Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Verena Ruhlmann is active.

Publication


Featured researches published by Verena Ruhlmann.


European Journal of Nuclear Medicine and Molecular Imaging | 2015

[ 18 F]FDG PET/MRI vs. PET/CT for whole-body staging in patients with recurrent malignancies of the female pelvis: initial results

Karsten Beiderwellen; Johannes Grueneisen; Verena Ruhlmann; Paul Buderath; Bahriye Aktas; Philipp Heusch; Oliver Kraff; Michael Forsting; Tc Lauenstein; Lale Umutlu

PurposeTo evaluate the diagnostic potential of PET/MRI with [18F]FDG in recurrent ovarian and cervical cancer in comparison to PET/CT.MethodsA group of 19 patients with suspected recurrence of pelvic malignancies (ovarian cancer, 11 patients; cervical cancer, 8 patients) scheduled for an [18F]FDG PET/CT were subsequently enrolled for a PET/MRI. The scan protocol comprised: (1) a T1-W axial VIBE after contrast agent adminstration, (2) an axial T2-W HASTE, (3) a coronal TIRM, (4) an axial DWI, and dedicated MR sequences of the female pelvis including (5) a T1-W VIBE before contrast agent adminstration, (6) a sagittal T2-W TSE, and (7) a sagittal T1-W dynamic VIBE. The datasets (PET/CT, PET/MRI) were rated separately by two readers regarding lesion count, lesion localization, lesion conspicuity (four-point scale), lesion characterization (benign/malignant/indeterminate) and diagnostic confidence (three-point scale). All available data (histology, prior examinations, PET/CT, PET/MRI, follow-up examinations) served as standard of reference. Median values were compared using the Wilcoxon rank sum test.ResultsMetastatic lesions were present in 16 of the 19 patients. A total of 78 lesions (malignant, 58; benign, 20) were described. Both PET/CT and PET/MRI allowed correct identification of all malignant lesions and provided equivalent conspicuity (3.86 ± 0.35 for PET/CT, 3.91 ± 0.28 for PET/MRI; p > 0.05). Diagnostic confidence was significantly higher for PET/MRI in malignant (p < 0.01) and benign lesions (p < 0.05).ConclusionBoth PET/CT and PET/MRI offer an equivalently high diagnostic value for recurrent pelvic malignancies. PET/MRI offers higher diagnostic confidence in the discrimination of benign and malignant lesions. Considering the reduced radiation dose and superior lesion discrimination, PET/MRI may serve as a powerful alternative to PET/CT in the future.


European Journal of Radiology | 2015

Implementation of FAST-PET/MRI for whole-body staging of female patients with recurrent pelvic malignancies: A comparison to PET/CT

Johannes Grueneisen; Benedikt Michael Schaarschmidt; Martin Heubner; Saravanabavaan Suntharalingam; Ines Milk; Sonja Kinner; Antonia Heubner; Michael Forsting; Tc Lauenstein; Verena Ruhlmann; Lale Umutlu

OBJECTIVES To compare the diagnostic competence of FAST-PET/MRI and PET/CT for whole-body staging of female patients suspect for a recurrence of a pelvic malignancy. METHODS 24 female patients with a suspected tumor recurrence underwent a PET/CT and subsequent PET/MRI examination. For PET/MRI readings a whole-body FAST-protocol was implemented. Two readers separately evaluated the PET/CT and FAST PET/MRI datasets regarding identification of all tumor lesions and qualitative assessment of visual lesion-to-background contrast (4-point ordinal scale). RESULTS Tumor relapse was present in 21 of the 24 patients. Both, PET/CT and PET/MRI allowed for correct identification of tumor recurrence in 20 of 21 cases. Lesion-based sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy for the detection of malignant lesions were 82%, 91%, 97%, 58% and 84% for PET/CT and 85%, 87%, 96%, 63% and 86% for PET/MRI, lacking significant differences. Furthermore, no significant difference for lesion-to-background contrast of malignant and benign lesions was found. CONCLUSION FAST-PET/MRI provides a comparably high diagnostic performance for restaging gynecological cancer patients compared to PET/CT with slightly prolonged scan duration, yet enabling a markedly reduced radiation exposure.


PLOS ONE | 2014

Correlation of Standardized Uptake Value and Apparent Diffusion Coefficient in Integrated Whole-Body PET/MRI of Primary and Recurrent Cervical Cancer

Johannes Grueneisen; Karsten Beiderwellen; Philipp Heusch; Paul Buderath; Bahriye Aktas; Marcel Gratz; Michael Forsting; Thomas C. Lauenstein; Verena Ruhlmann; Lale Umutlu

Background To evaluate a potential correlation of the maximum standard uptake value (SUVmax) and the minimum apparent diffusion coefficient (ADCmin) in primary and recurrent cervical cancer based on integrated PET/MRI examinations. Methods 19 consecutive patients (mean age 51.6 years; range 30–72 years) with histopathologically confirmed primary cervical cancer (n = 9) or suspected tumor recurrence (n = 10) were prospectively enrolled for an integrated PET/MRI examination. Two radiologists performed a consensus reading in random order, using a dedicated post-processing software. Polygonal regions of interest (ROI) covering the entire tumor lesions were drawn into PET/MR images to assess SUVmax and into ADC parameter maps to determine ADCmin values. Pearson’s correlation coefficients were calculated to assess a potential correlation between the mean values of ADCmin and SUVmax. Results In 15 out of 19 patients cervical cancer lesions (n = 12) or lymph node metastases (n = 42) were detected. Mean SUVmax (12.5±6.5) and ADCmin (644.5±179.7×10−5 mm2/s) values for all assessed tumor lesions showed a significant but weak inverse correlation (R = −0.342, p<0.05). When subdivided in primary and recurrent tumors, primary tumors and associated primary lymph node metastases revealed a significant and strong inverse correlation between SUVmax and ADCmin (R = −0.692, p<0.001), whereas recurrent cancer lesions did not show a significant correlation. Conclusions These initial results of this emerging hybrid imaging technique demonstrate the high diagnostic potential of simultaneous PET/MR imaging for the assessment of functional biomarkers, revealing a significant and strong correlation of tumor metabolism and higher cellularity in cervical cancer lesions.


PLOS ONE | 2015

Accuracy of [18F]FDG PET/MRI for the Detection of Liver Metastases

Karsten Beiderwellen; Llanos Geraldo; Verena Ruhlmann; Philipp Heusch; Benedikt Gomez; Felix Nensa; Lale Umutlu; Tc Lauenstein

Background The aim of this study was to compare the diagnostic accuracy of [18F]FDG-PET/MRI with PET/CT for the detection of liver metastases. Methods 32 patients with solid malignancies underwent [18F]FDG-PET/CT and subsequent PET/MRI of the liver. Two readers assessed both datasets regarding lesion characterization (benign, indeterminate, malignant), conspicuity and diagnostic confidence. An imaging follow-up (mean interval: 185±92 days) and/-or histopathological specimen served as standards of reference. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for both modalities. Accuracy was determined by calculating the area under the receiver operating characteristic (ROC) curve. Values of conspicuity and diagnostic confidence were compared using Wilcoxon-signed-rank test. Results The standard of reference revealed 113 liver lesions in 26 patients (malignant: n = 45; benign: n = 68). For PET/MRI a higher accuracy (PET/CT: 82.4%; PET/MRI: 96.1%; p<0.001) as well as sensitivity (67.8% vs. 92.2%, p<0.01) and NPV (82.0% vs. 95.1%, p<0.05) were observed. PET/MRI offered higher lesion conspicuity (PET/CT: 2.0±1.1 [median: 2; range 0–3]; PET/MRI: 2.8±0.5 [median: 3; range 0–3]; p<0.001) and diagnostic confidence (PET/CT: 2.0±0.8 [median: 2; range: 1–3]; PET/MRI 2.6±0.6 [median: 3; range: 1–3]; p<0.001). Furthermore, PET/MRI enabled the detection of additional PET-negative metastases (reader 1: 10; reader 2: 12). Conclusions PET/MRI offers higher diagnostic accuracy compared to PET/CT for the detection of liver metastases.


The Journal of Nuclear Medicine | 2016

Comparative Performance of ¹⁸F-FDG PET/MRI and ¹⁸F-FDG PET/CT in Detection and Characterization of Pulmonary Lesions in 121 Oncologic Patients.

L Sawicki; Johannes Grueneisen; Christian Buchbender; Benedikt Michael Schaarschmidt; Benedikt Gomez; Verena Ruhlmann; Axel Wetter; Lale Umutlu; Gerald Antoch; Philipp Heusch

Our objective was to compare 18F-FDG PET/MRI (performed using a contrast-enhanced T1-weighted fat-suppressed volume-interpolated breath-hold examination [VIBE]) with 18F-FDG PET/CT for detecting and characterizing lung lesions in oncologic patients. Methods: In 121 oncologic patients with 241 lung lesions, PET/MRI was performed after PET/CT in a single-injection protocol (260 ± 58 MBq of 18F-FDG). The detection rates were computed for MRI, the PET component of PET/CT, and the PET component of PET/MRI in relation to the CT component of PET/CT. Wilcoxon testing was used to assess differences in lesion contrast (4-point scale) and size between morphologic datasets and differences in image quality (4-point scale), SUVmean, SUVmax, and characterization (benign/malignant) between PET/MRI and PET/CT. Correlation was determined using the Pearson coefficient (r) for SUV and size and the Spearman rank coefficient (ρ) for contrast. Results: The detection rates for MRI, the PET component of PET/CT, and the PET component of PET/MRI were 66.8%, 42.7%, and 42.3%, respectively. There was a strong correlation in size (r = 0.98) and SUV (r = 0.91) and a moderate correlation in contrast (ρ = 0.48). Image quality was better for PET/CT than for PET/MRI (P < 0.001). Lesion measurements were smaller for MRI than for CT (P < 0.001). SUVmax and SUVmean were significantly higher for PET/MRI than for PET/CT (P < 0.001 each). There was no significant difference in lesion contrast (P = 0.11) or characterization (P = 0.076). Conclusion: In the detection and characterization of lung lesions 10 mm or larger, 18F-FDG PET/MRI and 18F-FDG PET/CT perform comparably. Lesion size, SUV and characterization correlate strongly between the two modalities. However, the overall detection rate of PET/MRI remains inferior to that of PET/CT because of the limited ability of MRI to detect lesions smaller than 10 mm. Thus, thoracic staging with PET/MRI bears a risk of missing small lung metastases.


PLOS ONE | 2015

Correlation of the Apparent Diffusion Coefficient (ADC) with the Standardized Uptake Value (SUV) in Lymph Node Metastases of Non-Small Cell Lung Cancer (NSCLC) Patients Using Hybrid 18F-FDG PET/MRI

Benedikt Michael Schaarschmidt; Christian Buchbender; Felix Nensa; Johannes Grueneien; Benedikt Gomez; Jens Köhler; Henning Reis; Verena Ruhlmann; Lale Umutlu; Philipp Heusch

Objective To compare the apparent diffusion coefficient (ADC) in lymph node metastases of non-small cell lung cancer (NSCLC) patients with standardized uptake values (SUV) derived from combined 18F-fluoro-deoxy-glucose-positron emission tomography/magnetic resonance imaging (18F-FDG PET/MRI). Material and Methods 38 patients with histopathologically proven NSCLC (mean age 60.1 ± 9.5y) received whole-body PET/CT (Siemens mCT™) 60min after injection of a mean dose of 280 ± 50 MBq 18F-FDG and subsequent PET/MRI (mean time after tracer injection: 139 ± 26 min, Siemens Biograph mMR). During PET acquisition, simultaneous diffusion-weighted imaging (DWI, b values: 0, 500, 1000 s/mm²) was performed. A maximum of 10 lymph nodes per patient suspicious for malignancy were analyzed. Regions of interest (ROI) were drawn covering the entire lymph node on the attenuation-corrected PET-image and the monoexponential ADC-map. According to histopathology or radiological follow-up, lymph nodes were classified as benign or malignant. Pearson’s correlation coefficients were calculated for all lymph node metastases correlating SUVmax and SUVmean with ADCmean. Results A total of 146 suspicious lymph nodes were found in 25 patients. One hundred lymph nodes were eligible for final analysis. Ninety-one lymph nodes were classified as malignant and 9 as benign according to the reference standard. In malignant lesions, mean SUVmax was 9.1 ± 3.8 and mean SUVmean was 6.0 ± 2.5 while mean ADCmean was 877.0 ± 128.6 x10-5 mm²/s in PET/MRI. For all malignant lymph nodes, a weak, inverse correlation between SUVmax and ADCmean as well as SUVmean and ADCmean (r = -0.30, p<0.05 and r = -0.36, p<0.05) existed. Conclusion The present data show a weak inverse correlation between increased glucose-metabolism and cellularity in lymph node metastases of NSCLC patients. 18F-FDG-PET and DWI thus may offer complementary information for the evaluation of treatment response in lymph node metastases of NSCLC.


The Journal of Nuclear Medicine | 2016

Evaluation of the Outcome of Lung Nodules Missed on 18F-FDG PET/MRI Compared with 18F-FDG PET/CT in Patients with Known Malignancies

L Sawicki; Johannes Grueneisen; Christian Buchbender; Benedikt Michael Schaarschmidt; Benedikt Gomez; Verena Ruhlmann; Lale Umutlu; Gerald Antoch; Philipp Heusch

The lower detection rate of 18F-FDG PET/MRI than 18F-FDG PET/CT regarding small lung nodules should be considered in the staging of malignant tumors. The purpose of this study was to evaluate the outcome of these small lung nodules missed by 18F-FDG PET/MRI. Methods: Fifty-one oncologic patients (mean age ± SD, 56.6 ± 14.0 y; 29 women, 22 men; tumor stages, I [n = 7], II [n = 7], III [n = 9], IV [n = 28]) who underwent 18F-FDG PET/CT and subsequent 18F-FDG PET/MRI on the same day were retrospectively enrolled. Images were analyzed by 2 interpreters in random order and separate sessions with a minimum of 4 wk apart. A maximum of 10 lung nodules was identified for each patient on baseline imaging. The presence, size, and presence of focal tracer uptake was noted for each lung nodule detected on 18F-FDG PET/CT and 18F-FDG PET/MRI using a postcontrast T1-weighted 3-dimensional gradient echo volume-interpolated breath-hold examination sequence with fat suppression as morphologic dataset. Follow-up CT or 18F-FDG PET/CT (mean time to follow-up, 11 mo; range, 3–35 mo) was used as a reference standard to define each missed nodule as benign or malignant based on changes in size and potential new tracer uptake. Nodule-to-nodule comparison between baseline and follow-up was performed using descriptive statistics. Results: Out of 134 lung nodules found on 18F-FDG PET/CT, 18F-FDG PET/MRI detected 92 nodules. Accordingly, 42 lung nodules (average size ± SD, 3.9 ± 1.3 mm; range, 2–7 mm) were missed by 18F-FDG PET/MRI. None of the missed lung nodules presented with focal tracer uptake on baseline imaging or follow-up 18F-FDG PET/CT. Thirty-three out of 42 missed lung nodules (78.6%) in 26 patients were rated benign, whereas 9 nodules (21.4%) in 4 patients were rated malignant. As a result, 1 patient required upstaging from tumor stage I to IV. Conclusion: Although most small lung nodules missed on 18F-FDG PET/MRI were found to be benign, there was a relevant number of undetected metastases. However, in patients with advanced tumor stages the clinical impact remains controversial as upstaging is usually more relevant in lower stages.


The Journal of Nuclear Medicine | 2016

High Level of Agreement Between Pretherapeutic 124I PET and Intratherapeutic 131I Imaging in Detecting Iodine-Positive Thyroid Cancer Metastases

Marcus Ruhlmann; Walter Jentzen; Verena Ruhlmann; Cinzia Pettinato; Gloria Rossi; Ina Binse; Andreas Bockisch; Sandra Rosenbaum-Krumme

The aim of this retrospective study was to assess the level of agreement between PET and scintigraphy using diagnostic amounts of 124I and therapeutic amounts of 131I, respectively, in detecting iodine-positive metastases in patients with differentiated thyroid carcinoma. Methods: The study included patients who underwent PET/CT 24 and 120 h after administration of approximately 25 MBq of 124I and subsequently underwent imaging 5–10 d after administration of 1–10 GBq of 131I. For each patient, the intratherapeutic 131I imaging comprised a whole-body scintigraphy scan and a SPECT/CT scan of the neck to distinguish between metastatic and thyroid remnant tissues. Iodine uptake was rated as a metastatic focus if located outside the thyroid bed. Lesion- and patient-based analyses were performed. Results: The study included 137 patients with 227 metastases iodine-positive on both functional imaging modalities. In the lesion-based analysis, 124I PET and 131I imaging detected 98% (223/227) and 99% (225/227) of the iodine-positive metastases, respectively; the level of agreement between 124I PET and 131I imaging was 97% (221/227). Four metastases (3 lymph node and 1 bone) in 4 patients were 124I-negative but 131I-positive, and 2 lymph node metastases in 2 patients were 131I-negative but 124I-positive. In the patient-based analysis, 61 of the 137 patients presented with iodine-positive metastases. 124I PET and 131I imaging detected at least one iodine-positive metastasis in 97% (59/61) and 98% (60/61) of the patients, respectively. The level of agreement was 95% (58/61). Both imaging modalities concordantly identified 76 of 137 patients without pathologic iodine uptake. Conclusion: Because of the high level of agreement, pretherapeutic 124I PET/CT is an adequate methodology in the detection of iodine-positive metastases and can be used as a reliable tool for staging of thyroid cancer patients and individualized treatment planning.


PLOS ONE | 2016

Evaluation of a Fast Protocol for Staging Lymphoma Patients with Integrated PET/MRI

Johannes Grueneisen; L Sawicki; Benedikt Michael Schaarschmidt; Saravanabavaan Suntharalingam; Sara von der Ropp; Axel Wetter; Verena Ruhlmann; Harald H. Quick; Michael Forsting; Lale Umutlu

Background The aim of this study was to assess the applicability of a fast MR-protocol for whole-body staging of lymphoma patients using an integrated PET/MR system. Methods A total of 48 consecutive lymphoma patients underwent 52 clinically indicated PET/CT and subsequent PET/MRI examinations with the use of 18F-FDG. For PET/MR imaging, a fast whole-body MR-protocol was implemented. A radiologist and a nuclear medicine physician interpreted MRI and PET/MRI datasets in consensus and were instructed to identify manifestations of lymphoma on a site-specific analysis. The accuracy for the identification of active lymphoma disease was calculated and the tumor stage for each examination was determined. Furthermore, radiation doses derived from administered tracer activities and CT protocol parameters were estimated and the mean scan duration of PET/CT and PET/MR imaging was determined. Statistical analysis was performed to compare the diagnostic performance of PET/MRI and MRI alone. The results of PET/CT imaging, all available histopathological samples as well as results of prior examinations and follow-up imaging were used for the determination of the reference standard. Results Active lymphoma disease was present in 28/52 examinations. PET/MRI revealed higher values of diagnostic accuracy for the identification of active lymphoma disease in those 52 examinations in comparison to MRI, however, results of the two ratings did not differ significantly. On a site specific analysis, PET/MRI showed a significantly higher accuracy for the identification of nodal manifestation of lymphoma (p<0.05) if compared to MRI, whereas ratings for extranodal regions did not reveal a significant difference. In addition, PET/MRI enabled correct identification of lymphoma stage in a higher percentage of patients than MRI (94% vs. 83%). Furthermore, SUVs derived from PET/MRI were significantly higher than in PET/CT, however, there was a strong positive correlation between SUVmax and SUVmean of the two imaging modalities (R = 0.91 p<0.001 and R = 0.87, p<0.001). Average scan duration of whole-body PET/CT and PET/MRI examinations amounted to 17.3±1.9 min and 27.8±3.7 min, respectively. Estimated mean effective-dose for whole-body PET/CT scans were 64.4% higher than for PET/MRI. Conclusions Our results demonstrate the usefulness of 18F-FDG PET data as a valuable additive to MRI for a more accurate evaluation of patients with lymphomas. With regard to patient comfort related to scan duration and a markedly reduced radiation exposure, fast PET/MRI may serve as a powerful alternative to PET/CT for a diagnostic workup of lymphoma patients.


European Journal of Radiology | 2016

Hybrid imaging for detection of carcinoma of unknown primary: A preliminary comparison trial of whole-body PET/MRI versus PET/CT

Verena Ruhlmann; Marcus Ruhlmann; Alexander Bellendorf; Johannes Grueneisen; L Sawicki; Hong Grafe; Michael Forsting; Andreas Bockisch; Lale Umutlu

PURPOSE The aim of this study is to evaluate and compare the diagnostic potential of integrated whole-body [18F]FDG-PET/MRI to [18F]FDG-PET/CT for detection of a potential primary cancer and metastases in patients suspected for cancer of unknown primary (CUP). METHODS A total of 20 patients (15 male, 5 female, age 53±13 years) suspect for CUP underwent a dedicated head and neck & whole-body [18F]FDG-PET/CT (Biograph mCT 128, Siemens Healthcare) and a subsequent simultaneous [18F]FDG-PET/MRI examination (Biograph mMR, Siemens Healthcare). Two readers rated the datasets (PET/CT; PET/MRI) regarding the detection of the primary cancer and metastases, lesion conspicuity (4-point ordinal scale) and diagnostic confidence (3-point ordinal scale). PET analysis comprised the assessment of maximum standardized uptake values (SUVmax) of all PET-positive lesions using volume of interest (VOI) analysis derived from the PET/CT and PET/MR datasets. All available data considering histology and imaging including prior and clinical follow-up examinations served as reference standard. Statistical analysis included comparison of mean values using Mann-Whitney U test and correlation of SUVmax using Pearsons correlation. RESULTS In 14 out of 20 patients 49 malignant lesions were present. The primary cancer could be correctly identified in 11/20 patients with both PET/CT and PET/MRI. PET/CT enabled the detection of a total 38 metastases, PET/MR respectively of 37 metastases (one lung metastasis <5mm was missed). PET/CT and PET/MRI showed comparably high lesion conspicuity (2.6±0.6 each), with superior assessment of cervical lesions in PET/MRI and an indicated superior assessment of pulmonary lesions in PET/CT. Diagnostic confidence was rated comparably high in PET/CT and PET/MRI (2.7±0.5 each). The mean values of SUVmax of all PET-positive lesions (PET/MRT 7.9±4.2 vs. PET/CT 7.2±3.5) showed a strong positive correlation between the SUVs derived from both hybrid imaging systems (Pearsons correlation r=0.927). CONCLUSIONS Both hybrid imaging techniques provide a comparable diagnostic ability for detection of primary cancer and metastases in patients with CUP, with comparably high lesion conspicuity and diagnostic confidence, offering superior assessment of cervical lesions in PET/MRI and potentially of pulmonary lesions in PET/CT. Furthermore, due to the significantly lower dose of ionizing radiation, PET/MRI may serve as a powerful alternative to PET/CT, particularly for therapy monitoring and/or surveillance considering the long-term cumulative dose.

Collaboration


Dive into the Verena Ruhlmann's collaboration.

Top Co-Authors

Avatar

Lale Umutlu

University of Duisburg-Essen

View shared research outputs
Top Co-Authors

Avatar

Philipp Heusch

University of Düsseldorf

View shared research outputs
Top Co-Authors

Avatar

Johannes Grueneisen

University of Duisburg-Essen

View shared research outputs
Top Co-Authors

Avatar

Gerald Antoch

University of Düsseldorf

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Michael Forsting

University of Duisburg-Essen

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Benedikt Gomez

University of Duisburg-Essen

View shared research outputs
Top Co-Authors

Avatar

L Sawicki

University of Düsseldorf

View shared research outputs
Top Co-Authors

Avatar

Karsten Beiderwellen

University of Duisburg-Essen

View shared research outputs
Researchain Logo
Decentralizing Knowledge