Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Simone Lotti is active.

Publication


Featured researches published by Simone Lotti.


Proceedings of SPIE | 2012

The x-ray microcalorimeter spectrometer onboard Athena

J. W. den Herder; D. Bagnali; Simon R. Bandler; Marco Barbera; X. Barcons; Didier Barret; P. Bastia; M. Bisotti; C. Cara; M. T. Ceballos; Leonardo Corcione; Beatriz Cobo; L. Colasanti; J. de Plaa; M. J. DiPirro; W. B. Doriese; Yuichiro Ezoe; Ryuichi Fujimoto; F. Gatti; L. Gottardi; P. Guttridge; R. den Hartog; I. Hepburn; R. L. Kelley; K. D. Irwin; Yoshitaka Ishisaki; Caroline A. Kilbourne; P.A.J. de Korte; J. van der Kuur; Simone Lotti

One of the instruments on the Advanced Telescope for High-Energy Astrophysics (Athena) which was one of the three missions under study as one of the L-class missions of ESA, is the X-ray Microcalorimeter Spectrometer (XMS). This instrument, which will provide high-spectral resolution images, is based on X-ray micro-calorimeters with Transition Edge Sensor (TES) and absorbers that consist of metal and semi-metal layers and a multiplexed SQUID readout. The array (32 x 32 pixels) provides an energy resolution of < 3 eV. Due to the large collection area of the Athena optics, the XMS instrument must be capable of processing high counting rates, while maintaining the spectral resolution and a low deadtime. In addition, an anti-coincidence detector is required to suppress the particle-induced background. Compared to the requirements for the same instrument on IXO, the performance requirements have been relaxed to fit into the much more restricted boundary conditions of Athena. In this paper we illustrate some of the science achievable with the instrument. We describe the results of design studies for the focal plane assembly and the cooling systems. Also, the system and its required spacecraft resources will be given.


Proceedings of SPIE | 2014

ATHENA end-to-end simulations

J. Wilms; Thorsten Brand; Didier Barret; T. Beuchert; Jan-Willem den Herder; Ingo Kreykenbohm; Simone Lotti; Norbert Meidinger; Kirpal Nandra; Philippe Peille; Luigi Piro; C. Schmid; Randall K. Smith; Christoph Tenzer; M. Wille; R. Willingale

We present an overview of the development of the end-to-end simulation programs for the instruments on the future European X-ray astronomy mission Athena. The overview includes the design considerations behind the simulation software and the current status and planned developments of the simulators for the X-ray Integral Field Unit and the Wide Field Imager.


Astronomy and Astrophysics | 2014

In-orbit background of X-ray microcalorimeters and its effects on observations

Simone Lotti; D. Cea; C. Macculi; T. Mineo; L. Natalucci; E. Perinati; Luigi Piro; M. Federici; B. Martino

Methods.There are no experimental data about the background experienced by microcalorimeters in the L2 orbit, and thus the particle background levels were calculated by means of Monte Carlo simulations: we considered the original design configuration and an improved configuration aimed to reduce the unrejected background, and tested them in the L2 orbit and in the low Earth orbit, comparing the results with experimental data reported by other X-ray this http URL show the results obtainable with the improved configuration we simulated the observation of a faint, high-redshift, point source (F[0.5-10 keV]~6.4E-16 erg cm-2 s-1, z=3.7), and of a hot galaxy cluster at R200 (Sb[0.5-2 keV]=8.61E-16 erg cm-2 s-1 arcmin-2,T=6.6 keV). Results.First we confirm that implementing an active cryogenic anticoincidence reduces the particle background by an order of magnitude and brings it close to the required level.The implementation and test of several design solutions can reduce the particle background level by a further factor of 6 with respect to the original configuration.The best background level achievable in the L2 orbit with the implementation of ad-hoc passive shielding for secondary particles is similar to that measured in the more favorable LEO environment without the passive shielding, allowing us to exploit the advantages of the L2 orbit.We define a reference model for the diffuse background and collect all the available information on its variation with epoch and pointing direction.With this background level the ATHENA mission with the X-IFU instrument is able to detect ~4100 new obscured AGNs with F>6.4E-16 erg cm-2 s-1 during three years, to characterize cluster of galaxies with Sb(0.5-2 keV)>9.4E-16 erg cm-2 s-1 sr-1 on timescales of 50 ks (500 ks) with errors <40% (<12%) on metallicity,<16% (4.8%) on temperature,2.6% (0.72%) on the gas density, and several single-element abundances.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2012

Estimate of the impact of background particles on the X-ray Microcalorimeter Spectrometer on IXO

Simone Lotti; E. Perinati; L. Natalucci; L. Piro; T. Mineo; L. Colasanti; C. Macculi

We present the results of a study on the impact of particles of galactic (GCR) and solar origin for the X-ray Microcalorimeter Spectrometer (XMS) aboard an astronomical satellite flying in an orbit at the second Lagrangian point (L2). The detailed configuration presented in this paper is the one adopted for the International X-ray Observatory (IXO) study, however the derived estimates can be considered a conservative limit for ATHENA, that is the IXO redefined mission proposed to ESA. This work is aimed at the estimate of the residual background level expected on the focal plane detector during the mission lifetime, a crucial information in the development of any instrumental configuration that optimizes the XMS scientific performances. We used the Geant4 toolkit, a Monte Carlo based simulator, to investigate the rejection efficiency of the anticoincidence system and assess the residual background on the detector.


Experimental Astronomy | 2017

The particle background of the X-IFU instrument

Simone Lotti; Teresa Mineo; Christian Jacquey; S. Molendi; Matteo D’Andrea; C. Macculi; Luigi Piro

In this paper we are going to review the latest estimates for the particle background expected on the X-IFU instrument onboard of the ATHENA mission. The particle background is induced by two different particle populations: the so called “soft protons” and the Cosmic rays. The first component is composed of low energy particles (< 100s keV) that get funnelled by the mirrors towards the focal plane, losing part of their energy inside the filters and inducing background counts inside the instrument sensitivity band. The latter component is induced by high energy particles (> 100 MeV) that possess enough energy to cross the spacecraft and reach the detector from any direction, depositing a small fraction of their energy inside the instrument. Both these components are estimated using Monte Carlo simulations and the latest results are presented here.


Proceedings of SPIE | 2016

The Cryogenic Anti-Coincidence detector for ATHENA X-IFU: pulse analysis of the AC-S7 single pixel prototype

Matteo D'Andrea; A. Argan; Simone Lotti; C. Macculi; Luigi Piro; M. Biasotti; D. Corsini; F. Gatti; G. Torrioli

The ATHENA observatory is the second large-class mission in ESA Cosmic Vision 2015-2025, with a launch foreseen in 2028 towards the L2 orbit. The mission addresses the science theme “The Hot and Energetic Universe”, by coupling a high-performance X-ray Telescope with two complementary focal-plane instruments. One of these is the X-ray Integral Field Unit (X-IFU): it is a TES based kilo-pixel order array able to provide spatially resolved high-resolution spectroscopy (2.5 eV at 6 keV) over a 5 arcmin FoV. The X-IFU sensitivity is degraded by the particles background expected at L2 orbit, which is induced by primary protons of both galactic and solar origin, and mostly by secondary electrons. To reduce the background level and enable the mission science goals, a Cryogenic Anticoincidence (CryoAC) detector is placed < 1 mm below the TES array. It is a 4- pixel TES based detector, with wide Silicon absorbers sensed by Ir:Au TESes. The CryoAC development schedule foresees by Q1 2017 the delivery of a Demonstration Model (DM) to the X-IFU FPA development team. The DM is a single-pixel detector that will address the final design of the CryoAC. It will verify some representative requirements at single-pixel level, especially the detector operation at 50 mK thermal bath and the threshold energy at 20 keV. To reach the final DM design we have developed and tested the AC-S7 prototype, with 1 cm2 absorber area sensed by 65 Ir TESes. Here we will discuss the pulse analysis of this detector, which has been illuminated by the 60 keV line from a 241Am source. First, we will present the analysis performed to investigate pulses timings and spectrum, and to disentangle the athermal component of the pulses from the thermal one. Furthermore, we will show the application to our dataset of an alternative method of pulse processing, based upon Principal Component Analysis (PCA). This kind of analysis allow us to recover better energy spectra than achievable with traditional methods, improving the evaluation of the detector threshold energy, a fundamental parameter characterizing the CryoAC particle rejection efficiency.


Proceedings of SPIE | 2016

The Cryogenic AntiCoincidence detector for ATHENA X-IFU: A program overview

C. Macculi; A. Argan; Matteo D'Andrea; Simone Lotti; M. Laurenza; Luigi Piro; M. Biasotti; D. Corsini; F. Gatti; G. Torrioli; M. Fiorini; S. Molendi; M. Uslenghi; T. Mineo; A. Bulgarelli; V. Fioretti; E. Cavazzuti

The ATHENA observatory is the second large-class ESA mission, in the context of the Cosmic Vision 2015 - 2025, scheduled to be launched on 2028 at L2 orbit. One of the two on-board instruments is the X-IFU (X-ray Integral Field Unit): it is a TES-based kilo-pixels order array able to perform simultaneous high-grade energy spectroscopy (2.5 eV at 6 keV) and imaging over the 5 arcmin FoV. The X-IFU sensitivity is degraded by the particles background which is induced by primary protons of both solar and Cosmic Rays origin, and secondary electrons. The studies performed by Geant4 simulations depict a scenario where it is mandatory the use of reduction techniques that combine an active anticoincidence detector and a passive electron shielding to reduce the background expected in L2 orbit down to the goal level of 0.005 cts/cm2/s/keV, so enabling the characterization of faint or diffuse sources (e.g. WHIM or Galaxy cluster outskirts). From the detector point of view this is possible by adopting a Cryogenic AntiCoincidence (CryoAC) placed within a proper optimized environment surrounding the X-IFU TES array. It is a 4-pixels detector made of wide area Silicon absorbers sensed by Ir TESes, and put at a distance < 1 mm below the TES-array. On October 2015 the X-IFU Phase A program has been kicked-off, and about the CryoAC is at present foreseen on early 2017 the delivery of the DM1 (Demonstration Model 1) to the FPA development team for integration, which is made of 1 pixel “bridgessuspended” that will address the final design of the CryoAC. Both the background studies and the detector development work is on-going to provide confident results about the expected residual background at the TES-array level, and the single pixel design to produce a detector for testing activity on 2016/2017. Here we will provide an overview of the CryoAC program, discussing some details about the background assessment having impact on the CryoAC design, the last single pixel characterization, the structural issues, followed by some programmatic aspects.


The Astrophysical Journal | 2016

NUSTAR AND XMM-NEWTON OBSERVATIONS OF 1E1743.1-2843: INDICATIONS OF A NEUTRON STAR LMXB NATURE OF THE COMPACT OBJECT

Simone Lotti; L. Natalucci; Kaya Mori; F. K. Baganoff; Steven E. Boggs; Finn Erland Christensen; William W. Craig; Charles J. Hailey; Fiona A. Harrison; JaeSub Hong; Roman A. Krivonos; Farid Rahoui; Daniel Stern; John A. Tomsick; Shuo Zhang; William W. Zhang

We report on the results of NuSTAR and XMM-Newton observations of the persistent X-ray source 1E1743.1-2843, located in the Galactic Center region. The source was observed between 2012 September and October by NuSTAR and XMM-Newton, providing almost simultaneous observations in the hard and soft X-ray bands. The high X-ray luminosity points to the presence of an accreting compact object. We analyze the possibilities of this accreting compact object being either a neutron star (NS) or a black hole, and conclude that the joint XMM-Newton and NuSTAR spectrum from 0.3 to 40 keV fits a blackbody spectrum with kT ~ 1.8 keV emitted from a hot spot or an equatorial strip on an NS surface. This spectrum is thermally Comptonized by electrons with kT_e ~ 4.6 keV. Accepting this NS hypothesis, we probe the low-mass X-ray binary (LMXB) or high-mass X-ray binary (HMXB) nature of the source. While the lack of Type-I bursts can be explained in the LMXB scenario, the absence of pulsations in the 2 mHz–49 Hz frequency range, the lack of eclipses and of an IR companion, and the lack of a K_ɑline from neutral or moderately ionized iron strongly disfavor interpreting this source as a HMXB. We therefore conclude that 1E1743.1-2843 is most likely an NS-LMXB located beyond the Galactic Center. There is weak statistical evidence for a soft X-ray excess which may indicate thermal emission from an accretion disk. However, the disk normalization remains unconstrained due to the high hydrogen column density (N_H ~ 1.6 x 10^(23)cm^(-2).


Proceedings of SPIE | 2016

Updates on the background estimates for the X-IFU instrument onboard of the ATHENA mission

Simone Lotti; C. Macculi; Matteo D'Andrea; Luigi Piro; S. Molendi; F. Gastaldello; Teresa Mineo; Antonino D'Ai; A. Bulgarelli; V. Fioretti; Christian Jacquey; M. Laurenza; Philippe Laurent

ATHENA is the second large mission in ESA Cosmic Vision 2015-2025, with a launch foreseen in 2028 towards the L2 orbit. The mission addresses the science theme “The Hot and Energetic Universe”, by coupling a high-performance X-ray Telescope with two complementary focal-plane instruments. One of these, the X-ray Integral Field Unit (X-IFU) is a TES based kilo-pixel array, providing spatially resolved high-resolution spectroscopy (2.5 eV at 6 keV) over a 5 arcmin FoV. The background for this kind of detectors accounts for several components: the diffuse Cosmic Xray Background, the low energy particles (< ~100 keV) focalized by the mirrors and reaching the detector from inside the field of view, and the high energy particles (> ~100 MeV) crossing the spacecraft and reaching the focal plane from every direction. In particular, these high energy particles lose energy in the materials they cross, creating secondaries along their path that can induce an additional background component. Each one of these components is under study of a team dedicated to the background issues regarding the X-IFU, with the aim to reduce their impact on the instrumental performances. This task is particularly challenging, given the lack of data on the background of X-ray detectors in L2, the uncertainties on the particle environment to be expected in such orbit, and the reliability of the models used in the Monte Carlo background computations. As a consequence, the activities addressed by the group range from the reanalysis of the data of previous missions like XMMNewton, to the characterization of the L2 environment by data analysis of the particle monitors onboard of satellites present in the Earth magnetotail, to the characterization of solar events and their occurrence, and to the validation of the physical models involved in the Monte Carlo simulations. All these activities will allow to develop a set of reliable simulations to predict, analyze and find effective solutions to reduce the particle background experienced by the X-IFU, ultimately satisfying the scientific requirement that enables the science of ATHENA. While the activities are still ongoing, we present here some preliminary results already obtained by the group. The L2 environment characterization activities, and the analysis and validation of the physical processes involved in the Monte Carlo simulations are the core of an ESA activity named AREMBES (Athena Radiation Environment Models and Effects), for which the work presented here represents a starting point.


Proceedings of SPIE | 2012

An efficient method for reducing the background of microcalorimeters applied to ATHENA-XMS

Simone Lotti; E. Perinati; L. Natalucci; L. Piro; T. Mineo; L. Colasanti; C. Macculi; M. Federici; B. Martino

We present several solutions to reduce the background that will be experienced by the X-ray Microcalorimeter Spectrometer (XMS) aboard of the ATHENA mission due to Galactic Cosmic Rays (GCR) and solar particles present in the second Lagrangian point L2. The configuration presented in this paper is the one adopted for the International X-ray Observatory (IXO) but the derived estimates can be considered a conservative limit for ATHENA, that is the IXO redefined mission proposed to ESA. We used the Geant4 toolkit, a Monte Carlo based simulator, to investigate the rejection efficiency of the anticoincidence system and assess the residual background on the detector. Even though the mission did not pass the down selection of ESA, this work lay the basis of a study for a microcalorimeters-based mission in L2.

Collaboration


Dive into the Simone Lotti's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

G. Torrioli

Istituto Nazionale di Fisica Nucleare

View shared research outputs
Researchain Logo
Decentralizing Knowledge