Featured researches published by Sophie Williams.


Biomaterials | 2003

Comparison of the cytotoxicity of clinically relevant cobalt-chromium and alumina ceramic wear particles in vitro.

M.A. Germain; A. Hatton; Sophie Williams; J.B. Matthews; Martin H. Stone; John Fisher; E. Ingham

Concern over polyethylene wear particle induced aseptic loosening of metal-on-polyethylene hip prostheses has led to renewed interest in alternative materials such as metal-on-metal and alumina ceramic-on-alumina ceramic for total hip replacement. This study compared the effects of clinically relevant cobalt-chromium and alumina ceramic wear particles on the viability of U937 histiocytes and L929 fibroblasts in vitro. Clinically relevant cobalt-chromium wear particles were generated using a flat pin-on-plate tribometer. The mean size of the clinically relevant metal particles was 29.5+/-6.3 nm (range 5-200 nm). Clinically relevant alumina ceramic particles were generated in the Leeds MkII anatomical hip simulator from a Mittelmieier prosthesis using micro-separation motion. This produced particles with a bimodal size distribution. The majority (98%) of the clinically relevant alumina ceramic wear debris was 5-20 nm in size. The cytotoxicity of the clinically relevant wear particles was compared to commercially available cobalt-chromium (9.87 microm+/-5.67) and alumina ceramic (0.503+/-0.19 microm) particles. The effects of the particles on the cells over a 5 day period at different particle volume (microm(3)) to cell number ratios were tested and viability determined using ATP-Lite(TM). Clinically relevant cobalt-chromium particles 50 and 5 microm(3) per cell reduced the viability of U937 cells by 97% and 42% and reduced the viability of L929 cells by 95% and 73%, respectively. At 50 microm(3) per cell, the clinically relevant ceramic particles reduced U937 cell viability by 18%. None of the other concentrations of the clinically relevant particles were toxic. The commercial cobalt-chromium and alumina particles did not affect the viability of either the U937 histiocytes or the L929 fibroblasts.Thus at equivalent particle volumes the clinically relevant cobalt-chromium particles were more toxic then the alumina ceramic particles. This study has emphasised the fact that the nature, size and volume of particles are important in assessing biological effects of wear debris on cells in vitro.


Journal of Bone and Joint Surgery, American Volume | 2008

Tribology and wear of metal-on-metal hip prostheses: influence of cup angle and head position.

Sophie Williams; Ian Leslie; Graham Isaac; Zhongmin Jin; Eileen Ingham; John Fisher

BACKGROUND Clinical studies have indicated that the angular position of the acetabular cup may influence wear in metal-on-metal total hip bearings. A high cup angle in comparison to the anatomical position may lead to the head being constrained by the superior lateral surface and rim of the cup, thus potentially changing the location of the contact zone between the head and the cup. The aim of this study was to test the hypothesis that both a steep cup angle and a lateralized position of the head can increase head contact on the superior rim of the cup, with the consequence of increased wear. METHODS Hip-joint simulator studies of metal-on-metal bearings were undertaken with cup angles of 45 degrees and 55 degrees . The femoral head was either aligned to the center of the cup or placed in a position of microlateralization. Wear was measured gravimetrically over 5 million cycles. RESULTS A steep cup angle of 55 degrees showed significantly higher long-term steady-state wear than a standard cup angle of 45 degrees (p < 0.01). The difference was fivefold. Microlateralization of the head resulted in a fivefold increase in steady-state wear compared with a centralized head. The combination of a steep cup angle and a microlateralized head increased the steady-state wear rate by tenfold compared with a standard cup angle with a centralized head. CONCLUSIONS These studies support the hypothesis that both an increased cup angle and a lateral head position increase wear in metal-on-metal hip prostheses.


Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine | 2003

In vitro analysis of the wear, wear debris and biological activity of surface-engineered coatings for use in metal-on-metal total hip replacements.

Sophie Williams; Joanne L. Tipper; E. Ingham; Martin H. Stone; John Fisher

Abstract Extremely low wear rates have been reported for metal-on-metal total hip replacements, but concerns remain about the effects of metal ion release, dissolution rates and toxicity. Surface-engineered coatings have the potential to improve wear resistance and reduce the biological activity of the wear debris produced. The aim of this study was to examine the wear and wear debris generation from surface-engineered coatings: titanium nitride (TiN), chromium nitride (CrN) and chromium carbon nitride (CrCN) applied to a cobalt-chrome alloy (CoCr) substrate. The coatings were articulated against themselves in a simple geometry model. The wear particles generated were characterized and the cytotoxic effect on U937 macrophages and L929 fibroblasts assessed. The CrN and CrCN coatings showed a decrease in wear compared to the CoCr bearings and produced small (less than 40 nm in length) wear particles. The wear particles released from the surface engineered bearings also showed a decreased cytotoxic effect on cells compared to the CoCr alloy debris. The reduced wear volumes coupled with the reduced cytotoxicity per unit volume of wear indicate the potential for the clinical application of this technology.


Journal of Biomedical Materials Research Part B | 2008

Effect of bearing size on the long‐term wear, wear debris, and ion levels of large diameter metal‐on‐metal hip replacements—An in vitro study

Ian Leslie; Sophie Williams; Christopher Brown; Graham Isaac; Zhongmin Jin; Eileen Ingham; John Fisher

Hip resurfacing arthroplasty has become a popular alternative to conventional hip surgery. Surface replacements with bearing sizes of 55 mm (n = 5) and 39 mm (n = 5) were tested in a hip simulator for 15 million cycles (Mc). Wear debris was isolated from the serum lubricant and characterized by field emmitting gun scanning electorn microscopy, and ion levels were measured via inductively coupled plasma mass spectroscopy at intervals throughout the test. The 39 mm bearings showed significantly greater bedding in volumetric wear (2.58 mm(3)) compared with the 55 mm bearings (1.15 mm(3)). There was no significant difference between the steady state wear rates (1-15 Mc) between the two sizes (0.10 and 0.09 mm(3)/Mc, respectively); however, this parity only became clear after 7 Mc. The wear debris isolated was oval in morphology with a mean particle size of 28 nm and a range of 9-108 nm. The Co levels measured at 0.13 Mc were significantly greater than at 3.6 Mc for both bearing sizes (10926 ppb and 176 ppb, respectively). After 0.5 Mc, the Co levels from the 39 mm bearings were significantly higher than the 55 mm (11,007 vs. 1475 ppb). The wear results support previous findings showing that increasing the femoral head size decreased volumetric bedding in wear. The ion levels measured suggest both bearing sizes have similar initial wear rates; however, the 55 mm bearings reach steady state wear more rapidly.


Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine | 2002

An in vitro study of the reduction in wear of metal-on-metal hip prostheses using surface-engineered femoral heads

John Fisher; X.Q. Hu; Joanne L. Tipper; Todd Stewart; Sophie Williams; Martin H. Stone; C. Davies; Peter Hatto; J. Bolton; M. Riley; Catherine Hardaker; Graham Isaac; G. Berry; Eileen Ingham

Abstract Although the wear of existing metal-on-metal (MOM) hip prostheses (1 mm3/106 cycles) is much lower than the more widely used polyethylene-on-metal bearings, there are concerns about the toxicity of metal wear particles and elevated metal ion levels, both locally and systemically, in the human body. The aim of this study was to investigate the possibility of reducing the volume of wear, the concentration of metal debris and the level of metal ion release through using surfaceengineered femoral heads. Three thick (8-12 μm) coatings (TiN, CrN and CrCN) and one thin (2 μm) coating (diamond-like carbon, DLC), were evaluated on the femoral heads when articulating against high carbon content cobalt-chromium alloy acetabular inserts (HC CoCrMo) and compared with a clinically used MOM cobalt-chromium alloy bearing couple using a physiological anatomical hip joint simulator (Leeds Mark II). This study showed that CrN, CrCN and DLC coatings produced substantially lower wear volumes for both the coated femoral heads and the HC CoCrMo inserts. The TiN coating itself had little wear, but it caused relatively high wear of the HC CoCrMo inserts compared with the other coatings. The majority of the wear debris for all half-coated couples comprised small, 30 nm or less, CoCrMo metal particles. The Co, Cr and Mo ion concentrations released from the bearing couples of CrN-, CrCN- and DLC-coated heads articulating against HC CoCrMo inserts were at least 7 times lower than those released from the clinical MOM prostheses. These surface-engineered femoral heads articulating on HC CoCrMo acetabular inserts produced significantly lower wear volumes and rates, and hence lower volumetric concentrations of wear particles, compared with the clinical MOM prosthesis. The substantially lower ion concentration released by these surface-engineered components provides important evidence to support the clinical application of this technology.


Clinical Orthopaedics and Related Research | 2007

The 2007 Otto Aufranc Award. Ceramic-on-metal hip arthroplasties: a comparative in vitro and in vivo study.

Sophie Williams; A. Schepers; Graham Isaac; Catherine Hardaker; Eileen Ingham; van der Jagt D; A. Breckon; John Fisher

The performance of novel ceramic-on-metal bearing couples has been compared with metal-on-metal and ceramic-on-ceramic bearing couples in laboratory and short-term clinical studies. Laboratory studies compared ceramic-on-metal with metal-on-metal and ceramic-on-ceramic bearings with diameters of 28 and 36 mm under standard conditions and under adverse conditions with head loading on the rim of the cup. Clinical studies compared metal ion levels in ceramic-on-metal with metal-on-metal, ceramic-on-ceramic, and ceramic-on-polyethylene bearings in a randomized prospective study. In the laboratory studies, friction, wear, and ion levels were lower in ceramic-on-metal bearings compared with metal-on-metal, with results similar to ceramic-on-ceramic couples. Under adverse conditions and rim loading, all bearings showed increased wear with lower wear and absence of stripe wear in ceramic-on-metal compared with metal-on-metal bearings. Short-term studies in 31 patients at 6 months revealed lower metal ion levels (cobalt and chromium) in those with ceramic-on-metal compared with metal-on-metal bearings.Level of Evidence: Level II, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.


Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine | 2006

Metal-on-metal bearings surfaces: materials, manufacture, design, optimization, and alternatives.

Graham Isaac; Jonathan Thompson; Sophie Williams; John Fisher

Abstract When first introduced, total hip replacements offered pain relief and improved mobility in elderly patients. The success of this procedure in terms of long-term durability and restoration of function has led to its use in younger, more active patients. This has resulted in a commensurate increase in patient expectation regarding longevity and the degree to which function and lifestyle is restored. The bearing surface is a key feature of the performance of replacement joints. It is generally accepted that excessive amounts of wear debris preclude their long-term survivorship and hence there is an ongoing requirement for bearing surfaces which minimize debris generation. The purpose of this paper is to review the factors which affect the performance of so-called metal-on-metal bearings, to compare their performance with that of the other commonly used contemporary alternatives, metal and ceramic articulating against highly cross-linked polyethylene, and ceramic-on-ceramic, and finally to consider the potential solutions offered by new developments such as ceramic-on-metal and coatings applied to metal-on-metal bearings.


Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine | 2003

Wear and deformation of ceramic-on-polyethylene total hip replacements with joint laxity and swing phase microseparation

Sophie Williams; Butterfield M; Todd Stewart; E. Ingham; Martin H. Stone; John Fisher

Abstract Wear of polyethylene and the resulting wear debris-induced osteolysis remains a major cause of long-term failure in artificial hip joints. There is interest in understanding engineering and clinical conditions that influence wear rates. Fluoroscopic studies have shown separation of the head and the cup during the swing phase of walking due to joint laxity. In ceramic-on-ceramic hips, joint laxity and microseparation, which leads to contact of the head on the superior rim of the cup, has led to localized damage and increased wear in vivo and in vitro. The aim of this study was to investigate the influence of joint laxity and microseparation on the wear of ceramic on polyethylene artificial hip joints in an in vitro simulator. Microseparation during the swing phase of the walking cycle produced contact of the ceramic head on the rim of the polyethylene acetabular cup that deformed the softer polyethylene cup. No damage to the alumina ceramic femoral head was found. Under standard simulator conditions the volume change of the moderately crosslinked polyethylene cups was 25.6 ± 5.3 mm3/million cycles and this reduced to 5.6 ± 4.2 mm3/million cycles under microseparation conditions. Testing under microseparation conditions caused the rim of the polyethylene cup to deform locally, possibly due to creep, and the volume change of the polyethylene cup when the head relocated was substantially reduced, possibly due to improved lubrication. Joint laxity may be caused by poor soft tissue tension or migration and subsidence of components. In ceramic-on-polyethylene acetabular cups wear was decreased with a small degree of joint laxity, while in contrast in hard-on-hard alumina bearings, microseparation accelerated wear. These findings may have significant implications for the choice of fixation systems to be used for different types of bearing couples.


Journal of Biomedical Materials Research Part B | 2010

Effect of cup inclination angle during microseparation and rim loading on the wear of BIOLOX® delta ceramic‐on‐ceramic total hip replacement

Mazen Al-Hajjar; Ian Leslie; Joanne L. Tipper; Sophie Williams; John Fisher; Louise Jennings

Ceramic-on-ceramic (CoC) bearings in total hip replacements (THRs) have shown low wear volumes under standard gait in hip simulator studies. However, clinical reports have indicated variations in wear rates and formation of stripe-like wear area on the ceramic femoral heads. The aim of this study was to investigate the influence of cup inclination angle and microseparation on the wear of CoC bearings in THRs. The six station Leeds II Physiological Anatomical Joint Simulator was used to investigate the wear of 28 mm diameter alumina matrix composite ceramic bearings (BIOLOX® delta). It was shown that increasing the cup inclination angle from 55° to 65° had no significant effect on the wear rate of BIOLOX® delta CoC under both standard gait and microseparation conditions in this in vitro study. Under standard gait conditions, the mean wear rate for both cup inclination angle conditions was very low at 0.05 mm(3)/million cycles. The introduction of microseparation to the standard gait cycle increased the mean wear rates to 0.13 mm(3)/million cycles for the cup inclination angle of 55° and 0.11 mm(3)/million cycles for that of 65°. The level of increased wear with microseparation was not dependent on cup angle. A stripe of wear on the head also formed, with corresponding superior rim wear on the cup. The wear rates obtained were low compared to the HIPed third generation alumina ceramic (BIOLOX® forte) tested under the same adverse conditions (1.84 mm(3)/million cycles). BIOLOX® delta has shown lower wear than previous ceramic materials used in THR under adverse conditions.


Journal of Bone and Joint Surgery-british Volume | 2009

Ceramic-on-metal bearings in total hip replacement: whole blood metal ion levels and analysis of retrieved components.

Graham Isaac; Claire Brockett; A. Breckon; D van der Jagt; Sophie Williams; Catherine Hardaker; John Fisher; A. Schepers

This study reports on ceramic-on-metal (CoM) bearings in total hip replacement. Whole blood metal ion levels were measured. The median increase in chromium and cobalt at 12 months was 0.08 microg/1 and 0.22 microg/1, respectively, in CoM bearings. Comparable values for metal-on-metal (MoM) were 0.48 microg/1 and 0.32 microg/1. The chromium levels were significantly lower in CoM than in MoM bearings (p = 0.02). The cobalt levels were lower, but the difference was not significant. Examination of two explanted ceramic heads revealed areas of thin metal transfer. CoM bearings (one explanted head and acetabular component, one explanted head and new acetabular component, and three new heads and acetabular components) were tested in a hip joint simulator. The explanted head and acetabular component had higher bedding-in. However, after one million cycles all the wear rates were the same and an order of magnitude less than that reported for MoM bearings. There were four outliers in each clinical group, primarily related to component malposition.

Collaboration


Dive into the Sophie Williams's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge