Rodrigo Borges Fonseca
State University of Campinas
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Rodrigo Borges Fonseca.
Brazilian Oral Research | 2005
Carlos José Soares; Eliane Cristina Gava Pizi; Rodrigo Borges Fonseca; Luis Roberto Marcondes Martins
The aim of this study was to evaluate the influence of the embedment material and periodontal ligament simulation on fracture resistance of bovine teeth. Eighty bovine incisor teeth were randomized into 8 groups (n = 10), embedded in acrylic or polystyrene resin using 4 types of periodontal ligament simulation: 1--absence of the ligament; 2--polyether impression material; 3--polysulfide impression material; 4--polyurethane elastomeric material. The specimens were stored at 370C and 100% humidity for 24 hours. Specimens were submitted to tangential load on the palatal surface at 0.5 mm/minute crosshead speed until fracture. The fracture modes were analyzed as follows: 1--coronal fracture; 2--cemento-enamel junction fracture; 3--partial root fracture; 4--total root fracture. Statistical analyses by two-way ANOVA and Tukeys test were applied (p < 0.05). The results showed that root embedment method and periodontal ligament simulation have a significant effect on fracture resistance. Artificial periodontal ligament modified the fracture modes.
Archives of Oral Biology | 2008
Rodrigo Borges Fonseca; Francisco Haiter-Neto; H.L. Carlo; Carlos José Soares; Mário Alexandre Coelho Sinhoreti; Regina Maria Puppin-Rontani; Lourenço Correr-Sobrinho
Studies have evaluated dental hard tissues characteristics from animal species in order to be used as a substitute for human teeth. The aim of this study was to evaluate the radiodensity and hardness of human and bovine enamel and dentin, varying bovine teeth age. Five specimens (1mm thick) were obtained from animals aged 20 (B20), 30 (B30), 38 (B38) and 48 (B48)months and from 20 to 30-years-old human third molars (H). The radiographic images were taken with a phosphor plaque digital system (Digora Optime). The radiodensity was obtained and Knoop hardness (KHN) was recorded (100g for 15s--5 indentations per specimen). Data were analyzed by one-way ANOVA following Tukeys HSD test and Dunnets two-sided t-test. Radiodensity was similar within enamel groups, but bovine dentin presented higher radiodensity than human one regardless of age groups. Enamel-KHN showed differences between B20-B30 and B38-B48-H, and dentin-KHN was similar within all groups. Enamel was always more radiodense than dentin and also presented higher KHN (p=0.001). The use of bovine enamel or dentin should take into consideration the teeth age, but as a general rule it should be recommended to select older bovine teeth due to better chances to find greater similarity with human teeth.
Clinical Oral Investigations | 2006
Rodrigo Borges Fonseca; Carolina Assaf Branco; Paulo Vinícius Soares; Lourenço Correr-Sobrinho; Francisco Haiter-Neto; Alfredo Júlio Fernandes-Neto; Carlos José Soares
The aim of this study was to determine the radiodensity of base, liner and luting dental materials and to compare them with human enamel and dentin. Four classes of materials were examined: conventional glass ionomers (CG)—Vitro Cem, Ketac Bond, Vidrion F, Vidrion C; resin-modified glass ionomers (RMGI)—Fuji II LC, Vitrebond; resinous cement (RC)—Rely-X ARC; and zinc phosphate cement (ZP)—Cimento LS. Five 2-mm-thick standard samples of each material and five 2-mm-thick enamel and dentin samples were produced. An aluminum step wedge served as control. Samples were positioned over a phosphor plate of Digora digital system, exposed to X-ray, and the radiodensity obtained in the software Digora for Windows 2.0. Data were submitted to Kruskal–Wallis and Dunnett multiple comparisons test (α=0.05). According to statistical analysis, the following sequence in degree of radiodensity could be seen among the groups: Cimento LS (ZP) > Vitro Cem (CG) = Fuji II LC (RMGI) = Rely-X ARC (RC) = Vitrebond (RMGI) > Ketac Bond (CG) > enamel = Vidrion F (CG) > Vidrion C (CG) = dentin. The presence of radiopaque fillers such as zinc, strontium, zirconium, barium, and lanthanium rather than material type seems to be the most important factor when analyzing material radiodensity. Almost all investigated materials presented an accepted radiodensity.
Brazilian Oral Research | 2005
Carlos José Soares; Leonardo Celiberto; Paula Dechichi; Rodrigo Borges Fonseca; Luis Roberto Marcondes Martins
The aim of this study was to evaluate the microleakage of direct and indirect composite inlays by stereomicroscopy and scanning electron microscopy (SEM). Thirty bovine incisors were ground to obtain an incisal platform, simulating the occlusal surface of a human molar. Each tooth received two 8 degrees proximal cavities with cervical finishing line prepared in dentine or enamel. One of the cavities was filled with Filtek Z250/Single Bond, using the direct technique, and the other was filled with with Solidex/Rely X ARC/Single Bond, using the indirect technique. The samples were stored in water at 37 degrees C for 24 hours and placed in a 50% silver nitrate solution for 6 hours in a dark container. Next, the samples were washed under running water, immersed in a developing solution and exposed to fluorescent light for 12 hours. The teeth were then severed and evaluated for dye penetration by stereomicroscopy and SEM. There were no significant differences between the direct and indirect techniques for the cervical finishing line in enamel, but for the finishing line in dentin, the indirect technique allowed less microleakage than the direct technique. SEM analysis showed leakage similar to that observed by stereomicroscopic analysis. The use of stereomicroscopic and SEM evaluations improves microleakage analysis.
Brazilian Oral Research | 2008
Carlos José Soares; Rodrigo Borges Fonseca; Henner Alberto Gomide; Lourenço Correr-Sobrinho
Several in vitro studies employ the confection of cavity preparations that are difficult to standardize by means of manual high speed handpieces. This study presents the development of a cavity preparation machine designed to standardize in vitro cavity preparations. A metal base of 25 mm x 25 mm x 4 mm (length x width x height) was coupled to a small mobile table which was designed to be able to move by means of two precision micrometers (0.01-mm accuracy) in the horizontal directions (right-left, and back-front). A high speed handpiece was coupled to a metallic connecting rod which had an accurate dial indicator enabling control of the vertical movement. The high speed handpiece is also able to move 180 degrees around its longitudinal axis and 360 degrees around its transversal axis. The suggested cavity preparation machine precisely helps in the standardization of cavity preparations for in vitro studies.
Clinical Oral Investigations | 2007
Carlos José Soares; Fernanda Ribeiro Santana; Rodrigo Borges Fonseca; Luis Roberto Marcondes Martins; Francisco Haiter Neto
The purpose of this study was to evaluate the radiodensity of indirect restorative systems and to determine its influence on detection of resin cement overhangs. Sixty sound molars with similar dimensions were selected, and MOD inlay preparations were made in a standardized fashion with 6° taper of the walls. Restorations were made with a porcelain, Duceram LFC, and with three indirect composites, Solidex, Artglass, and Targis. Digital radiographic images were taken before and after cementation of the inlays (Digora system) and were analyzed on two regions, the cervical and the isthmus floor. Digital radiodensity measurements were performed on standardized points symmetrically distributed over each restoration and tooth structure. Cement overhangs were detected through visual analysis by three evaluators. Data were statistically analyzed utilizing ANOVA following Tukey’s test (p < 0.05), showing that Solidex presented lower radiodensity than Duceram LFC, and both Artglass and Targis presented similar higher levels of radiodensity than the other groups. Radiodensity of cervical regions was always greater than for isthmus floor regions. Detection of the resin cement overhangs is easier observed on Solidex and Duceram LFC. Radiodensity is highly influenced by restorative material type and tooth regions. The detection of radiopaque resin cement overhangs is influenced by radiodensity of restorative materials.
Clinical Oral Investigations | 2008
Rodrigo Borges Fonseca; Lourenço Correr-Sobrinho; Alfredo Júlio Fernandes-Neto; Paulo Sérgio Quagliatto; Carlos José Soares
The aim of this study was to evaluate the influence of different cavity preparation designs on marginal accuracy of laboratory-processed resin composite restored teeth. Eighty mandibular human third molars were selected. There were two experimental factors, occlusal isthmus width (narrow vs wide) and cuspal coverage (inlay, one-cusp onlay, two-cusp onlay, and all-cusp onlay), resulting on eight groups (N = 10). Indirect composite restorations (SR Adoro, Ivoclar-Vivadent) were manufactured and positioned over each respective preparation. Marginal accuracy evaluation was accomplished using a stereomicroscope at three points on buccal, lingual, mesial, and distal regions with 40× magnification. The results showed significant differences (P = 0.00) with wide inlay showing the best overall marginal accuracy and narrow inlay the worst one. Two-way analysis of variance (ANOVA) showed significant differences when considering the factor occlusal isthmus width (P = 0.00). In general, preparations with wide occlusal isthmus presented better results than narrow ones, except for wide all-cusp onlays; however, the test failed to show differences when considering the cuspal coverage (P = 0.42) or the interaction between both factors (P = 0.30). The effect of occlusal width extension on marginal accuracy of indirect composite resin restorations is significant, with lower values of gaps width in wide preparations, but since in a clinical situation this would mean greater removal of sound tooth structure, less-aggressive preparations combined with other restorative procedures seem to be more feasible.
Archives of Oral Biology | 2002
R.F Gerlach; D.B Toledo; Rodrigo Borges Fonseca; Pedro Duarte Novaes; Sergio Roberto Peres Line; José Merzel
Remodelling of the socket surrounding the continuously growing and erupting rat incisor was examined in teeth under normo, hyper and hypofunctional conditions. Cross-sections of the mandible were observed under fluorescence microscopy, where minocycline labelling evidenced bone remodelling. Animals had received minocycline (10 mg/day) during the experimental period. Control animals (from all three groups) received vehicle alone and samples from these animals were not fluorescent. Minocycline did not interfere with the eruption rates in any of the functional conditions studied. Normofunctional (impeded) incisors showed constant osteogenic activity in the alveolar bone facing the periodontal ligament in all regions of the incisor. Under hypofunctional (unimpeded) and hyperfunctional (impeded) conditions, osteogenesis in the region close to the alveolar crest was markedly increased in the mesial wall of the socket. The labial alveolar bone, facing the enamel-related periodontium, was almost entirely formed during the experimental period in all the groups, but in hyper and hypofunctional teeth the newly formed bone was thicker and contained a substantial amount formed before the experimental period. In the more apical regions of the socket no marked differences between the three functional conditions were found. The similar bone remodelling shown in hypo and hyperfunctional teeth might indicate that there are common factors causing this pattern. Consideration of possible factors appear to rule out the eruption rate, which is very different under these two functional conditions.
Journal of Applied Oral Science | 2010
Rodrigo Borges Fonseca; Carolina Assaf Branco; Paulo Sérgio Quagliatto; Luciano de Souza Gonçalves; Carlos José Soares; Hugo Lemes Carlo; Lourenço Correr-Sobrinho
Objective To determine the influence of P/L ratio on the radiodensity and diametral tensile strength (DTS) of glass ionomer cements. Material and Methods There were 2 factors under study: P/L ratio (manufacturers recommended P/L ratio and a 50% reduced P/L ratio), and materials (Vitro Molar, Vitro Fil, Vitro Cem conventional GICs and Vitro Fil LC, Ortho Glass LC RMGICs). Five 1-mm-thick samples of each material-P/L ratio were produced for radiodensity evaluation. Samples were x-ray exposed onto Digora phosphor plate and radiodensity was obtained using the software Digora for Windows 2.5 Rev 0. For DTS, five (4.0x8.0 mm) cylinder samples of each material were tested (0.5 mm/min). Data were subjected to one- and two-way ANOVA (5x2) followed by Tukeys HSD test, or Kruskal-Wallis and Dunns method. For paired comparisons, t-test or Mann-Whitney test were used (a=0.05). Results There was a significant interaction (P=0.001) for the studied factors (materials vs. P/L ratio). Reduced P/L ratio resulted in significantly lower DTS for the RMGICs, but radiodensity was affected for all materials (P<0.05). Conclusions Reduced P/L ratio affected properties of the tested glass ionomer cements. RMGICs were more susceptible to lower values of DTS, but radiodensity decreased for all materials following P/L ratio reduction.
ISRN Biomaterials | 2013
Rodrigo Dalla Lana Mattiello; Túlio Marcos Kalife Coêlho; Elizeu Insaurralde; Alan Augusto Kalife Coelho; Gustavo Adolfo Pereira Terra; Amanda Vessoni Barbosa Kasuya; Isabella Negro Favarão; Luciano de Souza Gonçalves; Rodrigo Borges Fonseca
In spite of high mechanical strength, zirconia-based ceramics (ZrO2) has poor bond strength after conventional bond cementation procedures, requiring different surface treatment methods (STMs). This review gathered information about the STM for adhesive cementation (AC) to ZrO2 in the PubMed database, considering in vitro studies pertaining to AC for acid-resistant ceramics (ZrO2) limited to peer-reviewed papers published in English between 1965 and 2013 in dental journals. Different STMs have been proposed for ZrO2: air-abrasion (laboratory or chairside) with silica- (Si-) coated aluminum particles, the use of materials containing phosphate monomers, primer or silane application, laser irradiation, Si vapor phase deposition, and selective infiltration etching. In conclusion, STMs improve bond strength of resin luting cement to ZrO2 mainly when tested in short time. STMs must be correlated to the type of ZrO2 and the resin cement.