Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Charles Timchalk is active.

Publication


Featured researches published by Charles Timchalk.


Journal of Hazardous Materials | 2010

Selective Capture of Cesium and Thallium from Natural Waters and Simulated Wastes with Copper Ferrocyanide Functionalized Mesoporous Silica

Thanapon Sangvanich; Vichaya Sukwarotwat; Robert J. Wiacek; Rafal M. Grudzien; Glen E. Fryxell; R. Shane Addleman; Charles Timchalk; Wassana Yantasee

Copper(II) ferrocyanide on mesoporous silica (FC-Cu-EDA-SAMMS) has been evaluated against iron(III) hexacyanoferrate(II) (insoluble Prussian Blue) for removing cesium (Cs(+)) and thallium (Tl(+)) from natural waters and simulated acidic and alkaline wastes. From pH 0.1-7.3, FC-Cu-EDA-SAMMS had greater affinities for Cs and Tl and was less affected by the solution pH, competing cations, and matrices. SAMMS also outperformed Prussian Blue in terms of adsorption capacities (e.g., 21.7 versus 2.6 mg Cs/g in acidic waste stimulant (pH 1.1), 28.3 versus 5.8 mg Tl/g in seawater), and rate (e.g., over 95 wt% of Cs was removed from seawater after 2 min with SAMMS, while only 75 wt% was removed with Prussian Blue). SAMMS also had higher stability (e.g., 2.5-13-fold less Fe dissolved from 2 to 24 h of contact time). In addition to environmental applications, SAMMS has great potential to be used as orally administered drug for limiting the absorption of radioactive Cs and toxic Tl in gastrointestinal tract.


Analytical Chemistry | 2010

Quantum dot-based immunochromatographic fluorescent biosensor for biomonitoring trichloropyridinol, a biomarker of exposure to chlorpyrifos.

Zhexiang Zou; Dan Du; Jun Wang; Jordan N. Smith; Charles Timchalk; Yaoqun Li; Yuehe Lin

A novel and portable fluorescent sensor that integrates an immunochromatographic test strip assay (ITSA) with a quantum dot (QD) label and a test strip reader was described in this study for simple, rapid, and sensitive biomonitoring of an organophosphorus pesticide metabolite. The principle of this sensor is based on a competitive immunoreaction that was performed on an immunochromatographic test strip, where analytes compete with competitors (QD-conjugated analogs) to bind to antibodies on a test zone. Captured QDs serve as signal vehicles for fluorescent readout. In this work, 3,5,6-trichloropyridinol (TCP) is used as a model analyte to demonstrate the performance of the immunosensor. QD-TCP conjugates were synthesized and characterized with X-ray photoelectron spectroscopy (XPS) and fluorescence spectroscopy. Some parameters (e.g., the amount of QD-modified TCP and immunoreaction time) that govern sensitivity and reproducibility of ITSA were optimized. Under optimal conditions, the sensor has a wide dynamic range and is capable of detecting a minimum 1.0 ng/mL TCP standard analyte in 15 min. The sensor has been successfully applied for detection of TCP spiked in rat plasma with average recovery of 102.0%. Results demonstrate that this sensor provides a rapid, clinically accurate, and quantitative tool for TCP detection and shows great promise for in-field and point-of-care (POC) quantitative testing and screening for metabolite biomarkers, e.g., TCP, for humans exposed to pesticides.


Analytical Chemistry | 2008

Magnetic Electrochemical Immunoassays with Quantum Dot Labels for Detection of Phosphorylated Acetylcholinesterase in Plasma

Hua Wang; Jun Wang; Charles Timchalk; Yuehe Lin

A new magnetic electrochemical immunoassay has been developed as a tool for biomonitoring exposures to organophosphate (OP) compounds, e.g., insecticides and chemical nerve agents, by directly detecting organophosphorylated acetylcholinesterase (OP-AChE). This immunoassay uniquely incorporates highly efficient magnetic separation with ultrasensitive square wave voltammetry (SWV) analysis with quantum dots (QDs) as labels. A pair of antibodies was used to achieve the specific recognition of OP-AChE that was prepared with paraoxon as an OP model agent. Antiphosphoserine polyclonal antibodies were anchored on amorphous magnetic particles preferably chosen to capture OP-AChE from the sample matrixes by binding their phosphoserine moieties that were exposed through unfolding the protein adducts. This was validated by electrochemical examinations and enzyme-linked immunosorbent assays. Furthermore, antihuman AChE monoclonal antibodies were labeled with cadmium-source QDs to selectively recognize the captured OP-AChE, as characterized by transmission electron microscopy. The subsequent electrochemical SWV analysis of the cadmium component released by acid from the coupled QDs was conducted on disposable screen-printed electrodes. Experimental results indicated that the SWV-based immunoassays could yield a linear response over a broad concentration range of 0.3-300 ng/mL OP-AChE in human plasma with a detection limit of 0.15 ng/mL. Such a novel electrochemical immunoassay holds great promise as a simple, selective, sensitive, and field-deployable tool for the effective biomonitoring and diagnosis of potential exposures to nerve agents and pesticides.


Chemistry: A European Journal | 2008

Nanoparticle‐Based Electrochemical Immunosensor for the Detection of Phosphorylated Acetylcholinesterase: An Exposure Biomarker of Organophosphate Pesticides and Nerve Agents

Guodong Liu; Jun Wang; Richard C. Barry; Catherine E. Petersen; Charles Timchalk; Paul L. Gassman; Yuehe Lin

A nanoparticle-based electrochemical immunosensor has been developed for the detection of phosphorylated acetylcholinesterase (AChE), which is a potential biomarker of exposure to organophosphate (OP) pesticides and chemical warfare nerve agents. Zirconia nanoparticles (ZrO(2) NPs) were used as selective sorbents to capture the phosphorylated AChE adduct, and quantum dots (ZnS@CdS, QDs) were used as tags to label monoclonal anti-AChE antibody to quantify the immunorecognition events. The sandwich-like immunoreactions were performed among the ZrO(2) NPs, which were pre-coated on a screen printed electrode (SPE) by electrodeposition, phosphorylated AChE and QD-anti-AChE. The captured QD tags were determined on the SPE by electrochemical stripping analysis of its metallic component (cadmium) after an acid-dissolution step. Paraoxon was used as the model OP insecticide to prepare the phosphorylated AChE adducts to demonstrate proof of principle for the sensor. The phosphorylated AChE adduct was characterized by Fourier transform infrared spectroscopy (FTIR) and mass spectroscopy. The binding affinity of anti-AChE to the phosphorylated AChE was validated with an enzyme-linked immunosorbent assay. The parameters (e.g., amount of ZrO(2) NP, QD-anti-AChE concentration,) that govern the electrochemical response of immunosensors were optimized. The voltammetric response of the immunosensor is highly linear over the range of 10 pM to 4 nM phosphorylated AChE, and the limit of detection is estimated to be 8.0 pM. The immunosensor also successfully detected phosphorylated AChE in human plasma. This new nanoparticle-based electrochemical immunosensor provides an opportunity to develop field-deployable, sensitive, and quantitative biosensors for monitoring exposure to a variety of OP pesticides and nerve agents.


Environmental Health Perspectives | 2007

Electrochemical Sensors for the Detection of Lead and Other Toxic Heavy Metals: The Next Generation of Personal Exposure Biomonitors

Wassana Yantasee; Yuehe Lin; Kitiya Hongsirikarn; Glen E. Fryxell; Raymond S. Addleman; Charles Timchalk

To support the development and implementation of biological monitoring programs, we need quantitative technologies for measuring xenobiotic exposure. Microanalytical based sensors that work with complex biomatrices such as blood, urine, or saliva are being developed and validated and will improve our ability to make definitive associations between chemical exposures and disease. Among toxic metals, lead continues to be one of the most problematic. Despite considerable efforts to identify and eliminate Pb exposure sources, this metal remains a significant health concern, particularly for young children. Ongoing research focuses on the development of portable metal analyzers that have many advantages over current available technologies, thus potentially representing the next generation of toxic metal analyzers. In this article, we highlight the development and validation of two classes of metal analyzers for the voltammetric detection of Pb, including: a) an analyzer based on flow injection analysis and anodic stripping voltammetry at a mercury-film electrode, and b) Hg-free metal analyzers employing adsorptive stripping voltammetry and novel nanostructure materials that include the self-assembled monolayers on mesoporous supports and carbon nanotubes. These sensors have been optimized to detect Pb in urine, blood, and saliva as accurately as the state-of-the-art inductively coupled plasma-mass spectrometry with high reproducibility, and sensitivity allows. These improved and portable analytical sensor platforms will facilitate our ability to conduct biological monitoring programs to understand the relationship between chemical exposure assessment and disease outcomes.


Chemistry: A European Journal | 2008

Nanoparticle-Based Electrochemical Immunosensor for the Detection of Phosphorylated Acetylcholinesterase: An Exposure Biomarker of Organophosphate Pesticides and Nerve AgentsOrganophosphate Pesticides and Nerve Agents

Guodong Liu; Jun Wang; Richard C. Barry; Catherine E. Petersen; Charles Timchalk; Paul L. Gassman; Yuehe Lin

A nanoparticle-based electrochemical immunosensor has been developed for the detection of phosphorylated acetylcholinesterase (AChE), which is a potential biomarker of exposure to organophosphate (OP) pesticides and chemical warfare nerve agents. Zirconia nanoparticles (ZrO(2) NPs) were used as selective sorbents to capture the phosphorylated AChE adduct, and quantum dots (ZnS@CdS, QDs) were used as tags to label monoclonal anti-AChE antibody to quantify the immunorecognition events. The sandwich-like immunoreactions were performed among the ZrO(2) NPs, which were pre-coated on a screen printed electrode (SPE) by electrodeposition, phosphorylated AChE and QD-anti-AChE. The captured QD tags were determined on the SPE by electrochemical stripping analysis of its metallic component (cadmium) after an acid-dissolution step. Paraoxon was used as the model OP insecticide to prepare the phosphorylated AChE adducts to demonstrate proof of principle for the sensor. The phosphorylated AChE adduct was characterized by Fourier transform infrared spectroscopy (FTIR) and mass spectroscopy. The binding affinity of anti-AChE to the phosphorylated AChE was validated with an enzyme-linked immunosorbent assay. The parameters (e.g., amount of ZrO(2) NP, QD-anti-AChE concentration,) that govern the electrochemical response of immunosensors were optimized. The voltammetric response of the immunosensor is highly linear over the range of 10 pM to 4 nM phosphorylated AChE, and the limit of detection is estimated to be 8.0 pM. The immunosensor also successfully detected phosphorylated AChE in human plasma. This new nanoparticle-based electrochemical immunosensor provides an opportunity to develop field-deployable, sensitive, and quantitative biosensors for monitoring exposure to a variety of OP pesticides and nerve agents.


Critical Reviews in Toxicology | 2006

The Acquisition and Application of Absorption, Distribution, Metabolism, and Excretion (ADME) Data in Agricultural Chemical Safety Assessments

Hugh A. Barton; Timothy P. Pastoor; Karl Baetcke; Janice E. Chambers; Janet J. Diliberto; Nancy G. Doerrer; Jeffrey H. Driver; Charles Hastings; Seshadri Iyengar; Robert I. Krieger; Bernhard Stahl; Charles Timchalk

A proposal has been developed by the Agricultural Chemical Safety Assessment (ACSA) Technical Committee of the ILSI Health and Environmental Sciences Institute (HESI) for an improved approach to assessing the safety of crop protection chemicals. The goal is to ensure that studies are scientifically appropriate and necessary without being redundant, and that tests emphasize toxicological endpoints and exposure durations that are relevant for risk assessment. Incorporation of pharmacokinetic studies describing absorption, distribution, metabolism, and excretion is an essential tool for improving the design and interpretation of toxicity studies and their application for safety assessment. A tiered approach is described in which basic pharmacokinetic studies, similar to those for pharmaceuticals, are conducted for regulatory submission. Subsequent tiers provide additional information in an iterative manner, depending on pharmacokinetic properties, toxicity study results, and the intended uses of the compound.


Analytica Chimica Acta | 2008

Detection of Cd, Pb, and Cu in non-pretreated natural waters and urine with thiol functionalized mesoporous silica and Nafion composite electrodes.

Wassana Yantasee; Busarakum Charnhattakorn; Glen E. Fryxell; Yuehe Lin; Charles Timchalk; R. Shane Addleman

Electrochemical sensors have great potential for environmental monitoring of toxic metal ions in waters due to their portability, field-deployability and excellent detection limits. However, electrochemical sensors employing mercury-free approaches typically suffer from binding competition for metal ions and fouling by organic substances and surfactants in natural waters, making sample pretreatments such as wet ashing necessary. In this work, we have developed mercury-free sensors by coating a composite of thiol self-assembled monolayers on mesoporous supports (SH-SAMMS) and Nafion on glassy-carbon electrodes. With the combined benefit of SH-SAMMS as an outstanding metal preconcentrator and Nafion as an antifouling binder, the sensors could detect 0.5 pp b of Pb and 2.5 pp b of Cd in river water, Hanford groundwater, and seawater with a minimal amount of preconcentration time (few minutes) and without any sample pretreatment. The sensor could also detect 2.5 pp b of Cd, Pb, and Cu simultaneously. The electrodes have long service times and excellent single and inter-electrode reproducibility (5% R.S.D. after 8 consecutive measurements). Unlike SAMMS-carbon paste electrodes, the SAMMS-Nafion electrodes were not fouled in samples containing albumin and successfully detected Cd in human urine. Other potentially confounding factors affecting metal detection at SAMMS-Nafion electrodes were studied, including pH effect, transport resistance of metal ions, and detection interference. With the ability to reliably detect low metal concentration ranges without sample pretreatment and fouling, SAMMS-Nafion composite sensors have the potential to become the next-generation metal analyzers for environmental and bio-monitoring of toxic metals.


Analytical Chemistry | 2009

Biomonitoring of organophosphorus agent exposure by reactivation of cholinesterase enzyme based on carbon nanotube-enhanced flow-injection amperometric detection.

Dan Du; Jun Wang; Jordan N. Smith; Charles Timchalk; Yuehe Lin

A portable, rapid, and sensitive assessment of subclinical organophosphorus (OP) agent exposure based on reactivation of cholinesterase (ChE) from OP-inhibited ChE using rat saliva (in vitro) was developed using an electrochemical sensor coupled with a microflow-injection system. The sensor was based on a carbon nanotube (CNT)-modified screen printed carbon electrode (SPE), which was integrated into a flow cell. Because of the extent of interindividual ChE activity variability, ChE biomonitoring often requires an initial baseline determination (noninhibited) of enzyme activity which is then directly compared with activity after OP exposure. This manuscript describes an alternative strategy where reactivation of the phosphorylated enzyme was exploited to enable measurement of both inhibited and baseline ChE activity (after reactivation by an oxime, i.e., pralidoxime iodide) in the same sample. The use of CNT makes the electrochemical detection of the products from enzymatic reactions more feasible with extremely high sensitivity (5% ChE inhibition) and selectivity. Paraoxon was selected as a model OP compound for in vitro inhibition studies. Some experimental parameters, e.g., inhibition and reactivation time, have been optimized such that 92-95% of ChE reactivation can be achieved over a broad range of ChE inhibition (5-94%) with paraoxon. The extent of enzyme inhibition using this electrochemical sensor correlates well with conventional enzyme activity measurements. On the basis of the double determinations of enzyme activity, this flow-injection device has been successfully used to detect paraoxon inhibition efficiency in saliva samples (95% of ChE activity is due to butyrylcholinesterase), which demonstrated its promise as a sensitive monitor of OP exposure in biological fluids. Since it excludes inter- or intraindividual variation in the normal levels of ChE, this new CNT-based electrochemical sensor thus provides a sensitive and quantitative tool for point-of-care assessment and noninvasive biomonitoring of the exposure to OP pesticides and chemical nerve agents.


Toxicological Sciences | 2012

Comparative computational modeling of airflows and vapor dosimetry in the respiratory tracts of rat, monkey, and human

Richard A. Corley; Senthil Kabilan; Andrew P. Kuprat; James P. Carson; Kevin R. Minard; Richard E. Jacob; Charles Timchalk; Robb W. Glenny; Sudhakar Pipavath; Timothy C. Cox; Christopher Wallis; Richard F. Larson; Michelle V. Fanucchi; Edward M. Postlethwait; Daniel R. Einstein

Computational fluid dynamics (CFD) models are useful for predicting site-specific dosimetry of airborne materials in the respiratory tract and elucidating the importance of species differences in anatomy, physiology, and breathing patterns. We improved the imaging and model development methods to the point where CFD models for the rat, monkey, and human now encompass airways from the nose or mouth to the lung. A total of 1272, 2172, and 135 pulmonary airways representing 17±7, 19±9, or 9±2 airway generations were included in the rat, monkey and human models, respectively. A CFD/physiologically based pharmacokinetic model previously developed for acrolein was adapted for these anatomically correct extended airway models. Model parameters were obtained from the literature or measured directly. Airflow and acrolein uptake patterns were determined under steady-state inhalation conditions to provide direct comparisons with prior data and nasal-only simulations. Results confirmed that regional uptake was sensitive to airway geometry, airflow rates, acrolein concentrations, air:tissue partition coefficients, tissue thickness, and the maximum rate of metabolism. Nasal extraction efficiencies were predicted to be greatest in the rat, followed by the monkey, and then the human. For both nasal and oral breathing modes in humans, higher uptake rates were predicted for lower tracheobronchial tissues than either the rat or monkey. These extended airway models provide a unique foundation for comparing material transport and site-specific tissue uptake across a significantly greater range of conducting airways in the rat, monkey, and human than prior CFD models.

Collaboration


Dive into the Charles Timchalk's collaboration.

Top Co-Authors

Avatar

Yuehe Lin

Washington State University

View shared research outputs
Top Co-Authors

Avatar

Jordan N. Smith

Pacific Northwest National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Torka S. Poet

Pacific Northwest National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Wassana Yantasee

Battelle Memorial Institute

View shared research outputs
Top Co-Authors

Avatar

Glen E. Fryxell

Battelle Memorial Institute

View shared research outputs
Top Co-Authors

Avatar

Jun Wang

Pacific Northwest National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Dan Du

Washington State University

View shared research outputs
Top Co-Authors

Avatar

Karla D. Thrall

Pacific Northwest National Laboratory

View shared research outputs
Top Co-Authors

Avatar

R. Shane Addleman

Pacific Northwest National Laboratory

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge