Ana Rosa Costa
State University of Campinas
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Ana Rosa Costa.
Brazilian Dental Journal | 2009
Rogério Vieira Reges; Ana Rosa Costa; Américo Bortolazzo Correr; Evandro Piva; Regina Maria Puppin-Rontani; Mário Alexandre Coelho Sinhoreti; Lourenço Correr-Sobrinho
The aim of this study was to evaluate the Knoop hardness after 15 min and 24 h of different shades of a dual-cured resin-based cement after indirect photoactivation (ceramic restoration) with 2 light-curing units (LCUs). The resin cement Variolink II (Ivoclar Vivadent) shade XL, A2, A3 and opaque were mixed with the catalyst paste and inserted into a black Teflon mold (5 mm diameter x 1 mm high). A transparent strip was placed over the mold and a ceramic disc (Duceram Plus, shade A3) was positioned over the resin cement. Light-activation was performed through the ceramic for 40 s using quartz-tungsten-halogen (QTH) (XL 2500; 3M ESPE) or light-emitting diode (LED) (Ultrablue Is, DMC) LCUs with power density of 615 and 610 mW/cm(2), respectively. The Koop hardness was measured using a microhardness tester HMV 2 (Shimadzu) after 15 min or 24 h. Four indentations were made in each specimen. Data were subjected to ANOVA and Tukeys test (alpha=0.05). The QTH LCU provided significantly higher (p<0.05) KHN values than the LED LCU. When the post-cure times were compared for the same shade, QTH and LED at 24 h provided significantly higher (p<0.05) KHN values than at 15 min. It may be concluded that the Knoop hardness was generally dependent on the LCU and post-cure time. The opaque shade of the resin cement showed lower Knoop hardness than the other shades for both LCUs and post-cure times.
Brazilian Dental Journal | 2011
Paulo Roberto Amaral Gonçalves; Rafael R. Moraes; Ana Rosa Costa; Américo Bortolazzo Correr; Paulo Roberto Aranha Nouer; Mário Alexandre Coelho Sinhoreti; Lourenço Correr-Sobrinho
This study evaluated the bond strength of brackets to ceramic testing different etching times and light sources for photo-activation of the bonding agent. Cylinders of feldspathic ceramic were etched with 10% hydrofluoric acid for 20 or 60 s. After application of silane on the ceramic surface, metallic brackets were bonded to the cylinders using Transbond XT (3M Unitek). The specimens for each etching time were assigned to 4 groups (n=15), according to the light source: XL2500 halogen light, UltraLume 5 LED, AccuCure 3000 argon laser, and Apollo 95E plasma arc. Light-activation was carried out with total exposure times of 40, 40, 20 and 12 s, respectively. Shear strength testing was carried out after 24 h. The adhesive remnant index (ARI) was evaluated under magnification. Data were subjected to two-way ANOVA and Tukeys test (α=0.05). Specimens etched for 20 s presented significantly lower bond strength (p<0.05) compared with those etched for 60 s. No significant differences (p>0.05) were detected among the light sources. The ARI showed a predominance of scores 0 in all groups, with an increase in scores 1, 2 and 3 for the 60 s time. In conclusion, only the etching time had significant influence on the bond strength of brackets to ceramic.
Brazilian Dental Journal | 2011
Ana Rosa Costa; Américo Bortolazzo Correr; Regina Maria Puppin-Rontani; Silvia Amélia Scudeler Vedovello; Heloísa Cristina Valdrighi; Lourenço Correr-Sobrinho; Mário Vedovello Filho
This study evaluated the effects of thermocycling and different light sources on the bond strength of metallic brackets to bovine tooth enamel using an adhesive resin. Bovine teeth were etched with 35% phosphoric acid gel for 20 s. After application of primer, metallic brackets were bonded to the buccal surface using Transbond XT, forming 8 groups (n = 20), depending on the light source used for photoactivation (AccuCure 3000 argon laser--20 s, Apollo 95E plasma arc--12 s, UltraLume 5 LED--40 s and XL2500 halogen light--40 s) and experimental conditions without (Groups 1 to 4) or with thermocycling (Groups 5 to 8). Shear bond testing was carried out after 24 h of distilled water storage (Groups 1 to 4) or storage and thermocycling in distilled water (groups 5 to 8; 1,500 cycles--5°/55 °C). Data were subjected to two-way ANOVA and Tukeys test (α = 0.05). The Adhesive Remnant Index (ARI) was evaluated at ×8 magnification. No significant differences (p>0.05) in bond strength were found when the conditions without and with thermocycling were compared for any of the light sources. No significant differences (p>0.05) in bond strength were found among the light sources, irrespective of performing or not thermocycling. There was a predominance of ARI scores 1 in all groups. In conclusion, light sources and thermocycling had no influence on the bond strength of brackets to bovine enamel.
Brazilian Dental Journal | 2012
Ana Rosa Costa; Américo Bortolazzo Correr; Regina Maria Puppin-Rontani; Silvia Amélia Scudeler Vedovello; Heloísa Cristina Valdrighi; Lourenço Correr-Sobrinho; Mário Vedovello Filho
The purpose of this study was to evaluate the bond strength of metallic orthodontic brackets to feldspathic ceramic with different etching times, bonding materials and with or without silane application. Cylinders of feldspathic ceramic were etched with 10% hydrofluoric acid for 20 or 60 s. For each etching time, half of the cylinders received two layers of silane. Metallic brackets were bonded to the cylinders using Transbond XT (3M Unitek) or Fuji Ortho LC (GC). Light-activation was carried out with total exposure time of 40 s using UltraLume 5. Shear bond strength testing was performed after 24 h storage. Data were submitted to three-way ANOVA and Tukeys test (α=0.05). The adhesive remnant index (ARI) was used to evaluate the amount of adhesive remaining on the ceramic surface at ×8 magnification. Specimens etched for 60 s had significantly higher bond strength compared with 20 s. The application of silane was efficient in increasing the shear bond strength between ceramic and both fixed materials. Transbond XT showed significantly higher (p<0.05) bond strength than Fuji Orth LC. There was a predominance of ARI score 0 (clean ceramic failure surface) for all groups, with an increase in scores 1, 2 and 3 (adhesive material increasingly present on ceramic failure aspect) for the 60-s etching time. In conclusion, 60-s etching time, silane and Transbond XT improved significantly the shear bond strength of brackets to ceramic.
Brazilian Dental Journal | 2010
Eduardo Dall'Magro; Américo Bortolazzo Correr; Ana Rosa Costa; Gisele Maria Correr; Rafael Leonardo Xediek Consani; Lourenço Correr-Sobrinho; Mário Alexandre Coelho Sinhoreti
Using the push-out test, this study evaluated the bond strength of the composite resin Z250 (3M/ESPE) photoactivated with the XL2500 (3M/ESPE) quartz-tungsten-halogen light-curing unit with different curing protocols: soft-start (150 mW/cm² for 2 s (S2), 3 s (S3), 5 s (S5), 10 s (S10) or 15 s (S15), followed by 700 mW/cm² for 15 s; pulse-delay (150 mW/cm² for 2 s (P2), 3 s (P3), 5 s (P5), 10 s (P10) or 15 s (P15), with a 1-min delay, followed by 700 mW/cm² for 15 s. After storage at 37°C ± 1 for 24 h ± 1, the specimens were ground, polished and subjected to a push-out test in a universal test machine (Instron) with a cell load of 500 N at a crosshead speed of 0.5 mm/min. The data were analyzed statistically by ANOVA and Tukeys test at 5% significance level. There were no statistically significant differences (p>0.05) among the groups photoactivated using the soft-start mode. For the pulse-delay mode, P5 promoted the highest bond strength (p<0.05). Groups photoactivated with the pulse-delay mode (except for P2 and P15) presented significantly higher bond strength than those photoactivated with the soft-start. It may be concluded that the influence of initial exposure time was curing method-dependent, with the best results obtained using the pulse-delay method with 5 s in the first photoactivation cycle.
Brazilian Dental Journal | 2014
E.F. Soares; Ana Rosa Costa; Américo Bortolazzo Correr; S. Vedovello; Mário Vedovello Filho; Fabrício Aulo Ogliari; Rafael R. Moraes; Lourenço Correr-Sobrinho
This study investigated the effect of the incorporation of an iodonium salt in experimental composites, on the bond strength of metallic brackets bonded to bovine teeth. Two hundred and seventy bovine teeth were embedded in self-curing acrylic resin and divided into 18 groups (n=15), according to the experimental composite with an iodonium salt at molar concentrations 0 (control), 0.5, or 1%; the light-activation times (8, 20 and 40 s); and the storage times (10 min or 24 h). Metallic brackets were fixed on the tooth surface using experimental composites. Photoactivation was performed with a quartz-tungsten-halogen light-curing unit curing unit for 8, 20 and 40 s. The specimens were stored in distilled water at 37 °C for 10 min or 24 h and submitted to bond strength test at 0.5 mm/min. The data were subjected to three-way ANOVA and Tukeys test (α=0.05). The Adhesive Remnant Index (ARI) was used to classify the failure modes. The shear bond strengths (MPa) at 10 min for light-activation times of 8, 20 and 40 s were: G1 - 4.6, 6.9 and 7.1; G2 - 8.1, 9.2 and 9.9; G3 - 9.1, 10.4 and 10.7; and at 24 h were: G1 - 10.9, 11.1 and 11.7; G2 - 11.8, 12.7 and 14.2; G3 - 12.1, 14.4 and 15.8. There was a predominance of ARI score 3 for groups with 10 min storage time, and ARI score 2 for groups with 24 h storage time. In conclusion, the addition of iodonium salt (C05 and C1) to the experimental composite may increase the bond strength of brackets to bovine enamel using reduced light exposure times.
Brazilian Dental Journal | 2014
Dayane Carvalho Ramos Salles de Oliveira; Camila Batista da Silva; Bruno Vilela Muniz; Maria Cristina Volpato; Ana Rosa Costa; Mário Alexandre Coelho Sinhoreti
The aim of this study was to evaluate the degree of conversion (DC) and the cytotoxicity of photo-cured experimental resin composites containing 4-(N,N-dimethylamino)phenethyl alcohol (DMPOH) combined to the camphorquinone (CQ) compared with ethylamine benzoate (EDAB). The resin composites were mechanically blended using 35 wt% of an organic matrix and 65 wt% of filler loading. To this matrix was added 0.2 wt% of CQ and 0.2 wt% of one of the reducing agents tested. 5x1 mm samples (n=5) were previously submitted to DC measurement and then pre-immersed in complete culture medium without 10% (v/v) bovine serum for 1 h or 24 h at 37 °C in a humidifier incubator with 5% CO2 and 95% humidity to evaluate the cytotoxic effects of experimental resin composites using the MTT assay on immortalized human keratinocytes cells. As a result of absence of normal distribution, the statistical analysis was performed using the nonparametric Kruskal-Wallis to evaluate the cytotoxicity and one-way analysis of variance to evaluate the DC. For multiple comparisons, cytotoxicity statistical analyses were submitted to Student-Newman-Keuls and DC analysis to Tukeys HSD post-hoc test (=0.05). No significant differences were found between the DC of DMPOH (49.9%) and EDAB (50.7%). 1 h outcomes showed no significant difference of the cell viability between EDAB (99.26%), DMPOH (94.85%) and the control group (100%). After 24 h no significant difference were found between EDAB (48.44%) and DMPOH (38.06%), but significant difference was found compared with the control group (p>0.05). DMPOH presented similar DC and cytotoxicity compared with EDAB when associated with CQ.
Brazilian Dental Journal | 2015
Ana Rosa Costa; Américo Bortolazzo Correr; Simonides Consani; Maria Cecília Caldas Giorgi; Silvia Amélia Scudeler Vedovello; Mário Vedovello Filho; Eduardo Cesar Almada Santos; Lourenço Correr-Sobrinho
This study investigated the influence of water storage (24 h and 6 months), and Transbond XT and Fuji Ortho LC bonding materials on the bond strength of metallic brackets bonded to feldspathic ceramic. Four cylinders of feldspathic ceramic were etched with 10% hydrofluoric acid for 60 s. Each cylinder received two layers of silane. Metallic brackets were bonded to the cylinders using Transbond XT or Fuji Ortho LC. Light-activation was carried out with 40 s total exposure time using Bluephase G2. Half the specimens for each bonding materials (n=20) were stored in distilled water at 37 °C for 24 h and the other half for 6 months. Shear bond strength testing was performed after storage times at a crosshead speed of 1 mm/min. The adhesive remnant index (ARI) was used to evaluate the amount of adhesive remaining on the ceramic surface at ×8 magnification. Data were subjected to two-way ANOVA and Tukeys test (p<0.05). Transbond XT showed significantly higher bond strength (p<0.05) than Fuji Ortho LC. Significant differences in bond strength (p<0.05) were found when 24 h and 6 months storage times were compared between materials. ARI showed a predominance of score 0 for all groups, and higher scores at 1, 2 and 3 for 24 h storage time. In conclusion, storage time and bonding materials showed significant influence on the bond strength of brackets to ceramic.
Dental Materials | 2014
Éfani C.F. Banzi; Ana Rosa Costa; Regina Maria Puppin-Rontani; Jegdish Babu; Franklin Garcia-Godoy
OBJECTIVES To evaluate the antimicrobial efficacy of Clearfil SE Protect (CP) and Clearfil SE Bond (CB) after curing and rinsed against five individual oral microorganisms as well as a mixture of bacterial culture prepared from the selected test organisms. METHODS Bacterial suspensions were prepared from single species of Streptococcus mutans, Streptococcus sobrinus, Streptococcus gordonii, Actinomyces viscosus and Lactobacillus lactis, as well as mixed bacterial suspensions from these organisms. Dentin bonding system discs (6 mm×2 mm) were prepared, cured, washed and placed on the bacterial suspension of single species or multispecies bacteria for 15, 30 and 60 min. MTT, Live/Dead bacterial viability (antibacterial effect), and XTT (metabolic activity) assays were used to test the two dentin systems antibacterial effect. All assays were done in triplicates and each experiment repeated at least three times. Data were submitted to ANOVA and Scheffes f-test (5%). RESULTS Greater than 40% bacteria killing was seen within 15 min, and the killing progressed with increasing time of incubation with CP discs. However, a longer (60 min) period of incubation was required by CP to achieve similar antimicrobial effect against mixed bacterial suspension. CB had no significant effect on the viability or metabolic activity of the test microorganisms when compared to the control bacterial culture. CP was significantly effective in reducing the viability and metabolic activity of the test organisms. SIGNIFICANCE The results demonstrated the antimicrobial efficacy of CP both on single and multispecies bacterial culture. CP may be beneficial in reducing bacterial infections in cavity preparations in clinical dentistry.
Journal of Biomechanics | 2013
Aloísio Oro Spazzin; Ana Rosa Costa; Américo Bortolazzo Correr; Rafael Leonardo Xediek Consani; Lourenço Correr-Sobrinho; Mateus Bertolini Fernandes dos Santos
This study evaluated the influence of cross-section geometry of the bar framework on the distribution of static stresses in an overdenture-retaining bar system simulating horizontal misfit and bone loss. Three-dimensional FE models were created including two titanium implants and three cross-section geometries (circular, ovoid or Hader) of bar framework placed in the anterior part of a severely resorbed jaw. One model with 1.4-mm vertical loss of the peri-implant tissue was also created. The models set were exported to mechanical simulation software, where horizontal displacement (10, 50 or 100 μm) was applied simulating the settling of the framework, which suffered shrinkage during the laboratory procedures. The bar material used for the bar framework was a cobalt--chromium alloy. For evaluation of bone loss effect, only the 50-μm horizontal misfit was simulated. Data were qualitatively and quantitatively evaluated using von Mises stress for the mechanical part and maximum principal stress and μ-strain for peri-implant bone tissue given by the software. Stresses were concentrated along the bar and in the join between the bar and cylinder. In the peri-implant bone tissue, the μ-strain was higher in the cervical third. Higher stress levels and μ-strain were found for the models using the Hader bar. The bone loss simulated presented considerable increase on maximum principal stresses and μ-strain in the peri-implant bone tissue. In addition, for the amplification of the horizontal misfit, the higher complexity of the bar cross-section geometry and bone loss increases the levels of static stresses in the peri-implant bone tissue.