Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where M. Tartaglia is active.

Publication


Featured researches published by M. Tartaglia.


IEEE Transactions on Applied Superconductivity | 2005

R&D of Nb/sub 3/Sn accelerator magnets at Fermilab

A.V. Zlobin; G. Ambrosio; N. Andreev; E. Barzi; B. Bordini; R. Bossert; R. Carcagno; D.R. Chichili; J. DiMarco; L. Elementi; S. Feher; V. S. Kashikhin; V.V. Kashikhin; R. Kephart; M.J. Lamm; P.J. Limon; I. Novitski; D. Orris; Y. Pischalnikov; P. Schlabach; R. Stanek; J. Strait; C. Sylvester; M. Tartaglia; J.C. Tompkins; D. Turrioni; G.V. Velev; R. Yamada; V. Yarba

Fermilab is developing and investigating different high-field magnets (HFM) for present and future accelerators. The HFM R&D program focused on the 10-12 T magnets based on Nb/sub 3/Sn superconductor and explored both basic magnet technologies for brittle superconductors-wind-and-react and react-and-wind. Magnet design studies in support of LHC upgrades and VLHC were conducted. A series of 1-m long cos-theta dipole models based on the wind-and-react technique was fabricated and tested. Three 1-m long flat racetracks and the common coil dipole model, based on a single-layer coil and react-and-wind technique, were also fabricated and tested. Extensive theoretical and experimental studies of electro-magnetic instabilities in Nb/sub 3/Sn strands, cables and magnets were performed and led to a successful 10 T dipole model. This paper presents the details of Fermilabs HFM program, reports its status and major results, and formulates the next steps for the program.


IEEE Transactions on Applied Superconductivity | 2009

Fabrication and Test of LARP Technological Quadrupole Models of TQC Series

R. Bossert; Giorgio Ambrosio; N. Andreev; E. Barzi; G. Chlachidze; S. Feher; V. S. Kashikhin; Vadim V. Kashikhin; M.J. Lamm; A. Nobrega; I. Novitski; D. Orris; M. Tartaglia; Alexander V. Zlobin; S. Caspi; D.R. Dietderich; P. Ferracin; A.R. Hafalia; GianLuca Sabbi; A. Ghosh; P. Wanderer

In support of the development of a large-aperture Nb3Sn superconducting quadrupole for the Large Hadron Collider (LHC) luminosity upgrade, several two-layer technological quadrupole models of TQC series with 90 mm aperture and collar-based mechanical structure have been developed at Fermilab in collaboration with LBNL. This paper summarizes the results of fabrication and test of TQC02a, the second TQC model based on RRP Nb3Sn strand, and TQC02b, built with both MJR and RRP strand. The test results presented include magnet strain and quench performance during training, as well as quench studies of current ramp rate and temperature dependence from 1.9 K to 4.5 K.


IEEE Transactions on Applied Superconductivity | 2009

Test Results of LARP Nb3Sn Quadrupole Magnets Using a Shell-based Support Structure (TQS)

S. Caspi; D.R. Dietderich; H. Felice; P. Ferracin; R. Hafalia; C. R. Hannaford; A.F. Lietzke; J. Lizarazo; GianLuca Sabbi; X. Wang; A. Ghosh; P. Wanderer; Giorgio Ambrosio; E. Barzi; R. Bossert; G. Chlachidze; S. Feher; Vadim V. Kashikhin; M.J. Lamm; M. Tartaglia; Alexander V. Zlobin; M. Bajko; B. Bordini; Gijs DeRijk; C. Giloux; M. Karppinen; Juan Carlos Perez; L. Rossi; A. Siemko; E. Todesco

Amongst the magnet development program of a large-aperture Nb3Sn superconducting quadrupole for the Large Hadron Collider luminosity upgrade, six quadrupole magnets were built and tested using a shell based key and bladder technology (TQS). The 1 m long 90 mm aperture magnets are part of the US LHC Accelerator Research Program (LARP) aimed at demonstrating Nb3Sn technology by the year 2009, of a 3.6 m long magnet capable of achieving 200 T/m. In support of the LARP program the TQS magnets were tested at three different laboratories, LBNL, FNAL and CERN and while at CERN a technology-transfer and a four days magnet disassembly and reassembly were included. This paper summarizes the fabrication, assembly, cool-down and test results of the six magnets and compares measurements with design expectations.


IEEE Transactions on Applied Superconductivity | 2011

Test Results of the First 3.7 m Long Nb3Sn Quadrupole by LARP and Future Plans

G. Ambrosio; N. Andreev; M. Anerella; E. Barzi; B. Bingham; D. Bocian; R. Bossert; S. Caspi; G. Chlachidize; D.R. Dietderich; J. Escallier; H. Felice; P. Ferracin; A. Ghosh; A. Godeke; R. Hafalia; R. Hannaford; G. Jochen; V.V. Kashikhin; M. J. Kim; P. Kovach; M.J. Lamm; A.D. McInturff; J. Muratore; F. Nobrega; I. Novitsky; D. Orris; E. Prebys; S. Prestemon; G. Sabbi

In December 2009 during its first cold test, LQS01, the first Long Nb3Sn Quadrupole made by LARP (LHC Accelerator Research Program, a collaboration of BNL, FNAL, LBNL and SLAC), reached its target field gradient of 200 T/m. This target was set in 2005 by the US Department of Energy, CERN and LARP, as a significant milestone toward the development of Nb3Sn quadrupoles for possible use in LHC luminosity upgrades. LQS01 is a 90 mm aperture, 3.7 m long quadrupole using Nb3Sn coils. The coil layout is equal to the layout used in the LARP Technological Quadrupoles (TQC and TQS models). Pre-stress and support are provided by a segmented aluminum shell pre-loaded using bladders and keys, similarly to the TQS models. After the first test the magnet was disassembled, reassembled with an optimized pre-stress, and reached 222 T/m at 4.5 K. In this paper we present the results of both tests and the next steps of the Long Quadrupole R&D.


Proceedings of the 1997 Particle Accelerator Conference (Cat. No.97CH36167) | 1997

A new facility to test superconducting accelerator magnets

M.J. Lamm; J. DiMarco; E. Desavouret; S. Feher; J.D. Garvey; C. Hess; P.J. Limon; Jerzy Nogiec; D. Orris; J. Pachnik; T. Peterson; S. Sharonov; J. Strait; C. Sylvester; J.W. Sim; M. Tartaglia; J.C. Tompkins; A.V. Zlobin

Future high energy accelerators such as the Large Hadron Collider require accelerator magnets with the highest possible fields. For NbTi conductor magnets, this means operating at superfluid helium temperatures in the range of 1.8-1.9 K. As part of Fermilabs superconducting magnet R&D program, we have built a facility to test magnets in a vertical dewar of superfluid liquid helium. The dewar is designed for magnets up to 4 m length and 620 mm diameter, with a temperature range of 1.8 K to 4.4 K and 1 atmosphere helium. The power system consists of 10 kA and 8.8 kA power supplies operating in parallel, with a bus work and an extraction circuit that can accommodate up a 18 kA excitation current. A description of the facility as well as operational experience from the first magnet tests are presented.


IEEE Transactions on Applied Superconductivity | 2007

Development and Test of LARP Technological Quadrupole (TQC) Magnet

S. Feher; R. Bossert; G. Ambrosio; N. Andreev; E. Barzi; R. Carcagno; V. S. Kashikhin; V.V. Kashikhin; M.J. Lamm; F. Nobrega; I. Novitski; Y. Pischalnikov; C. Sylvester; M. Tartaglia; D. Turrioni; G. Whitson; R. Yamada; A.V. Zlobin; S. Caspi; D. T. Dietderich; P. Ferracin; R. Hannaford; A.R. Hafalia; G. Sabbi

In support of the development of a large-aperture superconducting quadrupole for the Large Hadron Collider (LHC) luminosity upgrade, two-layer quadrupole models (TQC and TQS) with 90 mm aperture are being constructed at Fermilab and LBNL within the framework of the US LHC Accelerator Research Program (LARP). This paper describes the construction and test of model TQC01. ANSYS calculations of the structure are compared with measurements during construction. Fabrication experience is described and in-process measurements are reported. Test results at 4.5 K are presented, including magnet training, current ramp rate studies and magnet quench current. Results of magnetic measurements at helium temperature are also presented.


IEEE Transactions on Applied Superconductivity | 2001

Status of the LHC inner triplet quadrupole program at Fermilab

N. Andreev; T. Arkan; P. Bauer; R. Bossert; J. Brandt; J. Carson; S. Caspi; D.R. Chichili; L. Chiesa; Christine Darve; J. DiMarco; S. Feher; A. Ghosh; H. Glass; Y. Huang; J. Kerby; M.J. Lamm; A.A. Markarov; A.D. McInturff; T. H. Nicol; A. Nobrega; I. Novitski; T. Ogitsu; D. Orris; J.P. Ozelis; T. Page; T. Peterson; R. Rabehl; W. Robotham; G. Sabbi

Fermilab, in collaboration with LBNL and BNL, is developing a quadrupole for installation in the interaction region inner triplets of the LHC. This magnet is required to have an operating gradient of 215 T/m across a 70 mm coil bore, and operates in superfluid helium at 1.9 K. A 2 m magnet program addressing mechanical, magnetic, quench protection, and thermal issues associated with the design was completed earlier this year, and production of the first full length, cryostatted prototype magnet is underway. This paper summarizes the conclusions of the 2 m program, and the design and status of the first full-length prototype magnet.


IEEE Transactions on Applied Superconductivity | 2013

Application of PCB and FDM Technologies to Magnetic Measurement Probe System Development

J. DiMarco; G. Chlachidze; A. Makulski; D. Orris; M. Tartaglia; J.C. Tompkins; G. Velev; X. Wang

Rotating coil probes are essential for measuring harmonic multipole fields of accelerator magnets. A fundamental requirement of these probes is their accuracy, which typically implies that the probes need to be very stiff and straight, have highly accurate knowledge of the placement of windings, and an ability to buck the fundamental fields well in order to suppress the effects of vibrations. Ideally, for an R&D test environment, probe fabrication should also be easy and low-cost, so that probe parameters (type, length, number of turns, radius, etc.) can be customized to the magnet requiring test. Such facility allows measurement optimization for magnets of various multipolarity, aperture size, cable twist pitch, etc. The accuracy and construction flexibility aspects of probe development, however, are often at odds with each other. This paper reports on application of printed-circuit board and fused-deposition modeling technologies, and what these offer to the fabrication of magnetic measurement probe systems.


IEEE Transactions on Applied Superconductivity | 2005

Development and test of Nb/sub 3/Sn cos-theta dipoles based on PIT strands

A.V. Zlobin; G. Ambrosio; N. Andreev; E. Barzi; R. Bossert; R. Carcagno; D.R. Chichili; L. Elementi; S. Feher; V. S. Kashikhin; V.V. Kashikhin; M.J. Lamm; I. Novitski; Y. Pischalnikov; C. Sylvester; M. Tartaglia; R. Yamada

Fermilab is involved in the development of new generation high-field accelerator magnets using state-of-the-art Nb/sub 3/Sn strands produced using different technologies. Two 1-m long models-mirror configuration and dipole magnet-were fabricated recently at Fermilab based on powder-in-tube (PIT) Nb/sub 3/Sn strands with small effective filament size. This paper describes the parameters of superconducting strands and cable, the details of magnet design and fabrication procedure, and reports the results of PIT coil testing.


IEEE Transactions on Applied Superconductivity | 2014

Performance of HQ02, an Optimized Version of the 120 mm

G. Chlachidze; Giorgio Ambrosio; Michael Anerella; F. Borgnolutti; R. Bossert; S. Caspi; D. W. Cheng; D.R. Dietderich; H. Felice; P. Ferracin; A. Ghosh; A. Godeke; A.R. Hafalia; M. Marchevsky; D. Orris; Pallab Kanti Roy; G. Sabbi; T. Salmi; J. Schmalzle; C. Sylvester; M. Tartaglia; J.C. Tompkins; P. Wanderer; X. Wang; A.V. Zlobin

In preparation for the high luminosity upgrade of the Large Hadron Collider (LHC), the LHC Accelerator Research Program (LARP) is developing a new generation of large aperture high-field quadrupoles based on Nb3Sn technology. One meter long and 120 mm diameter HQ quadrupoles are currently produced as a step toward the eventual aperture of 150 mm. Tests of the first series of HQ coils revealed the necessity for further optimization of the coil design and fabrication process. A new model (HQ02) has been fabricated with several design modifications, including a reduction of the cable size and an improved insulation scheme. Coils in this magnet are made of a cored cable using 0.778 mm diameter Nb3Sn strands of RRP 108/127 subelement design. The HQ02 magnet has been fabricated at LBNL and BNL, and then tested at Fermilab. This paper summarizes the performance of HQ02 at 4.5 K and 1.9 K temperatures.

Collaboration


Dive into the M. Tartaglia's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge