Rachael E. H. Miles
University of Bristol
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Rachael E. H. Miles.
Proceedings of the National Academy of Sciences of the United States of America | 2013
James F. Davies; Rachael E. H. Miles; Allen E. Haddrell; Jonathan P. Reid
Uncertainties in quantifying the kinetics of evaporation and condensation of water from atmospheric aerosol are a significant contributor to the uncertainty in predicting cloud droplet number and the indirect effect of aerosols on climate. The influence of aerosol particle surface composition, particularly the impact of surface active organic films, on the condensation and evaporation coefficients remains ambiguous. Here, we report measurements of the influence of organic films on the evaporation and condensation of water from aerosol particles. Significant reductions in the evaporation coefficient are shown to result when condensed films are formed by monolayers of long-chain alcohols [CnH(2n+1)OH], with the value decreasing from 2.4 × 10−3 to 1.7 × 10−5 as n increases from 12 to 17. Temperature-dependent measurements confirm that a condensed film of long-range order must be formed to suppress the evaporation coefficient below 0.05. The condensation of water on a droplet coated in a condensed film is shown to be fast, with strong coherence of the long-chain alcohol molecules leading to islanding as the water droplet grows, opening up broad areas of uncoated surface on which water can condense rapidly. We conclude that multicomponent composition of organic films on the surface of atmospheric aerosol particles is likely to preclude the formation of condensed films and that the kinetics of water condensation during the activation of aerosol to form cloud droplets is likely to remain rapid.
Journal of Physical Chemistry A | 2013
Andrew M. J. Rickards; Rachael E. H. Miles; James F. Davies; Frances H. Marshall; Jonathan P. Reid
We report measurements of the subsaturated hygroscopic growth of aerosol particles composed of single organic components of varying oxygen-to-carbon ratio up to relative humidities approaching saturation using the techniques of aerosol optical tweezers and an electrodynamic balance. The variation in the hygroscopicity parameter κ between compounds of even the same O/C ratio is found to be significant with, for example, a range in κ values from 0.12 to 0.38 for compounds with an O/C of 1. The measurements are compared with a review of all of the available literature data for which both the κ value and O/C ratio are reported, and a new parametrization is determined. Critical supersaturations predicted using this parametrization yield values that have associated uncertainties that are comparable to typical uncertainties in experimental measurements of critical supersaturations. However, the systematic variability between κ parametrizations determined from different studies remains large, consistent with the O/C ratio providing only an approximate guide to aerosol hygroscopicity and reflecting significant variations for aerosols of different chemical functionality, composition, and oxidation history.
Physical Chemistry Chemical Physics | 2012
Rachael E. H. Miles; Jim S. Walker; Daniel R. Burnham; Jonathan P. Reid
The cavity enhanced Raman scattering spectrum recorded from an aerosol droplet provides a unique fingerprint of droplet radius and refractive index, assuming that the droplet is homogeneous in composition. Aerosol optical tweezers are used in this study to capture a single droplet and a Raman fingerprint is recorded using the trapping laser as the source for the Raman excitation. We report here the retrieval of the real part of the refractive index with an uncertainty of ± 0.0012 (better than ± 0.11%), simultaneously measuring the size of the micrometre sized liquid droplet with a precision of better than 1 nm (< ± 0.05% error). In addition, the equilibrium size of the droplet is shown to depend on the laser irradiance due to optical absorption, which elevates the droplet temperature above that of the ambient gas phase. Modulation of the illuminating laser power leads to a modulation in droplet size as the temperature elevation is altered. By measuring induced size changes of <1 nm, we show that the imaginary part of the refractive index can be retrieved even when less than 10 × 10(-9) with an accuracy of better than ± 0.5 × 10(-9). The combination of these measurements allows the complex refractive index of a droplet to be retrieved with high accuracy, with the possibility of making extremely sensitive optical absorption measurements on aerosol samples and the testing of frequently used mixing rules for treating aerosol optical properties. More generally, this method provides an extremely sensitive approach for measuring refractive indices, particularly under solute supersaturation conditions that cannot be accessed by simple bulk-phase measurements.
Journal of Physical Chemistry A | 2012
James F. Davies; Allen E. Haddrell; Rachael E. H. Miles; Craig R. Bull; Jonathan P. Reid
The influence of solute species on mass transfer to and from aqueous aerosol droplets is investigated using an electrodynamic balance coupled with light scattering techniques. In particular, we explore the limitations imposed on water evaporation by slow bulk phase diffusion and by the formation of surface organic films. Measurements of evaporation from ionic salt solutions, specifically sodium chloride and ammonium sulfate, are compared with predictions from an analytical model framework, highlighting the uncertainties associated with quantifying gas diffusional transport. The influence of low solubility organic acids on mass transfer is reported and compared to both model predictions and previous work. The limiting value of the evaporation coefficient that can be resolved by this approach, when uncertainties in key thermophysical quantities are accounted for, is estimated. The limitation of slow bulk phase diffusion on the evaporation rate is investigated for gel and glass states formed during the evaporation of magnesium sulfate and sucrose droplets, respectively. Finally, the effect of surfactants on evaporation has been probed, with soluble surfactants (such as sodium dodecyl sulfate) leading to little or no retardation of evaporation through slowing of surface layer kinetics.
Journal of Physical Chemistry A | 2012
Rachael E. H. Miles; Jonathan P. Reid; Ilona Riipinen
We compare and contrast measurements of the mass accommodation coefficient of water on a water surface made using ensemble and single particle techniques under conditions of supersaturation and subsaturation, respectively. In particular, we consider measurements made using an expansion chamber, a continuous flow streamwise thermal gradient cloud condensation nuclei chamber, the Leipzig Aerosol Cloud Interaction Simulator, aerosol optical tweezers, and electrodynamic balances. Although this assessment is not intended to be comprehensive, these five techniques are complementary in their approach and give values that span the range from near 0.1 to 1.0 for the mass accommodation coefficient. We use the same semianalytical treatment to assess the sensitivities of the measurements made by the various techniques to thermophysical quantities (diffusion constants, thermal conductivities, saturation pressure of water, latent heat, and solution density) and experimental parameters (saturation value and temperature). This represents the first effort to assess and compare measurements made by different techniques to attempt to reduce the uncertainty in the value of the mass accommodation coefficient. Broadly, we show that the measurements are consistent within the uncertainties inherent to the thermophysical and experimental parameters and that the value of the mass accommodation coefficient should be considered to be larger than 0.5. Accurate control and measurement of the saturation ratio is shown to be critical for a successful investigation of the surface transport kinetics during condensation/evaporation. This invariably requires accurate knowledge of the partial pressure of water, the system temperature, the droplet curvature and the saturation pressure of water. Further, the importance of including and quantifying the transport of heat in interpreting droplet measurements is highlighted; the particular issues associated with interpreting measurements of condensation/evaporation rates with varying pressure are discussed, measurements that are important for resolving the relative importance of gas diffusional transport and surface kinetics.
Journal of Physical Chemistry A | 2013
Jan Julin; Manabu Shiraiwa; Rachael E. H. Miles; Jonathan P. Reid; Ulrich Pöschl; Ilona Riipinen
The condensational growth of submicrometer aerosol particles to climate relevant sizes is sensitive to their ability to accommodate vapor molecules, which is described by the mass accommodation coefficient. However, the underlying processes are not yet fully understood. We have simulated the mass accommodation and evaporation processes of water using molecular dynamics, and the results are compared to the condensation equations derived from the kinetic gas theory to shed light on the compatibility of the two. Molecular dynamics simulations were performed for a planar TIP4P-Ew water surface at four temperatures in the range 268–300 K as well as two droplets, with radii of 1.92 and 4.14 nm at T = 273.15 K. The evaporation flux from molecular dynamics was found to be in good qualitative agreement with that predicted by the simple kinetic condensation equations. Water droplet growth was also modeled with the kinetic multilayer model KM-GAP of Shiraiwa et al. [Atmos. Chem. Phys.2012, 117, 2777]. It was found that, due to the fast transport across the interface, the growth of a pure water droplet is controlled by gas phase diffusion. These facts indicate that the simple kinetic treatment is sufficient in describing pure water condensation and evaporation. The droplet size was found to have minimal effect on the value of the mass accommodation coefficient. The mass accommodation coefficient was found to be unity (within 0.004) for all studied surfaces, which is in agreement with previous simulation work. Additionally, the simulated evaporation fluxes imply that the evaporation coefficient is also unity. Comparing the evaporation rates of the mass accommodation and evaporation simulations indicated that the high collision flux, corresponding to high supersaturation, present in typical molecular dynamics mass accommodation simulations can under certain conditions lead to an increase in the evaporation rate. Consequently, in such situations the mass accommodation coefficient can be overestimated, but in the present cases the corrected values were still close to unity with the lowest value at ≈0.99.
Journal of Physical Chemistry A | 2012
Benjamin J. Dennis-Smither; Kate L. Hanford; Nana-Owusua A. Kwamena; Rachael E. H. Miles; Jonathan P. Reid
Aerosol optical tweezers are used to probe the phase, morphology, and hygroscopicity of single aerosol particles consisting of an inorganic component, sodium chloride, and a water insoluble organic component, oleic acid. Coagulation of oleic acid aerosol with an optically trapped aqueous sodium chloride droplet leads to formation of a phase-separated particle with two partially engulfed liquid phases. The dependence of the phase and morphology of the trapped particle with variation in relative humidity (RH) is investigated by cavity enhanced Raman spectroscopy over the RH range <5% to >95%. The efflorescence and deliquescence behavior of the inorganic component is shown to be unaffected by the presence of the organic phase. Whereas efflorescence occurs promptly (<1 s), the deliquescence process requires both dissolution of the inorganic component and the adoption of an equilibrium morphology for the resulting two phase particle, occurring on a time-scale of <20 s. Comparative measurements of the hygroscopicity of mixed aqueous sodium chloride/oleic acid droplets with undoped aqueous sodium chloride droplets show that the oleic acid does not impact on the equilibration partitioning of water between the inorganic component and the gas phase or the time response of evaporation/condensation. The oxidative aging of the particles through reaction with ozone is shown to increase the hygroscopicity of the organic component.
Physical Chemistry Chemical Physics | 2010
Rachael E. H. Miles; Svemir Rudić; Andrew J. Orr-Ewing; Jonathan P. Reid
Cavity ring down measurements are performed on accumulation mode aerosol, 240 nm to 700 nm in diameter, over a range in wavelength, extending from 540 to 570 nm. We demonstrate that the measured variation in extinction efficiency with wavelength can be used to retrieve the dispersion in the real part of the refractive index. These measurements are contrasted with previous aerosol cavity ring down studies which have focussed on investigating the variation in optical extinction with particle size parameter through a variation in the sampled particle size distribution. In the measurements reported here, the gradient in the optical extinction can be recorded with fine resolution in size parameter (approximately 0.02) through variation in laser wavelength. Such an approach, as well as allowing a determination of the dispersion in refractive index, could be used to constrain the retrieval of refractive index at a single wavelength.
Journal of Physical Chemistry A | 2010
Rachael E. H. Miles; Svemir Rudić; Andrew J. Orr-Ewing; Jonathan P. Reid
We consider the impact of uncertainties in the refractive index and size of polystyrene beads on the retrieved optical properties of aerosol particles by aerosol cavity ring down spectroscopy (A-CRDS). Polystyrene beads are frequently used to verify and calibrate light extinction measurements by cavity ring down instruments. Any uncertainties in either the polymer particle size or the refractive index can contribute to systematic errors in properties retrieved for any subsequent measurements on other aerosol types. We demonstrate that the tolerances on bead size reported by the manufacturers can lead to a range in the real part of the refractive index of the polymer beads retrieved from A-CRDS measurements of as large as 2.9%. Further, we show that the current uncertainty in the refractive index of polystyrene beads in the visible part of the electromagnetic spectrum limits the accuracy with which the real part of the refractive index of other aerosol types can be retrieved to uncertainties of -0.5% and +0.3% at a minimum. This error should be included in any subsequent retrieval of aerosol optical properties from aerosol cavity ring down instruments that are dependent on polystyrene bead calibration. It is expected that such calibrations could lead to significantly larger uncertainties if the complex part of the refractive index is to be retrieved.
Aerosol Science and Technology | 2011
Rachael E. H. Miles; Svemir Rudić; Andrew J. Orr-Ewing; Jonathan P. Reid
The use of cavity ring down spectroscopy to retrieve aerosol complex refractive index from optical property measurements has seen increasing popularity over the past few years. However, few studies have looked at the limit which sources of error and uncertainty inherent in the cavity ring down method place on the accuracy with which the refractive index can be retrieved. In this paper, we consider both experimental sources of error and those which compromise the theoretical models against which measurements are compared, both reviewing previously published work and presenting new data. Our results show that for absolute measurements made using single-cavity instruments, factors such as uncertainty in the length of the ring down cavity occupied by aerosol and the counting efficiency of the CPC can introduce an error of ∼2.5% into the real part of the refractive index retrieved from experiment. This is significantly higher than the typical 1% error quoted in previously published work. We note that due to the dependence of particle extinction efficiency on diameter, the effect of a given error on measurements for different particle sizes is not constant.