Norsiah Yunus
University of Malaya
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Norsiah Yunus.
Journal of Prosthodontics | 2013
Muaiyed Mahmoud Buzayan; Yusnidar T. Ariffin; Norsiah Yunus
A method is described for the fabrication of a closed hollow bulb obturator prosthesis using a hard thermoforming splint material and heat-cured acrylic resin. The technique allowed the thickness of the thermoformed bulb to be optimized for weight reduction, while the autopolymerized seal area was covered in heat-cured acrylic resin, thus eliminating potential leakage and discoloration. This technique permits the obturator prosthesis to be processed to completion from the wax trial denture without additional laboratory investing, flasking, and processing.
International Journal of Oral & Maxillofacial Implants | 2014
Norsiah Yunus; Roslan Saub; Taiyeb Ali Tb; Salleh Nm; Mirza Rustum Baig
PURPOSE The purpose of this study was to evaluate and compare Oral Health-Related Quality of Life (OHRQoL), denture satisfaction, and masticatory performance in edentulous patients provided with mandibular implant-supported overdentures (ISODs) retained with telescopic attachments and those of conventional complete dentures (CCDs). Peri-implant soft tissue changes were also evaluated at various intervals during a 1-year observation period. MATERIALS AND METHODS Participating patients received new CCDs and later received two mandibular interforaminal implants and had their mandibular CCDs converted into ISODs with telescopic attachments. Questionnaires were used to assess OHRQoL (Shortened Oral Health Impact Profile-14, Malaysian version) and denture satisfaction at different stages of treatment with CCDs and ISODs. Objective masticatory performance with the CCDs and ISODs was recorded with a mixing ability test. Evaluations were carried out at 3 months with the new CCDs, 3 months after mandibular ISOD provision, and 1 year after receiving the ISOD. Peri-implant parameters were additionally assessed at specific intervals during the treatment period. The data obtained were statistically analyzed and compared. RESULTS In the 17 patients who completed the protocol, significant improvements were observed in OHRQoL and patient satisfaction when CCDs were modified to ISODs, after 3 months, and at 1 year. Significantly better mixing ability with the ISOD was noted, with the highest values observed at 1 year. Statistically insignificant differences were observed for all the peri-implant parameters, except for gingival recession, for which significant changes were observed 6 months after ISOD delivery (values had stabilized by 1 year). CONCLUSION Telescopic crown attachment-retained mandibular ISODs improved OHRQoL, dental prosthesis satisfaction, and masticatory performance compared to CCDs. Peri-implant soft tissue response and implant stability were found to be favorable after 1 year.
The Journal of Indian Prosthodontic Society | 2014
Muaiyed Mahmoud Buzayan; Norsiah Yunus
One of the considerable challenges for screw-retained multi-unit implant prosthesis is achieving a passive fit of the prosthesis’ superstructure to the implants. This passive fit is supposed to be one of the most vital requirements for the maintenance of the osseointegration. On the other hand, the misfit of the implant supported superstructure may lead to unfavourable complications, which can be mechanical or biological in nature. The manifestations of these complications may range from fracture of various components in the implant system, pain, marginal bone loss, and even loss of osseointegration. Thus, minimizing the misfit and optimizing the passive fit should be a prerequisite for implant survival and success. The purpose of this article is to present and summarize some aspects of the passive fit achieving and improving methods. The literature review was performed through Science Direct, Pubmed, and Google database. They were searched in English using the following combinations of keywords: passive fit, implant misfit and framework misfit. Articles were selected on the basis of whether they had sufficient information related to framework misfit’s related factors, passive fit and its achievement techniques, marginal bone changes relation with the misfit, implant impression techniques and splinting concept. The related references were selected in order to emphasize the importance of the passive fit achievement and the misfit minimizing. Despite the fact that the literature presents considerable information regarding the framework’s misfit, there was not consistency in literature on a specified number or even a range to be the acceptable level of misfit. On the other hand, a review of the literature revealed that the complete passive fit still remains a tricky goal to be achieved by the prosthodontist.
Quintessence International | 2014
Muaiyed Mahmoud Buzayan; Wan Adida Azina Binti Mahmood; Norsiah Yunus
Retrieval of cement-retained implant prostheses can be more demanding than retrieval of screw-retained prostheses. This case report describes a simple and predictable procedure to locate the abutment screw access openings of cementretained implant-supported crowns in cases of fractured ceramic veneer. A conventional periapical radiography image was captured using a digital camera, transferred to a computer, and manipulated using Microsoft Word document software to estimate the location of the abutment screw access.
Gerodontology | 2012
Mirza Rustum Baig; Gunaseelan Rajan; Norsiah Yunus
Dental rehabilitation of a completely edentulous geriatric patient has always been a challenge to the clinician, especially in treating those with higher expectations and demands. Treatment duration and the amount of residual alveolar bone available are often important considerations when planning for dental implant-based fixed treatment for these patients. With the introduction of zygomatic implants, a graftless alternative solution has emerged for deficient maxillary bone with provision for immediate loading. This article describes the treatment of a completely edentulous elderly patient using zygomatic implants in conjunction with conventional implants. The implants were immediately loaded using a definitive acrylic resin fixed denture reinforced with a cast metal framework, to provide function and aesthetics.
Journal of Applied Oral Science | 2010
Safa Salim Elhadiry; Norsiah Yunus; Yusnidar T. Ariffin
Objective To investigate the effect of cavity preparation on the flexural strength of heat-curing denture resin when repaired with an auto-curing resin. Material and methods Ninety-six rectangular specimens (64x10x2.5 mm) prepared from heat-curing denture base resin (Meliodent) were randomly divided into four groups before repair. One group was left intact as control. Each repair specimen was sectioned into two; one group was repaired using the conventional repair method (Group 1). Two groups had an additional transverse cavity (2x3.5x21.5 mm) prepared prior to the repair; one repaired with (Group 2) and one without glass-fiber reinforcement (Group 3). A three-point flexural bending test according to the ISO 1567:1999 specification8 for denture base polymers was carried out on all groups after 1, 7 and 30 days of water immersion. Statistical analysis was carried out using two-way ANOVA, Kruskal Wallis and post-hoc Mann Whitney tests. Results The highest flexural strength was observed in the control group. Control and conventional repairs group (Group 1) showed reduction in the flexural strength 30 days after water immersion. No significant change in the strength was observed for Groups 2 and 3 where the repair joints were similarly prepared with additional transverse cavity. Conclusion Repaired specimens showed lower flexural strength values than intact heat-curing resin. Cavity preparation had no significant effect on the flexural strength of repair with water immersion.
Journal of Prosthodontics | 2015
Muaiyed Mahmoud Buzayan; Yusnidar T. Ariffin; Norsiah Yunus; Wan Adida Azina Binti Mahmood
Ocular disorders occasionally necessitate surgical intervention that may lead to eye defects. The primary objective in restoring and rehabilitating such defects with an ocular prosthesis is to enable patients to cope better with associated psychological stress and to return to their accustomed lifestyle. A series of detailed steps for custom-made ocular prosthesis fabrication using the advantages of digital photography to replace the conventional oil paint and monopoly iris painting technique are presented in this article. In the present case, a digital photograph of the patients iris was captured using a digital camera and manipulated on a computer using graphic software to produce a replica of the natural iris. The described technique reduces treatment time, increases simplicity, and permits the patients natural iris to be replicated without the need for iris painting and special artistic skills.
Periodontics and Prosthodontics | 2016
Muaiyed Mahmoud Buzayan; Norsiah Yunus; Siti Mazlipah Binti Ismail; Safa Salim Elhadiry
The rehabilitation of a patient with partial resection of soft palate is a challenge. Surgical management is considered one of the preferred treatment options for such cases. However, this is not possible in several clinical situations, for such situations the prosthetic management would be a valuable alternative. This clinical report describes the rehabilitation of an acquired palatal defect with palatal prosthesis to restore the physical separation between the nasopharynx and oropharynx.
Archive | 2013
Norsiah Yunus
A method is described for the fabrication of a closed hollow bulb obturator prosthesis using a hard thermoforming splint material and heat-cured acrylic resin. The technique allowed the thickness of the thermoformed bulb to be optimized for weight reduction, while the autopolymerized seal area was covered in heat-cured acrylic resin, thus eliminating potential leakage and discoloration. This technique permits the obturator prosthesis to be processed to completion from the wax trial denture without additional laboratory investing, flasking, and processing.
Indian Journal of Dental Research | 2011
Mirza Rustum Baig; Fazrina T.M. Ariff; Norsiah Yunus
BACKGROUND The clinical success of relining depends on the ability of reline resin to bond to denture base. Surface preparations may influence reline bond strength of urethane-based dimethacrylate denture base resin. AIM To investigate the effect of bur preparation on the surface roughness (R a ) of eclipse denture base resin and its shear bond strength (SBS) to an intra-oral self-curing reline material. The mode of reline bonding failure was also examined. MATERIALS AND METHODS Twenty-four cylindrical Eclipse™ specimens were prepared and separated into three groups of eight specimens each. Two groups were subjected to mechanical preparation using standard and fine tungsten carbide (TC) burs and the third group (control) was left unprepared. The R a of all specimens was measured using a contact stylus profilometer. Subsequently, relining was done on the prepared surface and SBS testing was carried out a day later using a universal testing machine. RESULTS One-way ANOVA revealed significant differences (P<0.05) in R a and SBS values for all the groups. Post-hoc Tukeys HSD test showed significant differences (P<0.05) between all the groups in the R a values. For SBS also there were significant differences (P<0.05), except between standard bur and control. CONCLUSIONS 1) There was a statistically significant difference in the R a of Eclipse™ specimens prepared using different carbide burs (P<0.05). 2) There was a statistically significant difference in the relined SBS (P<0.05) when prepared using different burs, but the difference between the standard bur and the control group was not statistically significant.