H.-D. Nuhn
Stanford University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by H.-D. Nuhn.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 1996
R. Tatchyn; J. Arthur; M. Baltay; K. Bane; R. Boyce; M. Cornacchia; T Cremer; A. Fisher; S.-J. Hahn; M. Hernandez; G. Loew; R. H. Miller; W.R. Nelson; H.-D. Nuhn; J.M. Paterson; T. Raubenheimer; J.N Weaver; Helmut Wiedemann; Herman Winick; C. Pellegrini; G. Travish; E.T. Scharlemann; S. Caspi; William M. Fawley; Klaus Halbach; Kwang-Je Kim; R. Schlueter; Ming Xie; D. D. Meyerhofer; R. Bonifacio
Abstract In recent years significant studies have been initiated on the feasibility of utilizing a portion of the 3 km S-band accelerator at SLAC to drive a short wavelength (4.5−1.5 A) Linac Coherent Light Source (LCLS), a Free-Electron Laser (FEL) operating in the Self-Amplified Spontaneous Emission (SASE) regime. Electron beam requirements for single-pass saturation in a minimal time include: 1) a peak current in the 7 kA range, 2) a relative energy spread of e = λ 4π , where λ[m] is the output wavelength. Requirements on the insertion device include field error levels of 0.02% for keeping the electron bunch centered on and in phase with the amplified photons, and a focusing beta of 8 m/rad for inhibiting the dilution of its transverse density. Although much progress has been made in developing individual components and beam-processing techniques necessary for LCLS operation down to ∼20 A, a substantial amount of research and development is still required in a number of theoretical and experimental areas leading to the construction and operation of a 4.5−1.5 A LCLS. In this paper we report on a research and development program underway and in planning at SLAC for addressing critical questions in these areas. These include the construction and operation of a linac test stand for developing laser-driven photocathode rf guns with normalized emittances approaching 1 mm-mrad; development of advanced beam compression, stability, and emittance control techniques at multi-GeV energies; the construction and operation of a FEL Amplifier Test Experiment (FATE) for theoretical and experimental studies of SASE at IR wavelengths; an undulator development program to investigate superconducting, hybrid/permanent magnet (hybrid/PM), and pulsed-Cu technologies; theoretical and computational studies of high-gain FEL physics and LCLS component designs; development of X-ray optics and instrumentation for extracting, modulating, and delivering photons to experimental users; and the study and development of scientific experiments made possible by the source properties of the LCLS.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2002
M. Borland; Y.-C. Chae; P. Emma; John W. Lewellen; V. Bharadwaj; William M. Fawley; P. Krejcik; C. Limborg; S.V. Milton; H.-D. Nuhn; R. Soliday; M. Woodley
Abstract It is widely appreciated that the performance of self-amplified spontaneous emission free-electron lasers (FELs) depends critically on the properties of the drive beam. In view of this, a multi-laboratory collaboration has explored methods and software tools for integrated simulation of the photoinjector, linear accelerator, bunch compressor, and FEL. Rather than create a single code to handle such a system, our goal has been a robust, generic solution wherein pre-existing simulation codes are used sequentially. We have standardized on the use of Argonne National Laboratorys Self-Describing Data Sets file protocol for transfer of data among codes. The simulation codes used are PARMELA, elegant , and GENESIS. We describe the software methodology and its advantages, then provide examples involving Argonnes Low-Energy Undulator Test Line and Stanford Linear Accelerator Centers Linac Coherent Light Source. We also indicate possible future direction of this work.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 1993
C. Pellegrini; J. B. Rosenzweig; H.-D. Nuhn; P. Pianetta; R. Tatchyn; Herman Winick; K. Bane; P. Morton; T. Raubenheimer; J. T. Seeman; Klaus Halbach; Kwang-Je Kim; Janos Kirz
Abstract We report the results of preliminary studies of a 2 to 4 nm SASE FEL, using a photoinjector to produce the electron beam, and the SLAC linac to accelerate it to an energy up to 10 GeV. Longitudinal bunch compression is used to increase ten fold the peak current to 2.5 kA, while reducing the bunch length to the subpicosecond range. The saturated output power is in the multi-gigawatt range, producing about 1014 coherent photons within a bandwidth of about 0.2% rms, in a pulse of several millijoules. At 120 Hz repetition rate the average power is about 1 W. The system is optimized for X-ray microscopy in the water window around 2 to 4 nm, and will permit imaging a biological sample in a single subpicosecond pulse.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 1994
C. Pellegrini; J. B. Rosenzweig; G. Travish; K. Bane; R. Boyce; G. Loew; P. Morton; H.-D. Nuhn; J.M. Paterson; P. Pianetta; T. Raubenheimer; J. Seeman; R. Tatchyn; V. Vylet; Herman Winick; K. Halbach; K.-J. Kim; M. Xie; D. Prosnitz; E.T. Scharlemann; R. Bonifacio; L. De Salvo; P. Pierini
We discuss the design and performance of a 2 to 4 nm FEL operating in Self-Amplified Spontaneous Emission (SASE), using a photoinjector to produce the electron beam, and the SLAC linac to accelerate it to an energy of about 7 GeV. Longitudinal bunch compression is used to increase the peak current to 2.5 kA, while reducing the bunch length to about 40 μm. The FEL field gain length is about 6 m, and the saturation length is about 60 m. The saturated output power is about 10 GW, corresponding to about 1014 photons in a single pulse in a bandwidth of about 0.1%, with a pulse duration of 0.16 ps. Length compression, emittance control, phase stability, FEL design criteria, and parameter tolerances are discussed.
international conference on particle accelerators | 1993
R. Tatchyn; R. Boyce; K. Halbach; H.-D. Nuhn; J. Seeman; Herman Winick; C. Pellegrini
In this paper we describe design, fabrication, and measurement aspects of a pure permanent magnet (PM) insertion device designed to operate as an FEL at a 1st harmonic energy of 300 eV and an electron energy of 7 GeV in the self-amplified spontaneous emission regime.<<ETX>>
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2000
S. G. Biedron; Y.-C. Chae; Roger J. Dejus; B. Faatz; H.P. Freund; S.V. Milton; H.-D. Nuhn; S. Reiche
A self-amplified spontaneous emission (SASE) free-electron laser (FEL) is under construction at the Advanced Photon Source (APS). Five FEL simulation codes were used in the design phase: GENESIS, GINGER, MEDUSA, RON, and TDA3D. Initial comparisons between each of these independent formulations show good agreement for the parameters of the APS SASE FEL.
Review of Scientific Instruments | 2016
Daniel Higley; Konstantin Hirsch; Georgi L. Dakovski; Emmanuelle Jal; Edwin Yuan; TianMin Liu; Alberto Lutman; James P. MacArthur; Elke Arenholz; Zhao Chen; G. Coslovich; Peter Denes; Patrick Granitzka; P. Hart; Matthias C. Hoffmann; John Joseph; Loic Le Guyader; Ankush Mitra; Stefan Moeller; Hendrik Ohldag; Matthew D. Seaberg; Padraic Shafer; J. Stöhr; A. Tsukamoto; H.-D. Nuhn; A. H. Reid; Hermann A. Dürr; W. F. Schlotter
X-ray magnetic circular dichroism spectroscopy using an X-ray free electron laser is demonstrated with spectra over the Fe L(3,2)-edges. The high brightness of the X-ray free electron laser combined with high accuracy detection of incident and transmitted X-rays enables ultrafast X-ray magnetic circular dichroism studies of unprecedented sensitivity. This new capability is applied to a study of all-optical magnetic switching dynamics of Fe and Gd magnetic sublattices in a GdFeCo thin film above its magnetization compensation temperature.
Journal of Synchrotron Radiation | 2004
M. Cornacchia; J. Arthur; K. Bane; Bolton P; Roger Carr; Decker Fj; P. Emma; Galayda J; Jerome Hastings; Keith O. Hodgson; Huang Z; I. Lindau; H.-D. Nuhn; J.M. Paterson; C. Pellegrini; S. Reiche; Schlarb H; J. Stöhr; Gennady Stupakov; Walz D; Herman Winick
A study of the potential for the development of the Linac Coherent Light Source (LCLS) beyond the specifications of the baseline design is presented. These future developments include delivery of X-ray pulses in the 1 fs regime, extension of the spectral range, increase of the FEL power, exploitation of the spontaneous emission, and a more flexible time structure. As this potential is exploited, the LCLS can maintain its role as a world-leading instrument for many years beyond its commissioning in 2008 and initial operation as the worlds first X-ray free-electron laser.
international free electron laser conference | 2002
S. G. Biedron; Zhirong Huang; Kwang-Je Kim; S.V. Milton; G. Dattoli; P. L. Ottaviani; A. Renieri; William M. Fawley; H.P. Freund; H.-D. Nuhn
The generation of harmonics through a nonlinear mechanism driven by bunching at the fundamental has sparked interest as a path toward enhancing and extending the usefulness of an x-ray free-electron laser (FEL) facility. The sensitivity of the nonlinear harmonic generation to undulator imperfections, electron beam energy spread, peak current, and emittance is important in an evaluation of the process. Typically, linear instabilities in FELs are characterized by increased sensitivity to both electron beam and undulator quality with increasing harmonic number. However, since the nonlinear harmonic generation mechanism is driven by the growth of the fundamental, the sensitivity of the nonlinear harmonic mechanism is not expected to be significantly greater than that of the fundamental. In this paper, they study the effects of electron beam quality, more specifically, emittance, energy spread, and peak current, on the nonlinear harmonics in a 1.5-{angstrom} FEL, and show that the decline in the harmonic emission roughly follows that of the fundamental.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2001
E. Gluskin; N.A. Vinokurov; G. Decker; Roger J. Dejus; P. Emma; P. Ilinski; E. R. Moog; H.-D. Nuhn; I. Vasserman
The Linac Coherent Light Source (LCLS) undulator line will consist of undulator segments separated by breaks of various lengths. Focusing quadrupoles, in a FODO lattice, and electron-beam diagnostics will be located in the breaks, and every third break will be longer to also accommodate photon diagnostics. The electron-beam beta function and the undulator period were selected to minimize the saturation length. The FEL simulation code RON has been used to optimize parameters such as the length of the undulators and the break lengths between undulators. Different break lengths after the first three undulators have been found to help reduce the overall undulator line saturation length. Tolerances for individual undulators have also been determined. r 2001 Elsevier Science B.V. All rights reserved. PACS: 41.60. Cr