Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Ou Yi is active.

Publication


Featured researches published by Ou Yi.


Chinese Physics B | 2010

A novel anti-shock silicon etching apparatus for solving diaphragm release problems

Shi Shali; Chen Dapeng; Ou Yi; Jing Yupeng; Xu Qiuxia; Ye Tianchun

This paper presents a novel anti-shock bulk silicon etching apparatus for solving a universal problem which occurs when releasing the diaphragm (e.g. SiNx), that the diaphragm tends to be probably cracked by the impact of heating-induced bubbles, the swirling of heating-induced etchant, dithering of the hand and imbalanced etchant pressure during the wafer being taken out. Through finite element methods, the causes of the diaphragm cracking are analysed. The impact of heating-induced bubbles could be the main factor which results in the failure stress of the SiNx diaphragm and the rupture of it. In order to reduce the four potential effects on the cracking of the released diaphragm, an anti-shock bulk silicon etching apparatus is proposed for using during the last etching process of the diaphragm release. That is, the silicon wafer is first put into the regular constant temperature etching apparatus or ultrasonic plus, and when the residual bulk silicon to be etched reaches near the interface of the silicon and SiNx diaphragm, within a distance of 50–80 μm (the exact value is determined by the thickness, surface area and intensity of the released diaphragm), the wafer is taken out carefully and put into the said anti-shock silicon etching apparatus. The wafers position is at the geometrical centre, also the centre of gravity of the etching vessel. An etchant outlet is built at the bottom. The wafer is etched continuously, and at the same time the etchant flows out of the vessel. Optionally, two symmetrically placed low-power heating resistors are put in the anti-shock silicon etching apparatus to quicken the etching process. The heating resistors power should be low enough to avoid the swirling of the heating-induced etchant and the impact of the heating-induced bubbles on the released diaphragm. According to the experimental results, the released SiNx diaphragm thus treated is unbroken, which proves the practicality of the said anti-shock bulk silicon etching apparatus.


Chinese Physics B | 2008

Micro thermal shear stress sensor based on vacuum anodic bonding and bulk-micromachining

Yi Liang; Ou Yi; Shi Shali; Ma Jin; Chen Dapeng; Ye Tianchun

This paper describes a micro thermal shear stress sensor with a cavity underneath, based on vacuum anodic bonding and bulk micromachined technology. A Ti/Pt alloy strip, 2μm × 100μm, is deposited on the top of a thin silicon nitride diaphragm and functioned as the thermal sensor element. By using vacuum anodic bonding and bulk-si anisotropic wet etching process instead of the sacrificial-layer technique, a cavity, functioned as the adiabatic vacuum chamber, 200μm × 200μm × 400μm, is placed between the silicon nitride diaphragm and glass (Corning 7740). This method totally avoid adhesion problem which is a major issue of the sacrificial-layer technique.


Archive | 2013

PM 2.5 filtration structure and preparation method thereof

Mao Haiyang; Wu Wengang; Ou Wen; Ou Yi


Archive | 2014

Miniature piezoelectric vibration energy collector and manufacturing method thereof

Wu Hang; Ou Yi; Zheng Taolei; Ou Wen; Liu Yu


Archive | 2015

Hole forming method of single event effect test chip

Li Zhigang; Lu Dike; Ou Yi; Ou Wen; Liu Gang; Chen Dapeng


Archive | 2015

Broadband vibration energy collector structure and manufacturing method thereof

Li Zhigang; Ou Yi; Ou Wen; Chen Dapeng; Ye Tianchun


Archive | 2014

Measuring mechanism for seebeck coefficient of nano-scale material and fabrication method of measuring mechanism

Mao Haiyang; Ou Wen; Ou Yi; Chen Dapeng


Archive | 2013

Fabrication method of measuring mechanism for seebeck coefficient of nano-scale material

Mao Haiyang; Ou Wen; Ou Yi; Chen Dapeng


Archive | 2013

Transverse comb tooth type micro-electromechanical vibration energy collector

Ou Yi; Chen Dapeng; Ye Tianchun; Liu Yu


Archive | 2015

High-performance micro-electromechanical system (MEMS) thermopile infrared detector structure and manufacturing method thereof

Mao Haiyang; Ou Wen; Wu Wengang; Ou Yi

Collaboration


Dive into the Ou Yi's collaboration.

Top Co-Authors

Avatar

Chen Dapeng

Chinese Academy of Sciences

View shared research outputs
Top Co-Authors

Avatar

Ye Tianchun

Chinese Academy of Sciences

View shared research outputs
Top Co-Authors

Avatar

Ou Wen

Chinese Academy of Sciences

View shared research outputs
Top Co-Authors

Avatar

Li Zhigang

Chinese Academy of Sciences

View shared research outputs
Top Co-Authors

Avatar

Mao Haiyang

North University of China

View shared research outputs
Top Co-Authors

Avatar

Shi Shali

Chinese Academy of Sciences

View shared research outputs
Top Co-Authors

Avatar

Jing Yupeng

Chinese Academy of Sciences

View shared research outputs
Top Co-Authors

Avatar

Liu Gang

Northwestern Polytechnical University

View shared research outputs
Top Co-Authors

Avatar

Liu Yu

Southwest Jiaotong University

View shared research outputs
Top Co-Authors

Avatar

Lu Dike

Chinese Academy of Sciences

View shared research outputs
Researchain Logo
Decentralizing Knowledge