X. Lojacono
University of Lyon
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by X. Lojacono.
ieee nuclear science symposium | 2011
M.-H. Richard; M. Dahoumane; D. Dauvergne; M. De Rydt; George Dedes; N. Freud; J. Krimmer; J.M. Létang; X. Lojacono; V. Maxim; G. Montarou; C. Ray; F. Roellinghoff; E. Testa; A.H. Walenta
The goal of this study is to tune the design of the absorber detector of a Compton camera for prompt γ-ray imaging during ion beam therapy. The response of the Compton camera to a photon point source with a realistic energy spectrum (corresponding to the prompt γ-ray spectrum emitted during the carbon irradiation of a water phantom) is studied by means of Geant4 simulations. Our Compton camera consists of a stack of 2 mm thick silicon strip detectors as a scatter detector and of a scintillator plate as an absorber detector. Four scintillators are considered: LYSO, NaI, LaBr3 and BGO. LYSO and BGO appear as the most suitable materials, due to their high photo-electric cross-sections, which leads to a high percentage of fully absorbed photons. Depth-of-interaction measurements are shown to have limited influence on the spatial resolution of the camera. In our case, the thickness which gives the best compromise between a high percentage of photons that are fully absorbed and a low parallax error is about 4 cm for the LYSO detector and 4.5 cm for the BGO detector. The influence of the width of the absorber detector on the spatial resolution is not very pronounced as long as it is lower than 30 cm.
Physics in Medicine and Biology | 2016
V. Maxim; X. Lojacono; E. Hilaire; J. Krimmer; E. Testa; D. Dauvergne; Isabelle E. Magnin; Rémy Prost
This paper addresses the problem of evaluating the system matrix and the sensitivity for iterative reconstruction in Compton camera imaging. Proposed models and numerical calculation strategies are compared through the influence they have on the three-dimensional reconstructed images. The study attempts to address four questions. First, it proposes an analytic model for the system matrix. Second, it suggests a method for its numerical validation with Monte Carlo simulated data. Third, it compares analytical models of the sensitivity factors with Monte Carlo simulated values. Finally, it shows how the system matrix and the sensitivity calculation strategies influence the quality of the reconstructed images.
IEEE Transactions on Nuclear Science | 2013
X. Lojacono; M.-H. Richard; Jean-Luc Ley; E. Testa; C. Ray; N. Freud; J.M. Létang; D. Dauvergne; V. Maxim; Rémy Prost
The Compton camera is a relevant imaging device for the detection of prompt photons produced by nuclear fragmentation in hadrontherapy. It may allow an improvement in detection efficiency compared to a standard gamma-camera but requires more sophisticated image reconstruction techniques. In this work, we simulate low statistics acquisitions from a point source having a broad energy spectrum compatible with hadrontherapy. We then reconstruct the image of the source with a recently developed filtered backprojection algorithm, a line-cone approach and an iterative List Mode Maximum Likelihood Expectation Maximization algorithm. Simulated data come from a Compton camera prototype designed for hadrontherapy online monitoring. Results indicate that the achievable resolution in directions parallel to the detector, that may include the beam direction, is compatible with the quality control requirements. With the prototype under study, the reconstructed image is elongated in the direction orthogonal to the detector. However this direction is of less interest in hadrontherapy where the first requirement is to determine the penetration depth of the beam in the patient. Additionally, the resolution may be recovered using a second camera.
ieee nuclear science symposium | 2011
X. Lojacono; M.-H. Richard; C. Ray; D. Dauvergne; E. Testa; N. Freud; J.M. Létang; V. Maxim; Rémy Prost
The Compton camera is an imaging device relevant for the detection of prompt photons produced during nuclear fragmentation in hadrontherapy. It allows a considerable improvement in detection compared to a standard gamma-camera but also requires more sophisticated image reconstruction techniques. In this work we apply a recently developed filtered backprojection algorithm to data simulated from a realistic Compton camera prototype designed for hadrontherapy on-line monitoring. We reconstruct images of a point source having a broad energy spectrum compatible with the up-mentioned application. Preliminary results indicate that the achievable resolution in directions parallel to the camera, thus including the beam direction, are compatible with the quality control requirements. With the prototype under study, the reconstructed image is elongated in the direction orthogonal to the camera. However this direction is of less interest and the resolution may be easily recovered using a second camera.
international conference on advancements in nuclear instrumentation measurement methods and their applications | 2013
J. Krimmer; L. Balleyguier; J. Baudot; S. Brons; L. Caponetto; M. Chabot; X. Chen; M. Dahoumane; D. Dauvergne; M. De Rydt; George Dedes; R. Della Negra; S. Deng; P. Force; N. Freud; Baptiste Joly; J. Hérault; Christophe Insa; D. Lambert; C. La Tessa; Loïc Lestand; J.M. Létang; J.-L. Ley; X. Lojacono; M. Magne; H. Mathez; V. Maxim; G. Montarou; Katia Parodi; M. Pinto
Prompt secondary radiations such as gamma rays and protons can be used for ion-range monitoring during ion therapy either on an energy-slice basis or on a pencil-beam basis. We present a review of the ongoing activities in terms of detector developments, imaging, experimental and theoretical physics issues concerning the correlation between the physical dose and hadronic processes.
Archive | 2013
X. Lojacono
ICTR-PHE 2014 | 2014
E. Hilaire; Charlotte Robert; X. Lojacono; David Sarrut; Irène Buvat; Françoise Peyrin; V. Maxim
XXIVème Colloque GRETSI - Traitement du Signal et des Images (GRETSI'13) | 2013
E. Hilaire; Charlotte Robert; X. Lojacono; Carole Lartizien; Irène Buvat; V. Maxim
Workshop "The future of radiation oncology : Imaging, Dosimetry, Biology & Therapy" | 2013
E. Hilaire; X. Lojacono; Rémy Prost; V. Maxim; Françoise Peyrin
Interdisciplinary Symposium on Signals and Systems for Medical Applications | 2013
E. Hilaire; Charlotte Robert; X. Lojacono; Carole Lartizien; Irène Buvat; V. Maxim