Judith A. Roether
University of Erlangen-Nuremberg
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Judith A. Roether.
Biomaterials | 2002
Judith A. Roether; Aldo R. Boccaccini; Larry L. Hench; Véronique Maquet; Sandrine Gautier; Robert Jérôme
Bioactive and bioresorbable composite materials were fabricated using macroporous poly(DL-lactide) (PDLLA) foams coated with and impregnated by bioactive glass (Bioglass) particles. Stable and homogeneous Bioglass coatings on the surface of PDLLA foams as well as infiltration of Bioglass particles throughout the porous network were achieved using a slurry-dipping technique in conjunction with pre-treatment of the foams in ethanol. The quality of the bioactive glass coatings was reproducible in terms of thickness and microstructure. Additionally, electrophoretic deposition was investigated as an alternative method for the fabrication of PDLLA foam/Bioglass composite materials. In vitro studies in simulated body fluid (SBF) were performed to study the formation of hydroxyapatite (HA) on the surface of PDLLA/Bioglass composites. SEM analysis showed that the HA layer thickness rapidly increased with increasing time in SBF. The high bioactivity of the PDLLA foam/Bioglass composites indicates the potential of the materials for use as bioactive, resorbable scaffolds in bone tissue engineering.
Journal of Biomedical Materials Research Part B | 2010
Kah Ling Low; Soon Huat Tan; Sharif Hussein Sharif Zein; Judith A. Roether; Viviana Mouriño; Aldo R. Boccaccini
A major weakness of current orthopedic implant materials, for instance sintered hydroxyapatite (HA), is that they exist as a hardened form, requiring the surgeon to fit the surgical site around an implant to the desired shape. This can cause an increase in bone loss, trauma to the surrounding tissue, and longer surgical time. A convenient alternative to harden bone filling materials are injectable bone substitutes (IBS). In this article, recent progress in the development and application of calcium phosphate (CP)-based composites use as IBS is reviewed. CP materials have been used widely for bone replacement because of their similarity to the mineral component of bone. The main limitation of bulk CP materials is their brittle nature and poor mechanical properties. There is significant effort to reinforce or improve the mechanical properties and injectability of calcium phosphate cement (CPC) and this review resumes different alternatives presented in this specialized literature.
Journal of Materials Science: Materials in Medicine | 2002
Judith A. Roether; Julie E. Gough; Aldo R. Boccaccini; Larry L. Hench; Véronique Maquet; Robert Jérôme
Bioresorbable and bioactive tissue engineering scaffolds based on bioactive glass (45S5 Bioglass®) particles and macroporous poly(DL-lactide) (PDLLA) foams were fabricated. A slurry dipping technique in conjunction with pretreatment in ethanol was used to achieve reproducible and well adhering bioactive glass coatings of uniform thickness on the internal and external surfaces of the foams. In vitro studies in simulated body fluid (SBF) demonstrated rapid hydroxyapatite (HA) formation on the surface of the composites, indicating their bioactivity. For comparison, composite foams containing Bioglass® particles as filler for the polymer matrix (in concentration of up to 40 wt %) were prepared by freeze-drying, enabling homogenous glass particle distribution in the polymer matrix. The formation of HA on the composite surfaces after immersion in phosphate buffer saline (PBS) was investigated to confirm the bioactivity of the composites. Human osteoblasts (HOBs) were seeded onto as-fabricated PDLLA foams and onto PDLLA foams coated with Bioglass® particles to determine early cell attachment and spreading. Cells were observed to attach and spread on all surfaces after the first 90 min in culture. The results of this study indicate that the fabricated composite materials have potential as scaffolds for guided bone regeneration.
Acta Biomaterialia | 2012
M. Erol; V. Mouriňo; Phillipa J. Newby; Xanthippi Chatzistavrou; Judith A. Roether; Leena Hupa; Aldo R. Boccaccini
The aim of this study was to synthesize and characterize new boron-containing bioactive glass-based scaffolds coated with alginate cross-linked with copper ions. A recently developed bioactive glass powder with nominal composition (wt.%) 65 SiO2, 15 CaO, 18.4 Na2O, 0.1 MgO and 1.5 B2O3 was fabricated as porous scaffolds by the foam replica method. Scaffolds were alginate coated by dipping them in alginate solution. Scanning electron microscopy investigations indicated that the alginate effectively attached on the surface of the three-dimensional scaffolds leading to a homogeneous coating. It was confirmed that the scaffold structure remained amorphous after the sintering process and that the alginate coating improved the scaffold bioactivity and mechanical properties. Copper release studies showed that the alginate-coated scaffolds allowed controlled release of copper ions. The novel copper-releasing composite scaffolds represent promising candidates for bone regeneration.
PLOS ONE | 2014
Bapi Sarker; Raminder Singh; Raquel Silva; Judith A. Roether; Joachim Kaschta; Rainer Detsch; Dirk W. Schubert; Iwona Cicha; Aldo R. Boccaccini
Due to the relatively poor cell-material interaction of alginate hydrogel, alginate-gelatin crosslinked (ADA-GEL) hydrogel was synthesized through covalent crosslinking of alginate di-aldehyde (ADA) with gelatin that supported cell attachment, spreading and proliferation. This study highlights the evaluation of the physico-chemical properties of synthesized ADA-GEL hydrogels of different compositions compared to alginate in the form of films. Moreover, in vitro cell-material interaction on ADA-GEL hydrogels of different compositions compared to alginate was investigated by using normal human dermal fibroblasts. Viability, attachment, spreading and proliferation of fibroblasts were significantly increased on ADA-GEL hydrogels compared to alginate. Moreover, in vitro cytocompatibility of ADA-GEL hydrogels was found to be increased with increasing gelatin content. These findings indicate that ADA-GEL hydrogel is a promising material for the biomedical applications in tissue-engineering and regeneration.
Expert Opinion on Drug Delivery | 2013
Viviana Mouriño; Juan Pablo Cattalini; Judith A. Roether; Prachi Dubey; Ipsita Roy; Aldo R. Boccaccini
Introduction: Next-generation scaffolds for bone tissue engineering (BTE) should exhibit the appropriate combination of mechanical support and morphological guidance for cell proliferation and attachment while at the same time serving as matrices for sustained delivery of therapeutic drugs and/or biomolecular signals, such as growth factors. Drug delivery from BTE scaffolds to induce the formation of functional tissues, which may need to vary temporally and spatially, represents a versatile approach to manipulating the local environment for directing cell function and/or to treat common bone diseases or local infection. In addition, drug delivery from BTE is proposed to either increase the expression of tissue inductive factors or to block the expression of others factors that could inhibit bone tissue formation. Composite scaffolds which combine biopolymers and bioactive ceramics in mechanically competent 3D structures, including also organic–inorganic hybrids, are being widely developed for BTE, where the affinity and interaction between biomaterials and therapeutic drugs or biomolecular signals play a decisive role in controlling the release rate. Areas covered: This review covers current developments and applications of 3D composite scaffolds for BTE which exhibit the added capability of controlled delivery of therapeutic drugs or growth factors. A summary of drugs and biomolecules incorporated in composite scaffolds and approaches developed to combine biopolymers and bioceramics in composites for drug delivery systems for BTE is presented. Special attention is given to identify the main challenges and unmet needs of current designs and technologies for developing such multifunctional 3D composite scaffolds for BTE. Expert opinion: One of the major challenges for developing composite scaffolds for BTE is the incorporation of a drug delivery function of sufficient complexity to be able to induce the release patterns that may be necessary for effective osseointegration, vascularization and bone regeneration. Loading 3D scaffolds with different biomolecular agents should produce a codelivery system with different, predetermined release profiles. It is also envisaged that the number of relevant bioactive agents that can be loaded onto scaffolds will be increased, whilst the composite scaffold design should exploit synergistically the different degradation profiles of the organic and inorganic components.
Expert Review of Medical Devices | 2015
Anahí Philippart; Aldo R. Boccaccini; Claudia Fleck; Dirk W. Schubert; Judith A. Roether
Inorganic scaffolds with high interconnected porosity based on bioactive glasses and ceramics are prime candidates for applications in bone tissue engineering. These materials however exhibit relatively low fracture strength and high brittleness. A simple and effective approach to improve the toughness is to combine the basic scaffold structure with polymer coatings or through the formation of interpenetrating polymer-bioactive ceramic microstructures. The polymeric phase can additionally serve as a carrier for growth factors and therapeutic drugs, thus adding biological functionalities. The present paper reviews the state-of-the art in the field of polymer coated and infiltrated bioactive inorganic scaffolds. Based on the notable combination of bioactivity, improved mechanical properties and drug or growth factor delivery capability, this scaffold type is a candidate for bone and osteochondral regeneration strategies. Remaining challenges for the improvement of the materials are discussed and opportunities to broaden the application potential of this scaffold type are also highlighted.
Biomedical Materials | 2009
Ewelina Zawadzak; Monika Bil; Joanna Ryszkowska; Showan N. Nazhat; Johann Cho; Oana Anca Bretcanu; Judith A. Roether; Aldo R. Boccaccini
Carbon nanotubes (CNTs) were deposited on the surfaces of polyurethane (PUR) foams by electrophoretic deposition (EPD). The parameters of EPD were optimized in order to obtain homogeneous CNT coatings on PUR foams and adequate infiltration of the three-dimensional (3D) porous network. The microstructure of the composites was investigated by high-resolution scanning electron microscopy (HRSEM), revealing that optimal quality of the coatings was achieved by an EPD voltage of 20 V. The thermal properties of the CNT-coated specimens, determined by thermogravimetric analysis (TGA), were correlated to the foam microstructure. In vitro tests in concentrated simulated body fluid (1.5 SBF) were performed to study the influence of the presence of CNTs on the bioactivity of PUR-based scaffolds, assessed by the formation of calcium phosphate (CaP) compounds, e.g. hydroxyapatite (HA), on the foam surfaces. It was observed that CNTs accelerate the precipitation of CaP, which is thought to be due to the presence of more nucleation centres for crystal nucleation and growth, as compared with uncoated foams. Polyurethane foams with CNT coating have the potential to be used as bioactive scaffolds in bone tissue engineering due to their high interconnected porosity, bioactivity and nanostructured surface topography.
Materials Science and Engineering: C | 2013
Ranjana Rai; Marwa Tallawi; Niccoletta Barbani; Caterina Frati; Denise Madeddu; Stefano Cavalli; Gallia Graiani; Federico Quaini; Judith A. Roether; Dirk W. Schubert; Elisabetta Rosellini; Aldo R. Boccaccini
In this study biomimetic poly(glycerol sebacate) PGS matrix was developed for cardiac patch application. The rationale was that such matrices would provide conducive environment for the seeded cells at the interphase with PGS. From the microstructural standpoint, PGS was fabricated into dense films and porous PGS scaffolds. From the biological aspect, biomimetic PGS membranes were developed via covalently binding peptides Tyr-Ile-Gly-Ser-Arg (YIGSR) and Gly-Arg-Gly-Asp-Ser-Pro (GRGDSP), corresponding to the epitope sequences of laminin and fibronectin, respectively onto the surface. To improve and enhance homogenous binding of peptides onto the PGS surface, chemical modification of its surface was carried out. A sequential regime of alkaline hydrolysis with 0.01 M NaOH for 5 min and acidification with 0.01 M HCl for 25s was optimal. More COOH chemical group was exposed without causing deleterious effect on the bulk properties of the polymer as revealed by the physicochemical analysis carried out. HPLC analysis, chemical imaging and ToF-SIMS were able to establish the successful homogenous functionalization of PGS membranes with the peptides. Finally, the developed biomimetic membranes supported the adhesion and growth of rat and human cardiac progenitor cells.
Biomedical Materials | 2007
Monika Bil; Joanna Ryszkowska; Judith A. Roether; Oana Anca Bretcanu; Aldo R. Boccaccini
Polyurethane (PUR) and polyurethane/poly(d, l-lactide) acid (PUR/PDLLA) based scaffolds coated with Bioglass particles for application in bone tissue engineering were fabricated. The slurry-dipping method was used for coating preparation. The homogeneous structure of the Bioglass coatings on the surface of the PUR and PUR/PDLLA foams indicated a good adhesion of the bioactive glass particles to polyurethane without any additional surface treatment. In vitro studies in simulated body fluid (SBF) were performed to study the influence of Bioglass coating on biodegrability and bioactivity of PUR-based scaffolds. The surface of Bioglass-coated samples was covered by a layer of carbonate-containing apatite after 7 days of immersion in SBF, while in uncoated polymer samples apatite crystals were not detected even after 21 days of immersion in SBF. The apatite layer was characterized by scanning electron microscopy (SEM), EDS analysis and attenuated total reflectance-Fourier transform infrared spectrometry (FTIR-ATR). Weight loss measurements showed that the in vitro degradation rate of the composite scaffolds in SBF was higher in comparison to uncoated polyurethane samples. PUR and PUR/PDLLA foams with Bioglass coating have potential to be used as bioactive, biodegradable scaffolds in bone tissue engineering.