Sandeep Ahuja
Intel
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Sandeep Ahuja.
semiconductor thermal measurement and management symposium | 2011
Nishi Ahuja; Chuck Rego; Sandeep Ahuja; Matt Warner; Akhil Docca
Advances in server technology have resulted in the cost of acquiring server equipment trending down, while economies of scale in data centers have significantly reduced the cost of labor. This leaves the cost of the energy as the next target for optimization. Energy costs are driven by operating the IT equipment, the switchgear that provides uninterrupted power to the equipment, and in cooling the IT equipment. In a typical datacenter, almost 40% of the total power consumption is spent on cooling. In addition, cooling effectiveness is a first order factor in determining the lifespan of the data center. One of the emerging trends in the industry is to move datacenter operations to higher ambient temperatures with some Operators wanting to set supply air temperatures as high as 40°C while improving cooling system efficiency. This study will show that with optimized cooling control one could reduce the total cost of ownership at the datacenter level by optimizing the datacenter cooling budget while ensuring no performance loss at increased ambient temperature conditions. This paper describes a platform-assisted thermal management approach that uses new sensors providing server airflow and server outlet temperature to improve control of the data centers cooling solution. This data is also used as input to a computational fluid dynamics (CFD) model for accurate predictive analysis and optimization of future change scenarios, thus increasing the data center efficiency and reducing power consumption. A key component of the study will be the use of computational fluid dynamics CFD analysis for optimizing the data center cooling system.
semiconductor thermal measurement and management symposium | 2013
Nishi Ahuja; Charles W. Rego; Sandeep Ahuja; Shen Zhou; Saurabh Shrivastava
In a typical data center, a significant portion of the total power consumption is spent on data center cooling. This paper addresses the problem of cooling inefficiency resulting from airflow mismatch between what is required by the IT equipment vs. what is supplied by the facility fans. The paper proposes two new virtual sensors for a server; volumetric airflow and outlet temperature sensor. A method for calculating server volumetric airflow in real time based on fan RPM values is outlined. The calculated volumetric airflow and outlet temperature are exposed to Intel Data center Manager (DCM) using IPMI commands. DCM can then aggregate server airflow to compute airflow demand by rack, row or data center level. The information can be used to control facility fans to improve cooling efficiency of the data center. This represents a significant improvement over use of expensive temperature & pressure sensors distributed throughout the data center to control facility fans.
Archive | 2008
Ioan Sauciuc; Sandeep Ahuja; Ashish Gupta
Archive | 2012
Sandeep Ahuja; Eric W. Buddrius; Roger D. Flynn; Rajat Agarwal
Archive | 2012
Sandeep Ahuja; Robin A. Steinbrecher; Susan F. Smith; David Ayers
Archive | 2010
Robin A. Steinbrecher; Sandeep Ahuja; Casey R. Winkel
Archive | 2007
Sandeep Ahuja; Ioan Sauciuc
Archive | 2007
Ioan Sauciuc; Kazimierz L. Kozyra; Sandeep Ahuja; Gregory M. Chrysler
Archive | 2013
Ankush Varma; Robin A. Steinbrecher; Susan F. Smith; Sandeep Ahuja; Vivek Garg; Tessil Thomas; Krishnakanth V. Sistla; Chris Poirier; Martin Mark T. Rowland
Archive | 2013
Robin A. Steinbrecher; Nishi Ahuja; Sandeep Ahuja