Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Robin Shandas is active.

Publication


Featured researches published by Robin Shandas.


Journal of Controlled Release | 2013

Paclitaxel-liposome–microbubble complexes as ultrasound-triggered therapeutic drug delivery carriers

Fei Yan; Lu Li; Zhiting Deng; Qiaofeng Jin; J. L. Chen; Wei Yang; Chih-Kuang Yeh; Junru Wu; Robin Shandas; Xin Liu

Liposome-microbubble complexes (LMC) have become a promising therapeutic carrier for ultrasound-triggered drug delivery to treat malignant tumors. However, the efficacy for ultrasound-assisted chemotherapy in vivo and the underlying mechanisms remain to be elucidated. Here, we investigated the feasibility of using paclitaxel-liposome-microbubble complexes (PLMC) as possible ultrasound (US)-triggered targeted chemotherapy against breast cancer. PTX-liposomes (PL) were conjugated to the microbubble (MB) surface through biotin-avidin linkage, increasing the drug-loading efficiency of MBs. The significant increased release of payloads from liposome-microbubble complexes was achieved upon US exposure. We used fluorescent quantum dots (QDs) as a model drug to show that released QDs were taken up by 4T1 breast cancer cells treated with QD-liposome-microbubble complexes (QLMC) and US, and uptake depended on the exposure time and intensity of insonication. We found that PLMC plus US inhibited tumor growth more effectively than PL plus US or PLMC without US, not only in vitro, but also in vivo. Histologically, the inhibition of tumor growth appeared to result from increased apoptosis and reduced angiogenesis in tumor xenografts. In addition, a significant increase of drug concentration in tumors was observed in comparison to treatment with non-conjugated PL or PLMC without US. The significant increase in an antitumor efficacy of PLMC plus US suggests their potential use as a new targeted US chemotherapeutic approach to inhibit breast cancer growth.


Journal of Vascular Research | 2009

Effects of Pathological Flow on Pulmonary Artery Endothelial Production of Vasoactive Mediators and Growth Factors

Min Li; Kurt R. Stenmark; Robin Shandas; Wei Tan

Background: Alterations in pulmonary blood flow are often associated with the initiation and progression of pulmonary vascular disease. However, the cellular mechanisms involved in mediating flow effects in the pulmonary circulation remain unclear. Depending on the disease condition, flow may be extremely low or high. We therefore examined effects of pathologically low and high flow on endothelial production of factors capable of affecting pulmonary vascular tone and structure as well as on potential underlying mechanisms. Methods: Flow effects on pulmonary endothelial release of NO, PGF1a, ET-1 and TxB2, on expression of total and phosphorylated eNOS as well as Akt, and on VEGF were examined. Additionally, in a coculture system, effects of flow-exposed endothelial cells on smooth muscle (SM) proliferation and contractile protein were studied. Results: Compared to physiological flow, pathologically high and low flow attenuated endothelial release of NO and PGF1a, and enhanced release of ET-1. Physiological flow activated the Akt/eNOS pathway, while pathological flow depressed it. Pathologically high flow altered VE-cadherin expression. Pathologically high flow on the endothelium upregulated α-SM-actin and SM-MHC without affecting SM proliferation. Conclusion: Physiological flow leads to production of mediators which favor vasodilation. Pathological flow alters the balance of mediator production which favors vasoconstriction.


Comprehensive Physiology | 2012

Mechanics and Function of the Pulmonary Vasculature: Implications for Pulmonary Vascular Disease and Right Ventricular Function

Steven R. Lammers; Devon Scott; Kendall S. Hunter; Wei Tan; Robin Shandas; Kurt R. Stenmark

he relationship between cardiac function and the afterload against which the heart muscle must work to circulate blood throughout the pulmonary circulation is defined by a complex interaction between many coupled system parameters. These parameters range broadly and incorporate system effects originating primarily from three distinct locations: input power from the heart, hydraulic impedance from the large conduit pulmonary arteries, and hydraulic resistance from the more distal microcirculation. These organ systems are not independent, but rather, form a coupled system in which a change to any individual parameter affects all other system parameters. The result is a highly nonlinear system which requires not only detailed study of each specific component and the effect of disease on their specific function, but also requires study of the interconnected relationship between the microcirculation, the conduit arteries, and the heart in response to age and disease. Here, we investigate systems-level changes associated with pulmonary hypertensive disease progression in an effort to better understand this coupled relationship.


American Journal of Physiology-lung Cellular and Molecular Physiology | 2013

High pulsatility flow stimulates smooth muscle cell hypertrophy and contractile protein expression.

Devon Scott; Yan Tan; Robin Shandas; Kurt R. Stenmark; Wei Tan

Proximal arterial stiffening is an important predictor of events in systemic and pulmonary hypertension, partly through its contribution to downstream vascular abnormalities. However, much remains undetermined regarding the mechanisms involved in the vascular changes induced by arterial stiffening. We therefore addressed the hypothesis that high pulsatility flow, caused by proximal arterial stiffening, induces downstream pulmonary artery endothelial cell (EC) dysfunction that in turn leads to phenotypic change of smooth muscle cells (SMCs). To test the hypothesis, we employed a model pulmonary circulation in which upstream compliance regulates the pulsatility of flow waves imposed onto a downstream vascular mimetic coculture composed of pulmonary ECs and SMCs. The effects of high pulsatility flow on SMCs were determined both in the presence and absence of ECs. In the presence of ECs, high pulsatility flow increased SMC size and expression of the contractile proteins, smooth muscle α-actin (SMA) and smooth muscle myosin heavy chain (SM-MHC), without affecting proliferation. In the absence of ECs, high pulsatility flow decreased SMC expression of SMA and SM-MHC, without affecting SMC size or proliferation. To identify the molecular signals involved in the EC-mediated SMC responses, mRNA and/or protein expression of vasoconstrictors [angiotensin-converting enzyme (ACE) and endothelin (ET)-1], vasodilator (eNOS), and growth factor (TGF-β1) in EC were examined. Results showed high pulsatility flow decreased eNOS and increased ACE, ET-1, and TGF-β1 expression. ACE inhibition with ramiprilat, ET-1 receptor inhibition with bosentan, and treatment with the vasodilator bradykinin prevented flow-induced, EC-dependent SMC changes. In conclusion, high pulsatility flow stimulated SMC hypertrophy and contractile protein expression by altering EC production of vasoactive mediators and cytokines, supporting the idea of a coupling between proximal vascular stiffening, flow pulsatility, and downstream vascular function.


Comprehensive Physiology | 2011

Pulmonary Vascular Stiffness: Measurement, Modeling, and Implications in Normal and Hypertensive Pulmonary Circulations

Kendall S. Hunter; Steven R. Lammers; Robin Shandas

This article introduces the concept of pulmonary vascular stiffness, discusses its increasingly recognized importance as a diagnostic marker in the evaluation of pulmonary vascular disease, and describes methods to measure and model it clinically, experimentally, and computationally. It begins with a description of systems-level methods to evaluate pulmonary vascular compliance and recent clinical efforts in applying such techniques to better predict patient outcomes in pulmonary arterial hypertension. It then progresses from the systems-level to the local level, discusses proposed methods by which upstream pulmonary vessels increase in stiffness, introduces concepts around vascular mechanics, and concludes by describing recent work incorporating advanced numerical methods to more thoroughly evaluate changes in local mechanical properties of pulmonary arteries.


Computer Methods and Programs in Biomedicine | 2012

Impact of pulmonary vascular stiffness and vasodilator treatment in pediatric pulmonary hypertension: 21 patient-specific fluid-structure interaction studies

Zhenbi Su; Kendall S. Hunter; Robin Shandas

Recent clinical studies of pulmonary arterial hypertension (PAH) have found correlations between increased pulmonary vascular stiffness (PVS) and poorer disease outcomes. However, mechanistic questions remain about the relationships amongst PVS, RV power, and vascular hemodynamics in the setting of progressive PAH that are difficult or impossible to answer using direct measurements. Clinically validated patient-specific computational modeling may allow exploration of these issues through perturbation-based predictive testing. Here we use a simple patient-specific model to answer four questions: how do hemodynamics change as PAH worsens? How does increasing PVS impact hemodynamics and RV power? For a patient with moderate PAH, what are the consequences if the pressures increase modestly yet sufficiently to engage collagen in those vessels? What impact does pressure-reducing vasodilator treatment have on hemodynamics? Twenty-one sets of model-predicted impedance and mean PA pressure (mPAP) show good agreement with clinical measurements, thereby validating the model. Worsening was modeled using data from three PAH outcomes groups; these show not only the expected increase in mPAP, but also an increase in pressure pulsatility. Interestingly, chronically increasing mPAP decreased WSS, suggesting that increased PA cross-sectional area affected WSS greater than increased PVS. For a patient with moderately high PVR (12.7 WU) with elastin-based upstream vascular remodeling, moving from elastin-dominant vessel behavior to collagen-dominant behavior caused substantial increases in mPAP, pressure and WSS pulsatility. For the same patient, reducing PVR through a simulated vasodilator to a value equivalent to mild PAH did not decrease pressure pulsatility and dramatically increased WSS pulsatility. Overall, these results suggest a close association between PVS and hemodynamics and that hemodynamics may play an important role in progressing PAH. These support the hypothesis that treatments should target decreasing or reversing upstream vascular remodeling in addition to decreasing mean pressures.


Biomacromolecules | 2016

Biomimetic Polymers for Cardiac Tissue Engineering.

Brisa Peña; Valentina Martinelli; Mark Y. Jeong; Susanna Bosi; Romano Lapasin; Matthew R.G. Taylor; Carlin S. Long; Robin Shandas; Daewon Park; Luisa Mestroni

Heart failure is a morbid disorder characterized by progressive cardiomyocyte (CM) dysfunction and death. Interest in cell-based therapies is growing, but sustainability of injected CMs remains a challenge. To mitigate this, we developed an injectable biomimetic Reverse Thermal Gel (RTG) specifically engineered to support long-term CM survival. This RTG biopolymer provided a solution-based delivery vehicle of CMs, which transitioned to a gel-based matrix shortly after reaching body temperature. In this study we tested the suitability of this biopolymer to sustain CM viability. The RTG was biomolecule-functionalized with poly-l-lysine or laminin. Neonatal rat ventricular myocytes (NRVM) and adult rat ventricular myocytes (ARVM) were cultured in plain-RTG and biomolecule-functionalized-RTG both under 3-dimensional (3D) conditions. Traditional 2D biomolecule-coated dishes were used as controls. We found that the RTG-lysine stimulated NRVM to spread and form heart-like functional syncytia. Regarding cell contraction, in both RTG and RTG-lysine, beating cells were recorded after 21 days. Additionally, more than 50% (p value < 0.05; n = 5) viable ARVMs, characterized by a well-defined cardiac phenotype represented by sarcomeric cross-striations, were found in the RTG-laminin after 8 days. These results exhibit the tremendous potential of a minimally invasive CM transplantation through our designed RTG-cell therapy platform.


Journal of Biomedical Materials Research Part A | 2015

A heparin-mimicking reverse thermal gel for controlled delivery of positively charged proteins

Brisa Peña; Robin Shandas; Daewon Park

Positively charged therapeutic proteins have been used extensively for biomedical applications. However, the safety and efficacy of proteins are mostly limited by their physical and chemical instability and short half-lives in physiological conditions. To this end, we created a heparin-mimicking sulfonated reverse thermal gel as a novel protein delivery system by sulfonation of a graft copolymer, poly(serinol hexamethylene urea)-co-poly(N-isopropylacylamide), or PSHU-NIPAAm. The net charge of the sulfonated PSHU-NIPAAm was negative due to the presence of sulfonate groups. The sulfonated PSHU-NIPAAm showed a typical temperature-dependent sol-gel phase transition, where polymer solutions turned to a physical gel at around 32°C and maintained gel status at body temperature. Both in vitro cytotoxicity tests using C2C12 myoblast cells and in vivo cytotoxicity tests by subcutaneous injections demonstrated excellent biocompatibility. In vitro release tests using bovine serum albumin revealed that the release from the sulfonated PSHU-NIPAAm was more sustained than that from the plain PSHU-NIPAAm. Furthermore, this sulfonated PSHU-NIPAAm system did not affect protein structure after 70-day observation periods.


Journal of Biomedical Materials Research Part B | 2014

Biocompatibility and tissue integration of a novel shape memory surgical mesh for ventral hernia: In vivo animal studies

Michael M. Zimkowski; Mark E. Rentschler; Jonathan A. Schoen; Nageswara Mandava; Robin Shandas

Approximately 400,000 ventral hernia repair surgeries are performed each year in the United States. Many of these procedures are performed using laparoscopic minimally invasive techniques and employ the use of surgical mesh. The use of surgical mesh has been shown to reduce recurrence rates compared to standard suture repairs. The placement of surgical mesh in a ventral hernia repair procedure can be challenging, and may even complicate the procedure. Others have attempted to provide commercial solutions to the problems of mesh placement, but these have not been well accepted by the clinical community. In this article, two versions of shape memory polymer (SMP)-modified surgical mesh, and unmodified surgical mesh, were compared by performing laparoscopic manipulation in an acute porcine model. Also, SMP-integrated polyester surgical meshes were implanted in four rats for 30-33 days to evaluate chronic biocompatibility and capacity for tissue integration. Porcine results show that the modified mesh provides a controlled, temperature-activated, automated deployment when compared to an unmodified mesh. In rats, results indicate that implanted SMP-modified meshes exhibit exceptional biocompatibility and excellent integration with surrounding tissue with no noticeable differences from the unmodified counterpart. This article provides further evidence that an SMP-modified surgical mesh promises reduction in surgical placement time and that such a mesh is not substantially different from unmodified meshes in chronic biocompatibility.


Journal of Biomedical Materials Research Part A | 2013

Integrating a novel shape memory polymer into surgical meshes decreases placement time in laparoscopic surgery: An in vitro and acute in vivo study

Michael M. Zimkowski; Mark E. Rentschler; Jonathan A. Schoen; Bryan Rech; Nageswara Mandava; Robin Shandas

About 600,000 hernia repair surgeries are performed each year; recently, the use of laparoscopic minimally invasive techniques has become increasingly popular in these operations. Use of surgical mesh in hernia repair has shown lower recurrence rates compared to other repair methods. However in many procedures, placement of surgical mesh can be challenging and even complicate the procedure, potentially leading to lengthy operating times. Various techniques have been attempted to improve mesh placement, including use of specialized systems to orient the mesh into a specific shape, with limited success and acceptance. In this study, a programmed novel Shape Memory Polymer (SMP) was integrated into commercially available polyester surgical meshes to add automatic unrolling and tissue conforming functionalities, while preserving the intrinsic structural properties of the original surgical mesh. Tensile testing and Dynamic Mechanical Analysis was performed on four different SMP formulas to identify appropriate mechanical properties for surgical mesh integration. In vitro testing involved monitoring the time required for a modified surgical mesh to deploy in a 37°C water bath. An acute porcine model was used to test the in vivo unrolling of SMP integrated surgical meshes. The SMP-integrated surgical meshes produced an automated, temperature activated, controlled deployment of surgical mesh on the order of several seconds, via laparoscopy in the animal model. Results indicate surgical mesh modified with SMP is capable of laparoscopic deployment in vivo, activated by body temperature. This suggests a reduction in surgical operating time and improved mesh placement characteristics is possible with SMP-integrated surgical meshes.

Collaboration


Dive into the Robin Shandas's collaboration.

Top Co-Authors

Avatar

Kendall S. Hunter

University of Colorado Denver

View shared research outputs
Top Co-Authors

Avatar

Daewon Park

University of Colorado Denver

View shared research outputs
Top Co-Authors

Avatar

Bryan Rech

University of Colorado Boulder

View shared research outputs
Top Co-Authors

Avatar

Malik Y. Kahook

University of Colorado Denver

View shared research outputs
Top Co-Authors

Avatar

Naresh Mandava

University of Colorado Denver

View shared research outputs
Top Co-Authors

Avatar

Carlin S. Long

University of Colorado Denver

View shared research outputs
Top Co-Authors

Avatar

Craig Lanning

University of Colorado Hospital

View shared research outputs
Top Co-Authors

Avatar

D. Dunbar Ivy

University of Colorado Denver

View shared research outputs
Top Co-Authors

Avatar

Devatha P. Nair

University of Colorado Boulder

View shared research outputs
Top Co-Authors

Avatar

Kurt R. Stenmark

University of Colorado Denver

View shared research outputs
Researchain Logo
Decentralizing Knowledge