnar and humeral trochlea was greater in elbows with MCD (12.5 ± 4.4) than in the normal group (10.7 ± 4.1, P < 0.05). A moderate correlation was found between the degree of humeroulnar incongruity and a radioulnar step (r = 0.63); however, no correlation was identified between SI and the difference between the diameters of the curvatures of the ulnar and humeral trochleae (r = 0.14). CONCLUSION We propose a radiographic index to measure humeroulnar incongruity on mediolateral digital radiographic projections. This index (SI) supports the presence of humeroulnar incongruity in Labrador Retrievers with MCD. Further evaluation of its reproducibility and clinical importance are warranted. Although there is a moderate correlation between humeroulnar incongruity and radioulnar incongruency, causation has not been established.Objective To quantify humeroulnar incongruity on elbow radiographs in Labrador Retrievers with or without medial coronoid disease (MCD). Study Design Retrospective study of 92 elbows. Sample Population Radiographic projections of elbow joints from Labrador Retrievers with MCD (n = 42 elbows; 26 dogs) and without MCD (n = 50 elbows; 25 dogs). Procedure The congruity of the humeroulnar joint was measured using an index of subluxation (SI) for each elbow. SI was defined as the distance between the centers of 2 circles drawn along the margins of the incisura trochlearis and the trochlea of humerus on mediolateral digital radiographic projections, normalized by the radius of the circle circumscribing the humeral trochlea. SI was compared between right and left elbows with and without pathology using a Wilcoxon test for paired data, and between normal and abnormal groups with a Wilcoxon test for unpaired data. Mismatch between ulnar curvature and curvature of humeral trochlea and radioulnar incongruency were also noted (Wilcoxon test). The intraobserver repeatability, correlation between SI and radioulnar incongruency, and between SI and mismatch elbow curvature were estimated with a Pearsons correlation coefficient. Results Intraobserver repeatability of SI measurement was high (r = 0.97). Mean ± SD humeroulnar incongruity (SI) was greater in elbows with MCD (18.5 ± 6.6) than in the normal elbows (1.7 ± 2.0, P < 0.001). The difference between the diameters of the curvatures of the ulnar and humeral trochlea was greater in elbows with MCD (12.5 ± 4.4) than in the normal group (10.7 ± 4.1, P < 0.05). A moderate correlation was found between the degree of humeroulnar incongruity and a radioulnar step (r = 0.63); however, no correlation was identified between SI and the difference between the diameters of the curvatures of the ulnar and humeral trochleae (r = 0.14). Conclusion We propose a radiographic index to measure humeroulnar incongruity on mediolateral digital radiographic projections. This index (SI) supports the presence of humeroulnar incongruity in Labrador Retrievers with MCD. Further evaluation of its reproducibility and clinical importance are warranted. Although there is a moderate correlation between humeroulnar incongruity and radioulnar incongruency, causation has not been established.


Physiological Research | 2010

Quality of Newly Formed Cartilaginous Tissue in Defects of Articular Surface after Transplantation of Mesenchymal Stem Cells in a Composite Scaffold Based on Collagen I with Chitosan Micro- and Nanofibres

Alois Nečas; Ladislav Plánka; Robert Srnec; Michal Crha; Jana Hlučilová; Jiří Klíma; David Starý; Leoš Křen; Evžen Amler; Lucy Vojtová; Josef Jančář; Petr Gál


Acta Veterinaria Brno | 2009

Mesenchymal Stem Cells in Bone Tissue Regeneration and Application to Bone Healing

Michal Crha; Alois Nečas; Robert Srnec; Jan Janovec; Ladislav Stehlík; Petr Raušer; Lucie Urbanová; Ladislav Plánka; Josef Jančář; Evžen Amler


Physiological Research | 2007

Use of 3D Geometry Modeling of Osteochondrosis-like Iatrogenic Lesions as a Template for Press-and-Fit Scaffold Seeded with Mesenchymal Stem Cells

Petr Krupa; Krsek P; Javorník M; Dostál O; Robert Srnec; Usvald D; Pavel Proks; H. Kecová; Evzen Amler; J. Jancar; Petr Gál; Ladislav Plánka; Alois Nečas


Acta Veterinaria Brno | 2008

Biomaterials and Stem Cells in the Treatment of Articular Cartilage, Meniscal, Physeal, Bone, Ligamentous and Tendineous Defects

Alois Nečas; Ladislav Plánka; Robert Srnec; Petr Raušer; Lucie Urbanová; Jana Lorenzová; Michal Crha; Josef Jančář; Petr Gál

Collaboration


Dive into the Robert Srnec's collaboration.

Top Co-Authors

Avatar

Alois Nečas

University of Veterinary and Pharmaceutical Sciences Brno

View shared research outputs
Top Co-Authors

Avatar

Pavel Proks

University of Veterinary and Pharmaceutical Sciences Brno

View shared research outputs
Top Co-Authors

Avatar

Lucie Urbanová

University of Veterinary and Pharmaceutical Sciences Brno

View shared research outputs
Top Co-Authors

Avatar

Michal Crha

University of Veterinary and Pharmaceutical Sciences Brno

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Petr Raušer

University of Veterinary and Pharmaceutical Sciences Brno

View shared research outputs
Top Co-Authors

Avatar

Josef Jančář

Brno University of Technology

View shared research outputs
Top Co-Authors

Avatar

Ladislav Stehlík

University of Veterinary and Pharmaceutical Sciences Brno

View shared research outputs
Top Co-Authors

Avatar

Evžen Amler

Czech Technical University in Prague

View shared research outputs
Top Co-Authors

Avatar

Lucy Vojtová

Central European Institute of Technology

View shared research outputs
Researchain Logo
Decentralizing Knowledge