Wan Qin
University of Washington
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Wan Qin.
Circulation Research | 2015
Raluca Marcu; Surya Kotha; Zhongwei Zhi; Wan Qin; Christopher K. Neeley; Ruikang K. Wang; Ying Zheng; Brian J. Hawkins
RATIONALE The mitochondrial permeability transition pore is a well-known initiator of cell death that is increasingly recognized as a physiological modulator of cellular metabolism. OBJECTIVE We sought to identify how the genetic deletion of a key regulatory subunit of the mitochondrial permeability transition pore, cyclophilin D (CypD), influenced endothelial metabolism and intracellular signaling. METHODS AND RESULTS In cultured primary human endothelial cells, genetic targeting of CypD using siRNA or shRNA resulted in a constitutive increase in mitochondrial matrix Ca(2+) and reduced nicotinamide adenine dinucleotide (NADH). Elevated matrix NADH, in turn, diminished the cytosolic NAD(+)/NADH ratio and triggered a subsequent downregulation of the NAD(+)-dependent deacetylase sirtuin 1 (SIRT1). Downstream of SIRT1, CypD-deficient endothelial cells exhibited reduced phosphatase and tensin homolog expression and a constitutive rise in the phosphorylation of angiogenic Akt. Similar changes in SIRT1, phosphatase and tensin homolog, and Akt were also noted in the aorta and lungs of CypD knockout mice. Functionally, CypD-deficient endothelial cells and aortic tissue from CypD knockout mice exhibited a dramatic increase in angiogenesis at baseline and when exposed to vascular endothelial growth factor. The NAD(+) precursor nicotinamide mononucleotide restored the cellular NAD(+)/NADH ratio and normalized the CypD-deficient phenotype. CypD knockout mice also presented accelerated wound healing and increased neovascularization on tissue injury as monitored by optical microangiography. CONCLUSIONS Our study reveals the importance of the mitochondrial permeability transition pore in the regulation of endothelial mitochondrial metabolism and vascular function. The mitochondrial regulation of SIRT1 has broad implications in the epigenetic regulation of endothelial phenotype.
Journal of Biomedical Optics | 2016
Wei Wei; Jingjiang Xu; Utku Baran; Shaozhen Song; Wan Qin; Ruikang K. Wang
Abstract. We demonstrate in vivo volumetric optical microangiography at ∼200 volumes/s by the use of 1.6 MHz Fourier domain mode-locking swept source optical coherence tomography and an effective 36 kHz microelectromechanical system (MEMS) scanner. We propose an intervolume analysis strategy to contrast the dynamic blood flow signal from the static tissue background. The proposed system is demonstrated by imaging cerebral blood flow in mice in vivo. For the first time, imaging speed, sensitivity, and temporal resolution become possible for a direct four-dimensional observation of microcirculations within live body parts.
Journal of Biomedical Optics | 2014
Hequn Wang; Utku Baran; Yuandong Li; Wan Qin; Wenbo Wang; Haishan Zeng; Ruikang K. Wang
Abstract. Optical microangiography (OMAG) has been extensively utilized to study three-dimensional tissue vasculature in vivo. However, with the limited image resolution (∼10 μm) of the commonly used systems, some concerns were raised: (1) whether OMAG is capable of providing the imaging of capillary vessels that are of an average diameter of ∼6 μm; (2) if yes, whether OMAG can provide meaningful quantification of vascular density within the scanned tissue volume. Multiphoton microscopy (MPM) is capable of depth-resolved high-resolution (∼1 μm) imaging of biological tissue structures. With externally labeled plasma, the vascular network including single capillaries can be well visualized. We compare the vascular images of in vivo mouse brain acquired by both OMAG and MPM systems. We found that within the penetration depth range of the MPM system, OMAG is able to accurately visualize blood vessels including capillaries. Although the resolution of OMAG may not be able to 100% resolve two closely packed tiny capillaries in tissue, it is still capable of visualizing most of the capillaries because there are interstitial tissue spaces between them. We believe our validation results reinforce the application of OMAG in microvasculature-related studies.
Scientific Reports | 2016
Utku Baran; Wan Qin; Xiaoli Qi; Goknur Kalkan; Ruikang K. Wang
Due to the limitations of current imaging techniques, visualization of lymphatic capillaries within tissue in vivo has been challenging. Here, we present a label-free high resolution optical coherence tomography (OCT) based lymphangiography (OLAG) within human skin in vivo. OLAG enables rapid (~seconds) mapping of lymphatic networks, along with blood vessel networks, over 8 mm x 8 mm of human skin and 5 mm x 5 mm of human areola. Moreover, lymphatic system’s response to inflammation within human skin is monitored throughout an acne lesion development over 7 days. The demonstrated results promise OLAG as a revolutionary tool in the clinical research and treatment of patients with pathologic conditions such as cancer, diabetes, and autoimmune diseases.
Biomedical Optics Express | 2016
Woo June Choi; Yuandong Li; Wan Qin; Ruikang K. Wang
We propose a new optical coherence tomography (OCT) based method to measure red blood cell (RBC) velocities of single capillaries in the cortex of rodent brain. This OCT capillary velocimetry exploits quantitative laser speckle contrast analysis to estimate speckle decorrelation rate from the measured temporal OCT speckle signals, which is related to microcirculatory flow velocity. We hypothesize that OCT signal due to sub-surface capillary flow can be treated as the speckle signal in the single scattering regime and thus its time scale of speckle fluctuations can be subjected to single scattering laser speckle contrast analysis to derive characteristic decorrelation time. To validate this hypothesis, OCT measurements are conducted on a single capillary flow phantom operating at preset velocities, in which M-mode B-frames are acquired using a high-speed OCT system. Analysis is then performed on the time-varying OCT signals extracted at the capillary flow, exhibiting a typical inverse relationship between the estimated decorrelation time and absolute RBC velocity, which is then used to deduce the capillary velocities. We apply the method to in vivo measurements of mouse brain, demonstrating that the proposed approach provides additional useful information in the quantitative assessment of capillary hemodynamics, complementary to that of OCT angiography.
Biomedical Optics Express | 2016
Woo June Choi; Wan Qin; Chieh-Li Chen; Jingang Wang; Qinqin Zhang; Xiaoqi Yang; Bruce Z. Gao; Ruikang K. Wang
Optical microangiography (OMAG) is a powerful optical angio-graphic tool to visualize micro-vascular flow in vivo. Despite numerous demonstrations for the past several years of the qualitative relationship between OMAG and flow, no convincing quantitative relationship has been proven. In this paper, we attempt to quantitatively correlate the OMAG signal with flow. Specifically, we develop a simplified analytical model of the complex OMAG, suggesting that the OMAG signal is a product of the number of particles in an imaging voxel and the decorrelation of OCT (optical coherence tomography) signal, determined by flow velocity, inter-frame time interval, and wavelength of the light source. Numerical simulation with the proposed model reveals that if the OCT amplitudes are correlated, the OMAG signal is related to a total number of particles across the imaging voxel cross-section per unit time (flux); otherwise it would be saturated but its strength is proportional to the number of particles in the imaging voxel (concentration). The relationship is validated using microfluidic flow phantoms with various preset flow metrics. This work suggests OMAG is a promising quantitative tool for the assessment of vascular flow.
Lasers in Surgery and Medicine | 2015
Wan Qin; Utku Baran; Ruikang K. Wang
Optical microangiography (OMAG) is a noninvasive technique capable of imaging 3D microvasculature. OMAG‐based optical lymphangiography has been developed for 3D visualization of lymphatic vessels without the need for exogenous contrast agents. In this study, we utilize the optical lymphangiography to investigate dynamic changes in lymphatic response within skin tissue to depilation‐induced inflammation by using mouse ear as a simple tissue model.
Journal of Neuroscience Methods | 2016
Yuandong Li; Woo June Choi; Wan Qin; Utku Baran; Lauren M. Habenicht; Ruikang K. Wang
BACKGROUND Arteriogenesis describes the active growth of the pre-existing collateral arterioles, which is a crucial tissue-saving process in occlusive vascular diseases. NEW METHOD We propose to use optical coherence tomography (OCT)-based microangiography (OMAG) to monitor arteriogenesis following artery transection in mouse ear and focal stroke in mouse brain. RESULTS Our longitudinal mouse ear study shows that the growth phase of arteriogenesis, indicated by changes in collateral vessel diameter and velocity, occurs between 12 and 24h after vessel transection. Additionally, the magnitude of local inflammation is consistent with the time course of arteriogenesis, judging by the tissue thickness measurement and lymphatic vessel signals in OCT. In the mouse brain study, collateral vessel morphology, blood flow velocity and directionality are identified, and an activation of the collateral flow at the arteriolo-arteriolar anastomoses (AAA) is observed during stroke. COMPARISON WITH EXISTING METHODS In comparison with histology and fluorescence imaging, OCT/OMAG is completely non-invasive and capable of producing consistent results of longitudinal changes in collateral vessel morphology and vasodynamics. CONCLUSION OCT/OMAG is a promising imaging tool for longitudinal study of collateral vessel remodeling in small animals. This technique can be applied in guiding the in vivo experiments of arteriogenesis stimulation to treat occlusive vascular diseases, including stroke.
Physics in Medicine and Biology | 2016
Wan Qin; Meredith Roberts; Charles E. Murry; Ying Zheng; Ruikang K. Wang
In this study, we propose a novel implementation of optical coherence tomography-based angiography combined with ex vivo perfusion of fixed hearts to visualize coronary microvascular structure and function. The extracorporeal perfusion of Intralipid solution allows depth-resolved angiographic imaging, control of perfusion pressure, and high-resolution optical microangiography. The imaging technique offers new opportunities for microcirculation research in the heart, which has been challenging due to motion artifacts and the lack of independent control of pressure and flow. With the ability to precisely quantify structural and functional features, this imaging platform has broad potential for the study of the pathophysiology of microvasculature in the heart as well as other organs.
Proceedings of SPIE | 2017
Woo June Choi; Wan Qin; Chieh-Li Chen; Jingang Wang; Qinqin Zhang; Ruikang K. Wang
Optical microangiography (OMAG) is a powerful optical angiographic tool to visualize micro-vascular flow in vivo. Despite numerous demonstrations for the past several years of the qualitative relationship between OMAG and flow, no convincing quantitative relationship has been proven. In this paper, we attempt to quantitatively correlate the OMAG signal with flow. Specifically, we develop a simplified analytical model of the complex OMAG, suggesting that the OMAG signal is a product of the number of particles in an imaging voxel and the decorrelation of OCT (optical coherence tomography) signal, determined by flow velocity, interframe time interval, and wavelength of the light source. Numerical simulation with the proposed model reveals that if the OCT amplitudes are correlated, the OMAG signal is related to a total number of particles across the imaging voxel cross-section per unit time (flux); otherwise it would be saturated but its strength is proportional to the number of particles in the imaging voxel (concentration). The relationship is validated using microfluidic flow phantoms with various preset flow metrics. This work suggests OMAG is a promising quantitative tool for the assessment of vascular flow.