Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Harsha Radhakrishnan is active.

Publication


Featured researches published by Harsha Radhakrishnan.


Optics Letters | 2010

Rapid volumetric angiography of cortical microvasculature with optical coherence tomography

Vivek J. Srinivasan; James Jiang; Mohammed A. Yaseen; Harsha Radhakrishnan; Weicheng Wu; Scott Barry; Alex Cable; David A. Boas

We describe methods and algorithms for rapid volumetric imaging of cortical vasculature with optical coherence tomography (OCT). By optimizing system design, scanning protocols, and algorithms for visualization of capillary flow, comprehensive imaging of the surface pial vasculature and capillary bed is performed in approximately 12 s. By imaging during hypercapnia and comparing with simultaneous CCD imaging, the sources of contrast of OCT angiography are investigated.


Optics Express | 2012

Optical coherence microscopy for deep tissue imaging of the cerebral cortex with intrinsic contrast

Vivek J. Srinivasan; Harsha Radhakrishnan; James Jiang; Scott Barry; Alex Cable

In vivo optical microscopic imaging techniques have recently emerged as important tools for the study of neurobiological development and pathophysiology. In particular, two-photon microscopy has proved to be a robust and highly flexible method for in vivo imaging in highly scattering tissue. However, two-photon imaging typically requires extrinsic dyes or contrast agents, and imaging depths are limited to a few hundred microns. Here we demonstrate Optical Coherence Microscopy (OCM) for in vivo imaging of neuronal cell bodies and cortical myelination up to depths of ~1.3 mm in the rat neocortex. Imaging does not require the administration of exogenous dyes or contrast agents, and is achieved through intrinsic scattering contrast and image processing alone. Furthermore, using OCM we demonstrate in vivo, quantitative measurements of optical properties (index of refraction and attenuation coefficient) in the cortex, and correlate these properties with laminar cellular architecture determined from the images. Lastly, we show that OCM enables direct visualization of cellular changes during cell depolarization and may therefore provide novel optical markers of cell viability.


Biomedical Optics Express | 2012

OCT methods for capillary velocimetry

Vivek J. Srinivasan; Harsha Radhakrishnan; Eng H. Lo; Emiri T. Mandeville; James Jiang; Scott Barry; Alex Cable

To date, two main categories of OCT techniques have been described for imaging hemodynamics: Doppler OCT and OCT angiography. Doppler OCT can measure axial velocity profiles and flow in arteries and veins, while OCT angiography can determine vascular morphology, tone, and presence or absence of red blood cell (RBC) perfusion. However, neither method can quantify RBC velocity in capillaries, where RBC flow is typically transverse to the probe beam and single-file. Here, we describe new methods that potentially address these limitations. Firstly, we describe a complex-valued OCT signal in terms of a static scattering component, dynamic scattering component, and noise. Secondly, we propose that the time scale of random fluctuations in the dynamic scattering component are related to red blood cell velocity. Analysis was performed along the slow axis of repeated B-scans to parallelize measurements. We correlate our purported velocity measurements against two-photon microscopy measurements of RBC velocity, and investigate changes during hypercapnia. Finally, we image the ischemic stroke penumbra during distal middle cerebral artery occlusion (dMCAO), where OCT velocimetry methods provide additional insight that is not afforded by either Doppler OCT or OCT angiography.


Journal of Cerebral Blood Flow and Metabolism | 2011

Optical coherence tomography for the quantitative study of cerebrovascular physiology

Vivek J. Srinivasan; Dmitriy N. Atochin; Harsha Radhakrishnan; James Jiang; Svetlana Ruvinskaya; Weicheng Wu; Scott Barry; Alex Cable; Cenk Ayata; Paul L. Huang; David A. Boas

Doppler optical coherence tomography (DOCT) and OCT angiography are novel methods to investigate cerebrovascular physiology. In the rodent cortex, DOCT flow displays features characteristic of cerebral blood flow, including conservation along nonbranching vascular segments and at branch points. Moreover, DOCT flow values correlate with hydrogen clearance flow values when both are measured simultaneously. These data validate DOCT as a noninvasive quantitative method to measure tissue perfusion over a physiologic range.


Optics Express | 2011

Motion correction for phase-resolved dynamic optical coherence tomography imaging of rodent cerebral cortex

Jonghwan Lee; Vivek J. Srinivasan; Harsha Radhakrishnan; David A. Boas

Cardiac and respiratory motions in animals are the primary source of image quality degradation in dynamic imaging studies, especially when using phase-resolved imaging modalities such as spectral-domain optical coherence tomography (SD-OCT), whose phase signal is very sensitive to movements of the sample. This study demonstrates a method with which to compensate for motion artifacts in dynamic SD-OCT imaging of the rodent cerebral cortex. We observed that respiratory and cardiac motions mainly caused, respectively, bulk image shifts (BISs) and global phase fluctuations (GPFs). A cross-correlation maximization-based shift correction algorithm was effective in suppressing BISs, while GPFs were significantly reduced by removing axial and lateral global phase variations. In addition, a non-origin-centered GPF correction algorithm was examined. Several combinations of these algorithms were tested to find an optimized approach that improved image stability from 0.5 to 0.8 in terms of the cross-correlation over 4 s of dynamic imaging, and reduced phase noise by two orders of magnitude in ~8% voxels.


NeuroImage | 2014

Somatosensory evoked changes in cerebral oxygen consumption measured non-invasively in premature neonates

Nadege Roche-Labarbe; Angela Fenoglio; Harsha Radhakrishnan; Marcia Kocienski-Filip; Stefan A. Carp; Jay Dubb; David A. Boas; P. Ellen Grant; Maria Angela Franceschini

The hemodynamic functional response is used as a reliable marker of neuronal activity in countless studies of brain function and cognition. In newborns and infants, however, conflicting results have appeared in the literature concerning the typical response, and there is little information on brain metabolism and functional activation. Measurement of all hemodynamic components and oxygen metabolism is critical for understanding neurovascular coupling in the developing brain. To this end, we combined multiple near infrared spectroscopy techniques to measure oxy- and deoxy-hemoglobin concentrations, cerebral blood volume (CBV), and relative cerebral blood flow (CBF) in the somatosensory cortex of 6 preterm neonates during passive tactile stimulation of the hand. By combining these measures we estimated relative changes in the cerebral metabolic rate of oxygen consumption (rCMRO2). CBF starts increasing immediately after stimulus onset, and returns to baseline before blood volume. This is consistent with the model of pre-capillary arteriole active dilation driving the CBF response, with a subsequent CBV increase influenced by capillaries and veins dilating passively to accommodate the extra blood. rCMRO2 estimated using the steady-state formulation shows a biphasic pattern: an increase immediately after stimulus onset, followed by a post-stimulus undershoot due to blood flow returning faster to baseline than oxygenation. However, assuming a longer mean transit time from the arterial to the venous compartment, due to the immature vascular system of premature infants, reduces the post-stimulus undershoot and increases the flow/consumption ratio to values closer to adult values reported in the literature. We are the first to report changes in local rCBF and rCMRO2 during functional activation in preterm infants. The ability to measure these variables in addition to hemoglobin concentration changes is critical for understanding neurovascular coupling in the developing brain, and for using this coupling as a reliable functional imaging marker in neonates.


Journal of Cerebral Blood Flow and Metabolism | 2011

Microvascular oxygen tension and flow measurements in rodent cerebral cortex during baseline conditions and functional activation.

Mohammad A. Yaseen; Vivek J. Srinivasan; Sava Sakadžić; Harsha Radhakrishnan; Iwona Gorczynska; Weicheng Wu; James G. Fujimoto; David A. Boas

Measuring cerebral oxygen delivery and metabolism microscopically is important for interpreting macroscopic functional magnetic resonance imaging (fMRI) data and identifying pathological changes associated with stroke, Alzheimers disease, and brain injury. Here, we present simultaneous, microscopic measurements of cerebral blood flow (CBF) and oxygen partial pressure (pO2) in cortical microvessels of anesthetized rats under baseline conditions and during somatosensory stimulation. Using a custom-built imaging system, we measured CBF with Fourier-domain optical coherence tomography (OCT), and vascular pO2 with confocal phosphorescence lifetime microscopy. Cerebral blood flow and pO2 measurements displayed heterogeneity over distances irresolvable with fMRI and positron emission tomography. Baseline measurements indicate O2 extraction from pial arterioles and homogeneity of ascending venule pO2 despite large variation in microvessel flows. Oxygen extraction is linearly related to flow in ascending venules, suggesting that flow in ascending venules closely matches oxygen demand of the drained territory. Oxygen partial pressure and relative CBF transients during somatosensory stimulation further indicate arteriolar O2 extraction and suggest that arterioles contribute to the fMRI blood oxygen level dependent response. Understanding O2 supply on a microscopic level will yield better insight into brain function and the underlying mechanisms of various neuropathologies.


NeuroImage | 2009

Study of neurovascular coupling in humans via simultaneous magnetoencephalography and diffuse optical imaging acquisition

Wanmei Ou; Ilkka Nissilä; Harsha Radhakrishnan; David A. Boas; Matti Hämäläinen; Maria Angela Franceschini

By combining diffuse optical imaging (DOI) and magnetoencephalography (MEG) we investigate neurovascular coupling non-invasively in human subjects using median-nerve stimulation. Previous fMRI studies have shown a habituation effect in the hemodynamic blood oxygen level-dependent (BOLD) response for stimulation periods longer than 2 s. With DOI and MEG we can test whether this effect in hemodynamic response can be accounted for by a habituation effect in the neural response. Our experimental results show that the habituation effect in the hemodynamic response is stronger than that in the earliest cortical neural response (N20). Using a linear convolution model to predict hemodynamic responses we found that including late neural components (> or = 30 ms) improves the prediction of the hemoglobin response. This finding suggests that in addition to the initial evoked-response deflections related to the talamic afferent input, later cortical activity is needed to predict the hemodynamic response.


Biomedical Optics Express | 2015

Quantitative microvascular hemoglobin mapping using visible light spectroscopic Optical Coherence Tomography

Shau Poh Chong; Conrad W. Merkle; Conor Leahy; Harsha Radhakrishnan; Vivek J. Srinivasan

Quantification of chromophore concentrations in reflectance mode remains a major challenge for biomedical optics. Spectroscopic Optical Coherence Tomography (SOCT) provides depth-resolved spectroscopic information necessary for quantitative analysis of chromophores, like hemoglobin, but conventional SOCT analysis methods are applicable only to well-defined specular reflections, which may be absent in highly scattering biological tissue. Here, by fitting of the dynamic scattering signal spectrum in the OCT angiogram using a forward model of light propagation, we quantitatively determine hemoglobin concentrations directly. Importantly, this methodology enables mapping of both oxygen saturation and total hemoglobin concentration, or alternatively, oxyhemoglobin and deoxyhemoglobin concentration, simultaneously. Quantification was verified by ex vivo blood measurements at various pO2 and hematocrit levels. Imaging results from the rodent brain and retina are presented. Confounds including noise and scattering, as well as potential clinical applications, are discussed.


PLOS ONE | 2013

Multiparametric, Longitudinal Optical Coherence Tomography Imaging Reveals Acute Injury and Chronic Recovery in Experimental Ischemic Stroke

Vivek J. Srinivasan; Emiri T. Mandeville; Anil Can; Francesco Blasi; Mihail Climov; Ali Daneshmand; Jeong Hyun Lee; Esther Yu; Harsha Radhakrishnan; Eng H. Lo; Sava Sakadžić; Katharina Eikermann-Haerter; Cenk Ayata

Progress in experimental stroke and translational medicine could be accelerated by high-resolution in vivo imaging of disease progression in the mouse cortex. Here, we introduce optical microscopic methods that monitor brain injury progression using intrinsic optical scattering properties of cortical tissue. A multi-parametric Optical Coherence Tomography (OCT) platform for longitudinal imaging of ischemic stroke in mice, through thinned-skull, reinforced cranial window surgical preparations, is described. In the acute stages, the spatiotemporal interplay between hemodynamics and cell viability, a key determinant of pathogenesis, was imaged. In acute stroke, microscopic biomarkers for eventual infarction, including capillary non-perfusion, cerebral blood flow deficiency, altered cellular scattering, and impaired autoregulation of cerebral blood flow, were quantified and correlated with histology. Additionally, longitudinal microscopy revealed remodeling and flow recovery after one week of chronic stroke. Intrinsic scattering properties serve as reporters of acute cellular and vascular injury and recovery in experimental stroke. Multi-parametric OCT represents a robust in vivo imaging platform to comprehensively investigate these properties.

Collaboration


Dive into the Harsha Radhakrishnan's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Conor Leahy

University of California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Shau Poh Chong

University of California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge