Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Xueyun Zheng is active.

Publication


Featured researches published by Xueyun Zheng.


Analytical and Bioanalytical Chemistry | 2017

Enhancing glycan isomer separations with metal ions and positive and negative polarity ion mobility spectrometry-mass spectrometry analyses.

Xueyun Zheng; Xing Zhang; Nathaniel S. Schocker; Ryan S. Renslow; Daniel J. Orton; Jamal Khamsi; Roger A. Ashmus; Igor C. Almeida; Keqi Tang; Catherine E. Costello; Richard D. Smith; Katja Michael; Erin S. Baker

AbstractGlycomics has become an increasingly important field of research since glycans play critical roles in biology processes ranging from molecular recognition and signaling to cellular communication. Glycans often conjugate with other biomolecules, such as proteins and lipids, and alter their properties and functions, so glycan characterization is essential for understanding the effects they have on cellular systems. However, the analysis of glycans is extremely difficult due to their complexity and structural diversity (i.e., the number and identity of monomer units, and configuration of their glycosidic linkages and connectivities). In this work, we coupled ion mobility spectrometry with mass spectrometry (IMS-MS) to characterize glycan standards and biologically important isomers of synthetic αGal-containing O-glycans including glycotopes of the protozoan parasite Trypanosoma cruzi, which is the causative agent of Chagas disease. IMS-MS results showed significant differences for the glycan structural isomers when analyzed in positive and negative polarity and complexed with different metal cations. These results suggest that specific metal ions or ion polarities could be used to target and baseline separate glycan isomers of interest with IMS-MS. Graphical abstractGlycan isomers, such as fructose and glucose, show distinct separations in positive and negative ion mode


Analytical Chemistry | 2017

An Interlaboratory Evaluation of Drift Tube Ion Mobility–Mass Spectrometry Collision Cross Section Measurements

Sarah M. Stow; Tim J. Causon; Xueyun Zheng; Ruwan T. Kurulugama; Teresa Mairinger; Jody C. May; Emma E. Rennie; Erin S. Baker; Richard D. Smith; John A. McLean; Stephan Hann; John C. Fjeldsted

Collision cross section (CCS) measurements resulting from ion mobility-mass spectrometry (IM-MS) experiments provide a promising orthogonal dimension of structural information in MS-based analytical separations. As with any molecular identifier, interlaboratory standardization must precede broad range integration into analytical workflows. In this study, we present a reference drift tube ion mobility mass spectrometer (DTIM-MS) where improvements on the measurement accuracy of experimental parameters influencing IM separations provide standardized drift tube, nitrogen CCS values (DTCCSN2) for over 120 unique ion species with the lowest measurement uncertainty to date. The reproducibility of these DTCCSN2 values are evaluated across three additional laboratories on a commercially available DTIM-MS instrument. The traditional stepped field CCS method performs with a relative standard deviation (RSD) of 0.29% for all ion species across the three additional laboratories. The calibrated single field CCS method, which is compatible with a wide range of chromatographic inlet systems, performs with an average, absolute bias of 0.54% to the standardized stepped field DTCCSN2 values on the reference system. The low RSD and biases observed in this interlaboratory study illustrate the potential of DTIM-MS for providing a molecular identifier for a broad range of discovery based analyses.


Analytical Chemistry | 2016

Achieving High Resolution Ion Mobility Separations Using Traveling Waves in Compact Multiturn Structures for Lossless Ion Manipulations

Ahmed M. Hamid; Sandilya V. B. Garimella; Yehia M. Ibrahim; Liulin Deng; Xueyun Zheng; Ian K. Webb; Gordon A. Anderson; Spencer A. Prost; Randolph V. Norheim; Aleksey V. Tolmachev; Erin S. Baker; Richard D. Smith

We report on ion mobility (IM) separations achievable using traveling waves (TW) in a Structures for Lossless Ion Manipulations (SLIM) module having a 44 cm path length and 16 90° turns. The performance of the TW-SLIM module was evaluated for ion transmission and IM separations with different RF, TW parameters, and SLIM surface gaps in conjunction with mass spectrometry. In this work, TWs were created by the transient and dynamic application of DC potentials. The module demonstrated highly robust performance and, even with 16 closely spaced turns, achieving IM resolution performance and ion transmission comparable to a similar straight path module. We found an IM peak capacity of ∼31 and peak generation rate of 780 s(-1) for TW speeds of ∼80 m/s using the current multi-turn TW-SLIM module. The separations achieved for isomers of peptides and tetrasaccharides were found to be comparable to those from a ∼0.9-m drift tube-based IM-MS platform operated at the same pressure (4 Torr). The combined attributes of flexible design, low voltage requirements and lossless ion transmission through multiple turns for the present TW-SLIM module provides a basis for SLIM devices capable of achieving much greater IM resolution via greatly extended ion path lengths and using compact serpentine designs.


Reviews in Analytical Chemistry | 2017

Coupling Front-End Separations, Ion Mobility Spectrometry, and Mass Spectrometry for Enhanced Multidimensional Biological and Environmental Analyses

Xueyun Zheng; Roza Wojcik; Xing Zhang; Yehia M. Ibrahim; Kristin E. Burnum-Johnson; Daniel J. Orton; Matthew E. Monroe; Ronald J. Moore; Richard D. Smith; Erin S. Baker

Ion mobility spectrometry (IMS) is a widely used analytical technique for rapid molecular separations in the gas phase. Though IMS alone is useful, its coupling with mass spectrometry (MS) and front-end separations is extremely beneficial for increasing measurement sensitivity, peak capacity of complex mixtures, and the scope of molecular information available from biological and environmental sample analyses. In fact, multiple disease screening and environmental evaluations have illustrated that the IMS-based multidimensional separations extract information that cannot be acquired with each technique individually. This review highlights three-dimensional separations using IMS-MS in conjunction with a range of front-end techniques, such as gas chromatography, supercritical fluid chromatography, liquid chromatography, solid-phase extractions, capillary electrophoresis, field asymmetric ion mobility spectrometry, and microfluidic devices. The origination, current state, various applications, and future capabilities of these multidimensional approaches are described in detail to provide insight into their uses and benefits.


Analytical Chemistry | 2017

Serpentine Ultralong Path with Extended Routing (SUPER) High Resolution Traveling Wave Ion Mobility-MS using Structures for Lossless Ion Manipulations

Liulin Deng; Ian K. Webb; Sandilya V. B. Garimella; Ahmed M. Hamid; Xueyun Zheng; Randolph V. Norheim; Spencer A. Prost; Gordon A. Anderson; Jeremy A. Sandoval; Erin S. Baker; Yehia M. Ibrahim; Richard D. Smith

Ion mobility (IM) separations have a broad range of analytical applications, but insufficient resolution often limits their utility. Here, we report on ion mobility separations in a structures for lossless ion manipulations (SLIM) serpentine ultralong path with extended routing (SUPER) traveling wave (TW) ion mobility (IM) module in conjunction with mass spectrometry (MS). Ions were confined in the SLIM by rf fields in conjunction with a DC guard bias, enabling essentially lossless TW transmission over greatly extended paths. The extended routing utilized multiple passes (e.g., ∼1094 m over 81 passes through the 13.5 m serpentine path) and was facilitated by the introduction of a lossless ion switch that allowed ions to be directed to either the MS detector or for another pass through the serpentine separation region, allowing theoretically unlimited IM path lengths. The multipass SUPER IM-MS provided resolution approximately proportional to the square root of the number of passes (or total path length). More than 30-fold higher IM resolution (∼340 vs ∼10) for Agilent tuning mix m/z 622 and 922 ions was achieved for 40 passes compared to commercially available drift tube IM and other TWIM-based platforms. An initial evaluation of the isomeric sugars lacto-N-hexaose and lacto-N-neohexaose showed the isomeric structures to be baseline resolved, and a new conformational feature for lacto-N-neohexaose was revealed after 9 passes. The new SLIM SUPER high resolution TWIM platform has broad utility in conjunction with MS and is expected to enable a broad range of previously challenging or intractable separations.


Journal of Physical Chemistry Letters | 2017

Structural Elucidation of cis/trans Dicaffeoylquinic Acid Photoisomerization Using Ion Mobility Spectrometry-Mass Spectrometry

Xueyun Zheng; Ryan S. Renslow; Mpho M. Makola; Ian K. Webb; Liulin Deng; Dennis G. Thomas; Niranjan Govind; Yehia M. Ibrahim; Mwadham M. Kabanda; Ian A. Dubery; Heino M. Heyman; Richard D. Smith; Ntakadzeni E. Madala; Erin S. Baker

Due to the recently uncovered health benefits and anti-HIV activities of dicaffeoylquinic acids (diCQAs), understanding their structures and functions is of great interest for drug discovery efforts. DiCQAs are analytically challenging to identify and quantify since they commonly exist as a diverse mixture of positional and geometric (cis/trans) isomers. In this work, we utilized ion mobility spectrometry coupled with mass spectrometry to separate the various isomers before and after UV irradiation. The experimental collision cross sections were then compared with theoretical structures to differentiate and identify the diCQA isomers. Our analyses found that naturally the diCQAs existed predominantly as trans/trans isomers, but after 3 h of UV irradiation, cis/cis, cis/trans, trans/cis, and trans/trans isomers were all present in the mixture. This is the first report of successful differentiation of cis/trans diCQA isomers individually, which shows the great promise of IMS coupled with theoretical calculations for determining the structure and activity relationships of different isomers in drug discovery studies.


Clinical Mass Spectrometry | 2016

SPE-IMS-MS: An automated platform for sub-sixty second surveillance of endogenous metabolites and xenobiotics in biofluids

Xing Zhang; Michelle Romm; Xueyun Zheng; Erika M. Zink; Young Mo Kim; Kristin E. Burnum-Johnson; Daniel J. Orton; Alex Apffel; Yehia M. Ibrahim; Matthew E. Monroe; Ronald J. Moore; Jordan N. Smith; Jian Ma; Ryan S. Renslow; Dennis G. Thomas; Anne E. Blackwell; Glenn Swinford; John Sausen; Ruwan T. Kurulugama; Nathan Eno; Ed Darland; George Stafford; John Fjeldsted; Thomas O. Metz; Justin G. Teeguarden; Richard D. Smith; Erin S. Baker

Characterization of endogenous metabolites and xenobiotics is essential to deconvoluting the genetic and environmental causes of disease. However, surveillance of chemical exposure and disease-related changes in large cohorts requires an analytical platform that offers rapid measurement, high sensitivity, efficient separation, broad dynamic range, and application to an expansive chemical space. Here, we present a novel platform for small molecule analyses that addresses these requirements by combining solid-phase extraction with ion mobility spectrometry and mass spectrometry (SPE-IMS-MS). This platform is capable of performing both targeted and global measurements of endogenous metabolites and xenobiotics in human biofluids with high reproducibility (CV 6 3%), sensitivity (LODs in the pM range in biofluids) and throughput (10-s sample-to-sample duty cycle). We report application of this platform to the analysis of human urine from patients with and without type 1 diabetes, where we observed statistically significant variations in the concentration of disaccharides and previously unreported chemical isomers. This SPE-IMS-MS platform overcomes many of the current challenges of large-scale metabolomic and exposomic analyses and offers a viable option for population and patient cohort screening in an effort to gain insights into disease processes and human environmental chemical exposure.


Analytical Chemistry | 2018

Online Ozonolysis Combined with Ion Mobility-Mass Spectrometry Provides a New Platform for Lipid Isomer Analyses

Berwyck L. J. Poad; Xueyun Zheng; Todd W. Mitchell; Richard D. Smith; Erin S. Baker; Stephen J. Blanksby

One of the most significant challenges in contemporary lipidomics lies in the separation and identification of lipid isomers that differ only in site(s) of unsaturation or geometric configuration of the carbon-carbon double bonds. While analytical separation techniques including ion mobility spectrometry (IMS) and liquid chromatography (LC) can separate isomeric lipids under appropriate conditions, conventional tandem mass spectrometry cannot provide unequivocal identification. To address this challenge, we have implemented ozone-induced dissociation (OzID) in-line with LC, IMS, and high resolution mass spectrometry. Modification of an IMS-capable quadrupole time-of-flight mass spectrometer was undertaken to allow the introduction of ozone into the high-pressure trapping ion funnel region preceding the IMS cell. This enabled the novel LC-OzID-IMS-MS configuration where ozonolysis of ionized lipids occurred rapidly (10 ms) without prior mass-selection. LC-elution time alignment combined with accurate mass and arrival time extraction of ozonolysis products facilitated correlation of precursor and product ions without mass-selection (and associated reductions in duty cycle). Unsaturated lipids across 11 classes were examined using this workflow in both positive and negative ion modalities, and in all cases, the positions of carbon-carbon double bonds were unequivocally assigned based on predictable OzID transitions. Under these conditions, geometric isomers exhibited different IMS arrival time distributions and distinct OzID product ion ratios providing a means for discrimination of cis/trans double bonds in complex lipids. The combination of OzID with multidimensional separations shows significant promise for facile profiling of unsaturation patterns within complex lipidomes including human plasma.


Rapid Communications in Mass Spectrometry | 2017

Comparing identified and statistically significant lipids and polar metabolites in 15-year old serum and dried blood spot samples for longitudinal studies

Jennifer E. Kyle; Cameron P. Casey; Kelly G. Stratton; Erika M. Zink; Young Mo Kim; Xueyun Zheng; Matthew E. Monroe; Karl K. Weitz; Kent J. Bloodsworth; Daniel J. Orton; Yehia M. Ibrahim; Ronald J. Moore; Christine G. Lee; Catherine Pedersen; Eric S. Orwoll; Richard D. Smith; Kristin E. Burnum-Johnson; Erin S. Baker

RATIONALE The use of dried blood spots (DBS) has many advantages over traditional plasma and serum samples such as the smaller blood volume required, storage at room temperature, and ability to sample in remote locations. However, understanding the robustness of different analytes in DBS samples is essential, especially in older samples collected for longitudinal studies. METHODS Here we analyzed the stability of polar metabolites and lipids in DBS samples collected in 2000-2001 and stored at room temperature. The identified and statistically significant molecules were then compared to matched serum samples stored at -80°C to determine if the DBS samples could be effectively used in a longitudinal study following metabolic disease. RESULTS A total of 400 polar metabolites and lipids were identified in the serum and DBS samples using gas chromatograph/mass spectrometry (GC/MS), liquid chromatography (LC)/MS, and LC/ion mobility spectrometry-MS (LC/IMS-MS). The identified polar metabolites overlapped well between the sample types, though only one statistically significant metabolite was conserved in a case-control study of older diabetic males with low amounts of high-density lipoproteins and high body mass indices, triacylglycerides and glucose levels when compared to non-diabetic patients with normal levels, indicating that degradation in the DBS samples affects polar metabolite quantitation. Differences in the lipid identifications indicated that some oxidation occurs in the DBS samples. However, 36 statistically significant lipids correlated in both sample types. CONCLUSIONS The difference in the number of statistically significant polar metabolites and lipids indicated that the lipids did not degrade to as great of a degree as the polar metabolites in the DBS samples and lipid quantitation was still possible. Copyright


Current Opinion in Chemical Biology | 2018

Recent advances in lipid separations and structural elucidation using mass spectrometry combined with ion mobility spectrometry, ion-molecule reactions and fragmentation approaches

Xueyun Zheng; Richard D. Smith; Erin S. Baker

Lipids are a vital class of molecules that play important and varied roles in biological processes, however, fully understanding these roles is extremely difficult due to the immense number and diversity of possible lipid species. While recent advances in chromatography and high resolution mass spectrometry have greatly progressed knowledge about distinct lipid species and functions, effectively separating many lipids still remains problematic. Isomeric lipids have made lipid characterization especially difficult and occur due to subclasses having the same chemical composition, or species having multiple acyl chain connectivities (sn-1, sn-2, or sn-3), double bond positions and orientations (cis or trans), and functional group stereochemistries (R versus S). To aid in isomer characterization, ion mobility spectrometry separations, ion-molecule reactions and fragmentation techniques have increasingly been added to lipid analysis workflows. In this manuscript, we review the current state of these approaches and their capabilities for improving the identification of lipid species.

Collaboration


Dive into the Xueyun Zheng's collaboration.

Top Co-Authors

Avatar

Erin S. Baker

Pacific Northwest National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Richard D. Smith

Pacific Northwest National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Yehia M. Ibrahim

Pacific Northwest National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Daniel J. Orton

Pacific Northwest National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Liulin Deng

Pacific Northwest National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Ian K. Webb

Pacific Northwest National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Matthew E. Monroe

Pacific Northwest National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Ahmed M. Hamid

Virginia Commonwealth University

View shared research outputs
Top Co-Authors

Avatar

Kristin E. Burnum-Johnson

Pacific Northwest National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Randolph V. Norheim

Pacific Northwest National Laboratory

View shared research outputs
Researchain Logo
Decentralizing Knowledge